Computer-Aided Pulmonary Nodule Detection - Performance of Two CAD Systems at Different CT Dose Levels

被引:20
|
作者
Hein, P. A. [1 ]
Rogalla, P. [1 ]
Klessen, C. [1 ]
Lembcke, A. [1 ]
Romano, V. C. [1 ]
机构
[1] Charite, Inst Radiol, Charite Campus Mitte, D-10117 Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2009年 / 181卷 / 11期
关键词
thorax; neoplasms; CT spiral; computer-aided detection; radiation dose; EARLY LUNG-CANCER; SPIRAL CT; CHEST CT; PRELIMINARY EXPERIENCE; AUTOMATED DETECTION; ASSISTED DETECTION; SCREENING-PROGRAM; MULTIDETECTOR CT; SLICE THICKNESS; BASE-LINE;
D O I
10.1055/s-0028-1109394
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-close computed tomography (ULD-CT) and standard dose CT (SD-CT). Materials and Methods: Multi-slice Computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120 kV tube voltage (I mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Results: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72% and 62% (CAD-1 vs. CAD-2) for SD-CT and with 73% and 56% for ULD-CT. Median false positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83% and 61% for SD-CT and to 89% and 67% for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p > 0.05). Conclusion: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems.
引用
收藏
页码:1056 / 1064
页数:9
相关论文
共 50 条
  • [31] Lung cancer screening with CT: Evaluation of radiologists and different computer assisted detection software (CAD) as first and second readers for lung nodule detection at different dose levels
    Christe, A.
    Leidolt, L.
    Huber, A.
    Steiger, P.
    Szucs-Farkas, Z.
    Roos, J. E.
    Heverhagen, J. T.
    Ebner, L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : E873 - E878
  • [32] Detection and classification performance levels of mammographic masses under different computer-aided detection cueing environments
    Zheng, B
    Swensson, RG
    Golla, S
    Hakim, CM
    Shah, R
    Wallace, L
    Gur, D
    ACADEMIC RADIOLOGY, 2004, 11 (04) : 398 - 406
  • [33] A Comprehensive Review of Performance Metrics for Computer-Aided Detection Systems
    Park, Doohyun
    BIOENGINEERING-BASEL, 2024, 11 (11):
  • [34] Computer aided lung nodule detection on CT data
    Jia, Tong
    Wu, Cheng Dong
    Wei, Ying
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE, PTS 1-4, 2011, 44-47 : 3492 - 3496
  • [35] Absolute ground truth-based validation of computer-aided nodule detection and volumetry in low-dose CT imaging
    D'hondt, Louise
    Kellens, Pieter-Jan
    Torfs, Kwinten
    Bosmans, Hilde
    Bacher, Klaus
    Snoeckx, Annemiek
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 121
  • [36] Computer-Aided Detection of Pulmonary Nodules in Computed Tomography Images: Effect on Observer Performance
    Liu, JiaBao
    Wang, Yu
    Zhang, Fa
    Ren, Fei
    Liu, LiHeng
    He, Wen
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (06) : 1205 - 1211
  • [37] Implementation of combined SVM-algorithm and computer-aided perception feedback for pulmonary nodule detection
    Pietrzyk, Mariusz W.
    Rannou, Didier
    Brennan, Patrick C.
    MEDICAL IMAGING 2012: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2012, 8318
  • [38] Autonomous Detection of Solitary Pulmonary Nodules on CT Images for Computer-Aided Diagnosis
    Wei Ying
    Jia Tong
    Lin Ming-xiu
    2011 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-6, 2011, : 4054 - 4059
  • [39] Incorporation of CAD (computer-aided detection) with thin-slice lung CT in routine 18F-FDG PET/CT imaging read-out protocol for detection of lung nodules
    Bhure, Ujwal
    Cieciera, Matthaus
    Lehnick, Dirk
    Lago, Maria del Sol Perez
    Grunig, Hannes
    Lima, Thiago
    Roos, Justus E.
    Strobel, Klaus
    EUROPEAN JOURNAL OF HYBRID IMAGING, 2023, 7 (01):
  • [40] Commercially Available Computer-Aided Detection System for Pulmonary Nodules on Thin-Section Images Using 64 Detectors-Row CT: Preliminary Study of 48 Cases
    Yanagawa, Masahiro
    Honda, Osamu
    Yoshida, Shigeyuki
    Ono, Yusuke
    Inoue, Atsuo
    Daimon, Tadahisa
    Sumikawa, Hiromitsu
    Mihara, Naoki
    Johkoh, Takeshi
    Tomiyama, Noriyuki
    Nakamura, Hironobu
    ACADEMIC RADIOLOGY, 2009, 16 (08) : 924 - 933