Computer-Aided Pulmonary Nodule Detection - Performance of Two CAD Systems at Different CT Dose Levels

被引:20
|
作者
Hein, P. A. [1 ]
Rogalla, P. [1 ]
Klessen, C. [1 ]
Lembcke, A. [1 ]
Romano, V. C. [1 ]
机构
[1] Charite, Inst Radiol, Charite Campus Mitte, D-10117 Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2009年 / 181卷 / 11期
关键词
thorax; neoplasms; CT spiral; computer-aided detection; radiation dose; EARLY LUNG-CANCER; SPIRAL CT; CHEST CT; PRELIMINARY EXPERIENCE; AUTOMATED DETECTION; ASSISTED DETECTION; SCREENING-PROGRAM; MULTIDETECTOR CT; SLICE THICKNESS; BASE-LINE;
D O I
10.1055/s-0028-1109394
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-close computed tomography (ULD-CT) and standard dose CT (SD-CT). Materials and Methods: Multi-slice Computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120 kV tube voltage (I mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Results: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72% and 62% (CAD-1 vs. CAD-2) for SD-CT and with 73% and 56% for ULD-CT. Median false positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83% and 61% for SD-CT and to 89% and 67% for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p > 0.05). Conclusion: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems.
引用
收藏
页码:1056 / 1064
页数:9
相关论文
共 50 条
  • [11] Computer-aided lung nodule detection based on CT images
    Jia Tong
    Zhao Da-Zhe
    Wei Ying
    Zhu Xin-Hua
    Wang Xu
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 816 - 819
  • [12] A Comparison of Computer-Aided Detection (CAD) Effectiveness in Pulmonary Nodule Identification Using Different Methods of Bone Suppression in Chest Radiographs
    Ronald D. Novak
    Nicholas J. Novak
    Robert Gilkeson
    Bahar Mansoori
    Gunhild E. Aandal
    Journal of Digital Imaging, 2013, 26 : 651 - 656
  • [13] A Comparison of Computer-Aided Detection (CAD) Effectiveness in Pulmonary Nodule Identification Using Different Methods of Bone Suppression in Chest Radiographs
    Novak, Ronald D.
    Novak, Nicholas J.
    Gilkeson, Robert
    Mansoori, Bahar
    Aandal, Gunhild E.
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (04) : 651 - 656
  • [14] Computer-Aided Detection of Pulmonary Nodules based on SVM in Thoracic CT Images
    Eskandarian, Parinaz
    Bagherzadeh, Jamshid
    2015 7TH CONFERENCE ON INFORMATION AND KNOWLEDGE TECHNOLOGY (IKT), 2015,
  • [15] Computer-aided detection in screening CT for pulmonary nodules
    Yuan, R
    Vos, PM
    Cooperberg, PL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (05) : 1280 - 1287
  • [16] Computer-Aided Detection of Lung Nodules: Influence of the Image Reconstruction Kernel for Computer-Aided Detection Performance
    Hwang, Jiyoung
    Chung, Myung Jin
    Bae, Younga
    Shin, Kyung Min
    Jeong, Sun Young
    Lee, Kyung Soo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) : 31 - 34
  • [17] Prospective Pilot Evaluation of Radiologists and Computer-aided Pulmonary Nodule Detection on Ultra-low-Dose CT With Tin Filtration
    Takahashi, Edwin A.
    Koo, Chi Wan
    White, Darin B.
    Lindell, Rebecca M.
    Sykes, Anne-Marie G.
    Levin, David L.
    Kuzo, Ronald S.
    Wolf, Matthias
    Bogoni, Luca
    Carter, Rickey E.
    McCollough, Cynthia H.
    Fletcher, Joel G.
    JOURNAL OF THORACIC IMAGING, 2018, 33 (06) : 396 - 401
  • [18] A novel computer-aided lung nodule detection system for CT images
    Tan, Maxine
    Deklerck, Rudi
    Jansen, Bart
    Bister, Michel
    Cornelis, Jan
    MEDICAL PHYSICS, 2011, 38 (10) : 5630 - 5645
  • [19] Performance Analysis in Children of Traditional and Deep Learning CT Lung Nodule Computer-Aided Detection Systems Trained on Adults
    Hardie, Russell C.
    Trout, Andrew T.
    Dillman, Jonathan R.
    Narayanan, Barath N.
    Tanimoto, Aki A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (02)
  • [20] Performance analysis of a computer-aided detection system for lung nodules in CT at different slice thicknesses
    Narayanan, Barath Narayanan
    Hardie, Russell Craig
    Kebede, Temesguen Messay
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)