Computer-Aided Pulmonary Nodule Detection - Performance of Two CAD Systems at Different CT Dose Levels

被引:20
|
作者
Hein, P. A. [1 ]
Rogalla, P. [1 ]
Klessen, C. [1 ]
Lembcke, A. [1 ]
Romano, V. C. [1 ]
机构
[1] Charite, Inst Radiol, Charite Campus Mitte, D-10117 Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2009年 / 181卷 / 11期
关键词
thorax; neoplasms; CT spiral; computer-aided detection; radiation dose; EARLY LUNG-CANCER; SPIRAL CT; CHEST CT; PRELIMINARY EXPERIENCE; AUTOMATED DETECTION; ASSISTED DETECTION; SCREENING-PROGRAM; MULTIDETECTOR CT; SLICE THICKNESS; BASE-LINE;
D O I
10.1055/s-0028-1109394
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-close computed tomography (ULD-CT) and standard dose CT (SD-CT). Materials and Methods: Multi-slice Computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120 kV tube voltage (I mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Results: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72% and 62% (CAD-1 vs. CAD-2) for SD-CT and with 73% and 56% for ULD-CT. Median false positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83% and 61% for SD-CT and to 89% and 67% for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p > 0.05). Conclusion: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems.
引用
收藏
页码:1056 / 1064
页数:9
相关论文
共 50 条
  • [1] Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume
    Zhao, Yingru
    de Bock, Geertruida H.
    Vliegenthart, Rozemarijn
    van Klaveren, Rob J.
    Wang, Ying
    Bogoni, Luca
    de Jong, Pim A.
    Mali, Willem P.
    van Ooijen, Peter M. A.
    Oudkerk, Matthijs
    EUROPEAN RADIOLOGY, 2012, 22 (10) : 2076 - 2084
  • [2] Small pulmonary nodules:: Effect of two computer-aided detection systems on radiologist performance
    Das, Marco
    Muehlenbruch, Georg
    Mahnken, Andreas H.
    Flohr, Thomas G.
    Guendel, Lutz
    Stanzel, Sven
    Kraus, Thomas
    Guenther, Rolf W.
    Wildberger, Joachim E.
    RADIOLOGY, 2006, 241 (02) : 564 - 571
  • [3] Computer-aided detection and automated CT volumetry of pulmonary nodules
    Marten, Katharina
    Engelke, Christoph
    EUROPEAN RADIOLOGY, 2007, 17 (04) : 888 - 901
  • [4] Computer-aided detection and analysis of pulmonary nodule from CT images: A survey
    Dhara, Ashis Kumar
    Mukhopadhyay, Sudipta
    Khandelwal, Niranjan
    IETE TECHNICAL REVIEW, 2012, 29 (04) : 265 - 275
  • [5] Lung nodule detection on chest CT: Evaluation of a computer-aided detection (CAD) system
    Lee, IJ
    Gamsu, G
    Czum, J
    Wu, N
    Johnson, R
    Chakrapani, S
    KOREAN JOURNAL OF RADIOLOGY, 2005, 6 (02) : 89 - 93
  • [6] Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume
    Yingru Zhao
    Geertruida H. de Bock
    Rozemarijn Vliegenthart
    Rob J. van Klaveren
    Ying Wang
    Luca Bogoni
    Pim A. de Jong
    Willem P. Mali
    Peter M. A. van Ooijen
    Matthijs Oudkerk
    European Radiology, 2012, 22 : 2076 - 2084
  • [7] Pulmonary nodules: Effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system-Comparison of performance between different-dose CT scans
    Yanagawa, Masahiro
    Honda, Osamu
    Kikuyama, Ayano
    Gyobu, Tomoko
    Sumikawa, Hiromitsu
    Koyama, Mitsuhiro
    Tomiyama, Noriyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2877 - 2886
  • [8] Aspects of computer-aided detection (CAD) and volumetry of pulmonary nodules using multislice CT
    Wiemker, R
    Rogalla, P
    Blaffert, T
    Sifri, D
    Hay, O
    Shah, E
    Truyen, R
    Fleiter, T
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 : S46 - S56
  • [9] Performance of Lung Nodule Computer-Aided Detection Systems on Standard-Dose and Low-Dose Pediatric CT Scans: An Intraindividual Comparison
    Hardie, Russell C.
    Trout, Andrew T.
    Dillman, Jonathan R.
    Narayanan, Barath N.
    Tanimoto, Aki A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2025, 224 (01)
  • [10] Computer-aided diagnosis of pulmonary nodules on CT scans: Improvement of classification performance with nodule surface features
    Way, Ted W.
    Sahiner, Berkman
    Chan, Heang-Ping
    Hadjiiski, Lubomir
    Cascade, Philip N.
    Chughtai, Aamer
    Bogot, Naama
    Kazerooni, Ella
    MEDICAL PHYSICS, 2009, 36 (07) : 3086 - 3098