A fluorometric aptamer-based assay for ochratoxin A using magnetic separation and a cationic conjugated fluorescent polymer

被引:17
|
作者
Liu, Yufei [1 ]
Yan, Huijuan [1 ]
Shangguan, Jingfang [1 ]
Yang, Xue [1 ]
Wang, Meili [2 ]
Liu, Wei [1 ]
机构
[1] Xinxiang Med Univ, Sch Pharm, Xinxiang 453003, Henan, Peoples R China
[2] Qual Monitoring Ctr Agr Prod, Pingdingshan 467000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Cationic conjugated fluorescent polymers; Fluorescence resonance energy transfer; Hybridization chain reaction; Ochratoxin B; Aflatoxin B1; Zearalenone; COLORIMETRIC APTASENSOR; SENSITIVE DETECTION; GRAPHENE OXIDE; SMALL-MOLECULE; AMPLIFICATION; IMMUNOASSAY; PLATFORM; DOTS; DNA;
D O I
10.1007/s00604-018-2962-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorometric aptamer-based assay for ochratoxin A (OTA) is described. It is making use of magnetic separation and a cationic conjugated fluorescent polymer. Amino-tagged aptamer (Apt) against OTA is immobilized on magnetic beads (MBs) to form a conjugate of type Apt-MBs. The immobilized aptamer is partially complementary to carboxyfluorescein-labeled DNA which binds to the Apt-MBs via hybridization if OTA is absent. Only few FAM-DNA will remain in the supernatant after magnetic separation, and only weak fluorescence resonance energy transfer (FRET) occurs on addition of the fluorescent polymer. If, however, OTA is present, it will bind to the aptamer and prevent the hybridization between Apt-DNA and FAM-DNA. This results in the presence of large amounts of FAM-DNA in the supernatant after magnetic separation. On addition of fluorescent polymer, efficient FRET occurs from the polymer to FAM-DNA. Fluorescence, best measured at excitation/emission peaks of 370/530 nm, increases with increasing concentrations of OTA. This assay is highly sensitive and selective. The detection limit is as low as 0.11 ng mL(-1). This is 6 times lower than the aptamer assay without using the fluorescent polymer. Conceivably, this method has a wider scope in that it may be extended to other mycotoxins by simply changing the aptamer.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A fluorometric aptamer-based assay for ochratoxin A using magnetic separation and a cationic conjugated fluorescent polymer
    Yufei Liu
    Huijuan Yan
    Jingfang Shangguan
    Xue Yang
    Meili Wang
    Wei Liu
    Microchimica Acta, 2018, 185
  • [2] Aptamer-Based Fluorometric Ochratoxin A Assay Based on Photoinduced Electron Transfer
    Zhao, Han
    Xiang, Xinying
    Chen, Mingjian
    Ma, Changbei
    TOXINS, 2019, 11 (02):
  • [3] Aptamer-based fluorescent assay for determination of ochratoxin A in herbal medicine
    Qin, Meijun
    Guo, Limin
    Geng, Haiqin
    Li, Yun
    Chinese Journal of Analysis Laboratory, 2021, 40 (12): : 1370 - 1375
  • [4] A fluorometric aptamer-based assay for ochratoxin A by using exonuclease III-assisted recycling amplification
    Liu, Mei
    Li, Xuanyi
    Li, Baoxin
    Du, Jianxiu
    Yang, Zongqi
    MICROCHIMICA ACTA, 2020, 187 (01)
  • [5] A fluorometric aptamer-based assay for ochratoxin A by using exonuclease III-assisted recycling amplification
    Mei Liu
    Xuanyi Li
    Baoxin Li
    Jianxiu Du
    Zongqi Yang
    Microchimica Acta, 2020, 187
  • [6] An Aptamer-based Fluorescence Assay for Ochratoxin A
    Duan Nuo
    Wu Shi-Jia
    Wang Zhou-Ping
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (03) : 300 - 304
  • [7] Aptamer-based fluorescent detection of ochratoxin A by quenching of gold nanoparticles
    Lv, Xin
    Zhang, Yuanfu
    Liu, Guofu
    Du, Lingyun
    Wang, Shuhao
    RSC ADVANCES, 2017, 7 (27): : 16290 - 16294
  • [8] Fluorometric aptamer based assay for ochratoxin A based on the use of exonuclease III
    Renjie Liu
    Hua Wu
    Lei Lv
    Xiaojiao Kang
    Chengbi Cui
    Jin Feng
    Zhijun Guo
    Microchimica Acta, 2018, 185
  • [9] Fluorometric aptamer based assay for ochratoxin A based on the use of exonuclease III
    Liu, Renjie
    Wu, Hua
    Lv, Lei
    Kang, Xiaojiao
    Cui, Chengbi
    Feng, Jin
    Guo, Zhijun
    MICROCHIMICA ACTA, 2018, 185 (05)
  • [10] An aptamer-based colorimetric Pt(II) assay based on the use of gold nanoparticles and a cationic polymer
    Sang, Fuming
    Liu, Jia
    Zhang, Xue
    Pan, Jianxin
    MICROCHIMICA ACTA, 2018, 185 (05)