Acute vascular access catheters for haemodialysis: Complications limiting technique survival

被引:11
作者
Jefferys, A [1 ]
Chow, JSF [1 ]
Suranyi, MG [1 ]
机构
[1] Liverpool Hosp, Renal Unit, Sydney, NSW 2170, Australia
关键词
acute haemodialysis access; central venous catheter; haemodialysis catheter; intravascular catheter; temporary haemodialysis access; vascular access catheter;
D O I
10.1046/j.1440-1797.2003.00139.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The use of acute vascular access catheters (AVACs) has facilitated the delivery of haemodialysis to patients lacking functioning access. A review of the experience of a tertiary Australian renal treatment centre, consisting of 205 sequential AVACs in 93 patients, was undertaken over 1 year, to identify issues limiting technique survival. Acute vascular access catheters were inserted as acute dialysis access for patients with chronic renal failure (CRF; 21%), failed grafts or fistulae (18%), acute renal failure (12%), failed chronic ambulatory peritoneal dialysis (CAPD; 8%) or failed prior AVACs (37%). The majority of AVACs were on the right (74%), and the placement site was simple jugular (69%), tunnelled jugular (15%), femoral (12%), or subclavian (4%). During follow up, 198 of 205 AVACs were removed. The mean AVAC survival was superior (P < 0.0001, Fisher's protected least significant difference (PLSD) for tunnelled jugular AVACS (62 +/- 46 (SD) days) compared with simple jugular (20 +/- 19), subclavian (18 +/- 13) and femoral (7 +/- 6). Causes for AVAC removal were: elective (47%), blockage (31%), infection (20%) or cracked catheter (1%). Routine postremoval tip cultures grew coagulase negative Staphylococcus (CNS, 46%), negative culture (33%), methicillin-resistant Staphylococcus aureus (MRSA; 9%), Staphylococcus aureus (9%), Gram-negative rods (1%), Pseudomonas (0.5%) or other uncommon organisms (2%). Blood cultures were drawn through the AVAC in the setting of suspected bacteraemia in 42 of 198 AVACs. Blood cultures were negative in 40%. Positive cultures included Staphylococcus species in 55%: including MRSA (19%), Staphylococcus aureus (29%) and CNS (34%). Rare cultures identified Escherichia coli (2%) or Serratia (2%). Infection and blockage significantly reduced AVAC survival, affecting more than 50% of cases. Approaches to minimize these complications are likely to lead to improved clinical outcomes with AVAC use.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 14 条
[1]  
*CAR AUSTR REN IMP, 2000, GUIDELINES
[2]   Thrombolysis for restoration of patency to haemodialysis central venous catheters:: A systematic review [J].
Clase, CM ;
Crowther, MA ;
Ingram, AJ ;
Cinà, CS .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2001, 11 (02) :127-136
[3]   Outcome and complications of temporary haemodialysis catheters [J].
Kairaitis, LK ;
Gottlieb, T .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1999, 14 (07) :1710-1714
[4]   THE DIAGNOSTIC-VALUE OF COLOR DOPPLER ULTRASOUND IN CENTRAL VENOUS CATHETER-RELATED THROMBOSIS [J].
KOKSOY, C ;
KUZU, A ;
KUTLAY, J ;
ERDEN, I ;
OZCAN, H ;
ERGIN, K .
CLINICAL RADIOLOGY, 1995, 50 (10) :687-689
[5]   Factors affecting haemodialysis-access survival in a single centre retrospective cohort study [J].
Lawrence, C ;
Chow, J ;
Suranyi, M .
NEPHROLOGY, 2002, 7 (02) :72-76
[6]   A prospective study of complications associated with cuffed, tunnelled haemodialysis catheters [J].
Little, MA ;
O'Riordan, A ;
Lucey, B ;
Farrell, M ;
Lee, M ;
Conlon, PJ ;
Walshe, JJ .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (11) :2194-2200
[7]   Comparison of technical success and outcome of tunneled catheters inserted via the jugular and subclavian approaches [J].
Macdonald, S ;
Watt, AJB ;
McNally, D ;
Edwards, RD ;
Moss, JG .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (02) :225-231
[8]   Risk of bacteremia from temporary hemodialysis catheters by site of insertion and duration of use: A prospective study [J].
Oliver, MJ ;
Callery, SM ;
Thorpe, KE ;
Schwab, SJ ;
Churchill, DN .
KIDNEY INTERNATIONAL, 2000, 58 (06) :2543-2545
[9]   USE OF TISSUE-PLASMINOGEN ACTIVATOR FOR REOPENING OF CLOTTED DIALYSIS CATHETERS [J].
PAULSEN, D ;
REISAETHER, A ;
AASEN, M ;
FAUCHALD, P .
NEPHRON, 1993, 64 (03) :468-470
[10]   Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature [J].
Randolph, AG ;
Cook, DJ ;
Gonzales, CA ;
Pribble, CG .
CRITICAL CARE MEDICINE, 1996, 24 (12) :2053-2058