Computer-simulated fluid dynamics of arterial perfusion in extracorporeal circulation: From reality to virtual simulation

被引:13
作者
Fukuda, Ikuo [1 ]
Osanai, Satoshi [2 ]
Shirota, Minori [2 ]
Inamura, Takao [2 ]
Yanaoka, Hideki [2 ]
Minakawa, Masahito [1 ]
Fukui, Kozo [1 ]
机构
[1] Hirosaki Univ, Dept Thorac & Cardiovasc Surg, Grad Sch Med, Hirosaki, Aomori 0368562, Japan
[2] Hirosaki Univ, Fac Sci & Technol, Hirosaki, Aomori 0368562, Japan
关键词
Arterial perfusion; Atheroembolism; Flow dynamics; Numerical simulation; Computation model; AORTIC-ARCH; BLOOD-FLOW; CANNULA; HYDRODYNAMICS; PATTERNS; BYPASS; DESIGN; STROKE;
D O I
10.1177/039139880903200607
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Atheroembolism due to aortic manipulation remains an unsolved problem in surgery for thoracic aortic aneurysm. the goal of the present study is to create a computer simulation (CS) model with which to analyze blood flow in the diseased aorta. Method: a three-dimensional glass model of the aortic arch was constructed from CT images of a normal, healthy person and a patient with transverse aortic arch aneurysm. Separately, a CS model of the curved end-hole cannula was created, and flow from the aortic cannula was recreated using a numerical simulation. Results: Comparison of the data obtained by the glass model analyses revealed that the flow velocity and the vector of the flow around the exit of the cannula were similar to that in the CS model. a high-velocity area was observed around the cannula exit in both the glass model and the CS model. the maximum flow velocity was as large as 1.0 m/s at 20 mm from the cannula exit and remained as large as 0.5 to 0.6 m/s within 50 mm of the exit. In the aortic arch aneurysm models, the rapid jet flow from the cannula moved straight toward the lesser curvature of the transverse aortic arch. the locations and intensities of the calculated vortices were slightly different from those obtained for the glass model. Conclusions: the proposed CS method for the analysis of blood flow from the aortic cannulae during extracorporeal circulation can reproduce the flow velocity and flow pattern in the proximal and transverse aortic arches. (Int J Artif organs 2009; 32: 362-70)
引用
收藏
页码:362 / 370
页数:9
相关论文
共 23 条
  • [1] Stroke in cardiac surgical patients: Determinants and outcome
    Almassi, GH
    Sommers, T
    Moritz, TE
    Shroyer, ALW
    London, MJ
    Henderson, WG
    Sethi, GK
    Grover, FL
    Hammermeister, KE
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (02) : 391 - 398
  • [2] Aortic atheroma is related to outcome but not numbers of emboli during coronary bypass
    Barbut, D
    Lo, YW
    Hartman, GS
    Yao, FSF
    Trifiletti, RR
    Hager, DN
    Hinton, RB
    Gold, JP
    Isom, OW
    [J]. ANNALS OF THORACIC SURGERY, 1997, 64 (02) : 454 - 459
  • [3] MAGNETIC-RESONANCE VELOCITY VECTOR MAPPING OF BLOOD-FLOW IN THORACIC AORTIC-ANEURYSMS AND GRAFTS
    BOGREN, HG
    MOHIADDIN, RH
    YANG, GZ
    KILNER, PJ
    FIRMIN, DN
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (03) : 704 - 714
  • [5] Eagle Kim A, 2004, Circulation, V110, pe340
  • [6] Flow patterns in dog aortic arch under a steady flow condition simulating mid-systole
    Endo, S
    Sohara, Y
    Karino, T
    [J]. HEART AND VESSELS, 1996, 11 (04) : 180 - 191
  • [7] Breakdown of atheromatous plaque due to shear force from arterial perfusion cannula
    Fukuda, Ikuo
    Minakawa, Masahito
    Fukui, Kozo
    Taniguchi, Satoshi
    Daitoku, Kazuyuki
    Suzuki, Yasuyuki
    Hashimoto, Hiroshi
    [J]. ANNALS OF THORACIC SURGERY, 2007, 84 (04) : E17 - E18
  • [8] Hydrodynamics of the new Medos aortic cannula
    Gerdes, A
    Hanke, T
    Sievers, HH
    [J]. PERFUSION-UK, 2002, 17 (03): : 217 - 220
  • [9] Hydrodynamics of aortic arch vessels during perfusion through the right subclavian artery
    Gerdes, A
    Joubert-Hübner, E
    Esders, K
    Sievers, HH
    [J]. ANNALS OF THORACIC SURGERY, 2000, 69 (05) : 1425 - 1430