Balloon-expandable stenting with and without coiling for wide-neck and complex aneurysms

被引:29
作者
Zenteno, Marco
Modenesi Freitas, Jose Maria [1 ]
Aburto-Murrieta, Yolanda
Koppe, Gelson
Machado, Elcio
Lee, Angel
机构
[1] Hosp Evangel, Dept Intervent Radiol, BR-80730150 Curitiba, Parana, Brazil
[2] Inst Nacl Neurol & Neurocirug, Dept Neurol Endovasc Therapy, Mexico City 14269, DF, Mexico
[3] Hosp Santa Rita, Dept Intervent Radiol, BR-04013004 Sao Paulo, Brazil
[4] Hosp Angeles Pedregal, Comprehens Stroke Ctr, Mexico City 10700, DF, Mexico
来源
SURGICAL NEUROLOGY | 2006年 / 66卷 / 06期
关键词
wide-neck aneurysms; stent-supported coiling; solely stenting; endovascular treatment; rate of occlusion;
D O I
10.1016/j.surneu.2006.05.058
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Wide-necked, saccular, dissecting, and fusiform intracranial aneurysms are poor coil retainers. Retention can be improved by parent-artery stenting across the aneurysm. Methods: We used a balloon-expandable stent and delivery system, intending to treat 38 aneurysms in 36 patients. Stents could not be advanced across the neck of 2 aneurysms near the ophthalmic artery origin. These cases were managed by temporary balloon remodeling and coiling. Stenting alone was done for 15 aneurysms, including 7 in vertebral artery V4 segments. Stenting with immediate or delayed coiling was done in 21 aneurysms. Results: Stenting alone caused immediate and complete obliteration of I treated aneurysm (7%), subtotal obliteration in 13 treated (86%) aneurysms, and was associated with I failure. Stenting and coiling yielded a significantly better 57% complete obliteration rate, 43% subtotal obliteration, and no failures. There were 5 complications: I wire perforation, 2 cavernous-carotid-sinus fistulae, and 2 partial in-stent thromboses. All were controlled or cleared with no long-term sequelae or deaths. Contrast imaging at 1 to 12 months was available for 30 patients (13 stent-only, 17 stent-pluscoiling), demonstrating complete obliteration in 25 (83%) and subtotal obliteration in 5. A total of 7 stent-only aneurysms (4 V4s) were completely obliterated, and 3 (all V4s) were; >= 90% obliterated. Conclusion: Stenting and coiling through the wall of the stent resulted in 88% (15/17) complete obliteration when imaged 1 to 12 months after treatment. Stenting alone effectively closed off V4-segment wide-necked aneurysms but was inferior to stenting and coiling in less mobile vessels. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:603 / 610
页数:8
相关论文
共 24 条
[1]  
Akpek S, 2005, AM J NEURORADIOL, V26, P1223
[2]   Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (neuroform) and detachable coils [J].
Benitez, RP ;
Silva, MT ;
Klem, J ;
Veznedaroglu, E ;
Rosenwasser, RH .
NEUROSURGERY, 2004, 54 (06) :1359-1367
[3]  
Cloft HJ, 2000, AM J NEURORADIOL, V21, P1312
[4]  
Derdeyn CP, 2003, AM J NEURORADIOL, V24, P1404
[5]  
Ding YH, 2005, AM J NEURORADIOL, V26, P1757
[6]   Risk factors for subarachnoid hemorrhage - An updated systematic review of epidemiological studies [J].
Feigin, VL ;
Rinkel, GJE ;
Lawes, CMM ;
Algra, A ;
Bennett, DA ;
van Gijn, J ;
Anderson, CS .
STROKE, 2005, 36 (12) :2773-2780
[7]   Stroke epidemiology: a review of population-based studies of incidence, prevalence, and case-fatality in the late 20th century [J].
Feigin, VL ;
Lawes, CMM ;
Bennett, DA ;
Anderson, CS .
LANCET NEUROLOGY, 2003, 2 (01) :43-53
[8]   Usefulness of the neuroform stent for the treatment of cerebral aneurysms: Results at initial (3-6-mo) follow-up [J].
Fiorella, D ;
Albuquerque, FC ;
Deshmukh, VR ;
McDougall, CG .
NEUROSURGERY, 2005, 56 (06) :1191-1201
[9]   Silicon carbide-coated stents in patients with acute coronary syndrome [J].
Hamm, CW ;
Hugenholtz, PG .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (03) :375-381
[10]   Percutaneous intracranial stent placement for aneurysms [J].
Han, PP ;
Albuquerque, FC ;
Ponce, FA ;
MacKay, CI ;
Zabramski, JM ;
Spetzler, RF ;
McDougall, CG .
JOURNAL OF NEUROSURGERY, 2003, 99 (01) :23-30