Improved ceramic-based multisite microelectrode for rapid measurements of L-glutamate in the CNS

被引:173
作者
Burmeister, JJ
Pomerleau, F
Palmer, M
Day, BK
Huettl, P
Gerhardt, GA
机构
[1] Univ Kentucky, Albert B Chandler Med Ctr, Ctr Sensor Technol, Dept Anat & Neurobiol, Lexington, KY 40536 USA
[2] Univ Kentucky, Albert B Chandler Med Ctr, Ctr Sensor Technol, Dept Neurol, Lexington, KY 40536 USA
[3] Univ Kentucky, Albert B Chandler Med Ctr, Morris K Udall Parkinsons Dis Res Ctr Excellence, Lexington, KY 40536 USA
[4] Univ Colorado, Hlth Sci Ctr, Dept Pharmacol, Denver, CO 80262 USA
关键词
L-glutamate; microelectrode; rat brain;
D O I
10.1016/S0165-0270(02)00172-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes improvements and further characterization of a ceramic-based multisite microclectrode for in vivo measurements of L-glutamate. Improvements include increased recording area, insulation deposition using photolithography for more uniform recording sites and forming the microelectrodes using a diamond saw providing smoother microelectrode edges. The new microelectrodes are triangular in shape, 1 cm in length and taper from 1 min to a 2-5 mum tip. Details on performing in vivo measurements are given, including microelectrode preparation, pitfalls of the recording method and approaches to enhance reproducibility of the technique. The detection limit for L-glutamate was lowered to similar to0.5 muM and a self-referencing recording technique was utilized to remove interferents as well as decrease noise. Applications of the microelectrodes to study L-glutamate uptake and release in rat prefrontal cortex, cortex, cerebellum and striatum are included. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 27 条
[1]   Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes [J].
Alvarez-Crespo, SL ;
Lobo-Castanon, MJ ;
Miranda-Ordieres, AJ ;
Tunon-Blanco, P .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (08) :739-747
[2]   Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes [J].
Burmeister, JJ ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1037-1042
[3]   Ceramic-based multisite microelectrodes for electrochemical recordings [J].
Burmeister, JJ ;
Moxon, K ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :187-192
[4]   CLEARANCE OF EXOGENOUS DOPAMINE IN RAT DORSAL STRIATUM AND NUCLEUS-ACCUMBENS - ROLE OF METABOLISM AND EFFECTS OF LOCALLY APPLIED UPTAKE INHIBITORS [J].
CASS, WA ;
ZAHNISER, NR ;
FLACH, KA ;
GERHARDT, GA .
JOURNAL OF NEUROCHEMISTRY, 1993, 61 (06) :2269-2278
[5]  
CHEN CY, 1991, ANAL CHIM ACTA, V243, P9
[6]   Pharmacological evidence for the selectivity of in vivo signals obtained with enzyme-based electrochemical sensors [J].
Cui, J ;
Kulagina, NV ;
Michael, AC .
JOURNAL OF NEUROSCIENCE METHODS, 2001, 104 (02) :183-189
[7]   Glutamate uptake [J].
Danbolt, NC .
PROGRESS IN NEUROBIOLOGY, 2001, 65 (01) :1-105
[8]   REGIONAL EFFECTS OF AGING ON DOPAMINERGIC FUNCTION IN THE FISCHER-344 RAT [J].
FRIEDEMANN, MN ;
GERHARDT, GA .
NEUROBIOLOGY OF AGING, 1992, 13 (02) :325-332
[9]   RELEASE OF MONOAMINES FROM STRIATUM OF RAT AND MOUSE EVOKED BY LOCAL APPLICATION OF POTASSIUM - EVALUATION OF A NEW INVIVO ELECTROCHEMICAL TECHNIQUE [J].
GERHARDT, GA ;
ROSE, GM ;
HOFFER, BJ .
JOURNAL OF NEUROCHEMISTRY, 1986, 46 (03) :842-850
[10]   Effects of recording media composition on the responses of Nafion-coated carbon fiber microelectrodes measured using high-speed chronoamperometry [J].
Gerhardt, GA ;
Hoffman, AF .
JOURNAL OF NEUROSCIENCE METHODS, 2001, 109 (01) :13-21