Biomechanical Comparison of Spinal Fusion Methods Using Interspinous Process Compressor and Pedicle Screw Fixation System Based on Finite Element Method

被引:16
作者
Choi, Jisoo [1 ]
Kim, Sohee [1 ,2 ,4 ]
Shin, Dong-Ah [3 ]
机构
[1] Gwangju Inst Sci & Technol, Dept Med Syst Engn, Gwangju, South Korea
[2] Gwangju Inst Sci & Technol, Sch Mechatron, Gwangju, South Korea
[3] Yonsei Univ, Coll Med, Dept Neurosurg, 50-1 Yonsei Ro, Seoul 03722, South Korea
[4] Daegu Gyeongbuk Inst Sci & Technol, Dept Robot Engn, Daegu, South Korea
基金
新加坡国家研究基金会;
关键词
Intervertebral disc degeneration; Pedicle screw; Interspinous device; Finite element analysis; Range of motion; LUMBAR SPINE; ADJACENT SEGMENTS; ARTHRODESIS; DISC; COMPLICATIONS; STENOSIS; UNIT;
D O I
10.3340/jkns.2016.59.2.91
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective : To investigate the biomechanical effects of a newly proposed Interspinous Process Compressor (IPC) and compare with pedicle screw fixation at surgical and adjacent levels of lumbar spine. Methods : A three dimensional finite element model of intact lumbar spine was constructed and two spinal fusion models using pedicle screw fixation system and a new type of interspinous devices, IPC, were developed. The biomechanical effects such as range of motion (ROM) and facet contact force were analyzed at surgical level (L3/4) and adjacent levels (L2/3, L4/5). In addition, the stress in adjacent intervertebral discs (D2, D4) was investigated. Results : The entire results show biomechanical parameters such as ROM, facet contact force, and stress in adjacent intervertebral discs were similar between PLIF and IPC models in all motions based on the assumption that the implants were perfectly fused with the spine. Conclusion : The newly proposed fusion device, IPC, had similar fusion effect at surgical level, and biomechanical effects at adjacent levels were also similar with those of pedicle screw fixation system. However, for clinical applications, real fusion effect between spinous process and hooks, duration of fusion, and influence on spinous process need to be investigated through clinical study.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 27 条
[1]   Spine stability after implantation of an interspinous device: an in vitro and finite element biomechanical study [J].
Anesetti, Federica ;
Galbusera, Fabio ;
Aziz, Hadi N. ;
Bellini, Chiara M. ;
Addis, Alessandro ;
Villa, Tomaso ;
Teli, Marco ;
Lovi, Alessio ;
Brayda-Bruno, Marco .
JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (05) :568-575
[2]   Critical analysis of trends in fusion for degenerative disc disease over the past 20 years - Influence of technique on fusion rate and clinical outcome [J].
Bono, CM ;
Lee, CK .
SPINE, 2004, 29 (04) :455-463
[3]  
Byun Dong-Hak, 2012, Korean J Spine, V9, P131, DOI 10.14245/kjs.2012.9.3.131
[4]   Perioperative complications of posterior lumbar decompression and arthrodesis in older adults [J].
Carreon, LY ;
Puno, RM ;
Dimar, JR ;
Glassman, SD ;
Johnson, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2089-2092
[5]   Biomechanical comparison between lumbar disc arthroplasty and fusion [J].
Chen, Shih-Hao ;
Zhong, Zheng-Cheng ;
Chen, Chen-Sheng ;
Chen, Wen-Jer ;
Hung, Chinghua .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (02) :244-253
[6]   Analysis of the effect of lumbar spine fusion on the superior adjacent intervertebral disk in the presence of disk degeneration, using the three-dimensional finite element method [J].
Chosa, E ;
Goto, K ;
Totoribe, K ;
Tajima, N .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (02) :134-139
[7]   Determination of the biomechanical effect of an interspinous process device on implanted and adjacent lumbar spinal segments using a hybrid testing protocol: a finite-element study [J].
Erbulut, Deniz U. ;
Zafarparandeh, Iman ;
Hassan, Chaudhry R. ;
Lazoglu, Ismail ;
Ozer, Ali F. .
JOURNAL OF NEUROSURGERY-SPINE, 2015, 23 (02) :200-208
[8]   1997 Volvo Award winner in clinical studies - Degenerative lumbar spondylolisthesis with spinal stenosis: A prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation [J].
Fischgrund, JS ;
Mackay, M ;
Herkowitz, HN ;
Brower, R ;
Montgomery, DM ;
Kurz, LT .
SPINE, 1997, 22 (24) :2807-2812
[9]   The use of pedicle-screw internal fixation for the operative treatment of spinal disorders [J].
Gaines, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1458-1476
[10]   INTERLAMINAR SHEAR STRESSES AND LAMINAE SEPARATION IN A DISC - FINITE-ELEMENT ANALYSIS OF THE L3-L4 MOTION SEGMENT SUBJECTED TO AXIAL COMPRESSIVE LOADS [J].
GOEL, VK ;
MONROE, BT ;
GILBERTSON, LG ;
BRINCKMANN, P ;
NAT, R .
SPINE, 1995, 20 (06) :689-698