Thermal Performance and Reliability Analysis of Single-Phase PV Inverters With Reactive Power Injection Outside Feed-In Operating Hours

被引:115
作者
Anurag, Anup [1 ]
Yang, Yongheng [2 ]
Blaabjerg, Frede [2 ]
机构
[1] Swiss Fed Inst Technol, Dept Elect Engn & Informat Technol, CH-8092 Zurich, Switzerland
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Photovoltaic (PV) inverters; Q at night; reactive ower injection; reliability; thermal performance; VOLTAGE RIDE-THROUGH; LIFETIME ESTIMATION; DESIGN; GENERATION; WIND; OPTIMIZATION; FILTER;
D O I
10.1109/JESTPE.2015.2428432
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Reactive power support by photovoltaic (PV) systems is of increasing interest, when compared with the conventional reactive power compensation devices. The PV inverters can exchange reactive power with the utility grid in a decentralized manner even outside feed-in operation, especially at night when there is no solar irradiance. However, reactive power injection causes additional power losses in the switching components leading to a temperature rise in the devices. Thus, this paper analyzes the impact of reactive power injection by PV inverters outside feed-in operation on the thermal performance of their power switching components. A thermal analysis based on the mission profile (i. e., solar irradiance and ambient temperature) has been incorporated, so as to determine the additional temperature rise in the components induced by the operation outside feed-in hours. An analytical lifetime model has been used. The damage produced on the transistors has been quantified using the Palmgren-Miner rule. A reliability analysis has been carried out on a PV inverter with and without the injection of reactive power into the utility grid at night. Economic impacts of injecting reactive power from PV inverters outside feed-in operating hours have been analyzed thereafter. This analysis can be helpful to make a better choice while choosing between conventional reactive power devices or PV inverters for injecting reactive power to the grid.
引用
收藏
页码:870 / 880
页数:11
相关论文
共 57 条
[1]  
ABB, 2011, APPL NOT THERM DES T
[2]   Single-Phase Single-Stage Transformer less Grid-Connected PV System [J].
Alajmi, Bader N. ;
Ahmed, Khaled H. ;
Adam, Grain Philip ;
Williams, Barry W. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2664-2676
[3]  
[Anonymous], 2002, Proc. PCIM PE4. 5, P59
[4]  
[Anonymous], 2013, 2013 15 EUR C POW EL
[5]  
ASTM International, 2011, ASTM E1049-85
[6]   Implemental Control Strategy for Grid Stabilization of Grid-Connected PV System Based on German Grid Code in Symmetrical Low-to-Medium Voltage Network [J].
Bae, Youngsang ;
Trung-Kien Vu ;
Kim, Rae-Young .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (03) :619-631
[7]   Reactive power allocation for loss minimisation in a stand alone variable speed constant frequency double output induction generator [J].
Bagarty, Durgesh Prasad ;
Kastha, Debaprasad .
IET POWER ELECTRONICS, 2013, 6 (05) :851-861
[8]  
Bayerer R., 2008, P IEEE 5 INT C INT P, P1
[9]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[10]  
Braun M., 2007, PROC 22 EUR PHOTOVOL, P2940