Quantitative structure-retention relationships applied to development of liquid chromatography gradient-elution method for the separation of sartans

被引:20
作者
Golubovic, Jelena [1 ]
Protic, Ana [1 ]
Otasevic, Biljana [1 ]
Zecevic, Mira [1 ]
机构
[1] Univ Belgrade, Fac Pharm, Dept Drug Anal, Vojvode Stepe 450,POB 146, Belgrade 11221, Serbia
关键词
II RECEPTOR ANTAGONISTS; SOLID-PHASE EXTRACTION; MASS-SPECTROMETRY; HUMAN PLASMA; HUMAN URINE; PREDICTION; HPLC; OPTIMIZATION; MODEL; DESCRIPTORS;
D O I
10.1016/j.talanta.2015.12.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
QSRR are mathematically derived relationships between the chromatographic parameters determined for a representative series of analytes in given separation systems and the molecular descriptors accounting for the structural differences among the investigated "analytes. Artificial neural network is a technique of data analysis, which sets out to emulate the human brain's way of working. The aim of the present work was to optimize separation of six angiotensin receptor antagonists, so-called sartans: losartan, valsartan, irbesartan, telmisartan, candesartan cilexetil and eprosartan in a gradient-elution HPLC method. For this purpose, ANN as a mathematical tool was used for establishing a QSRR model based on molecular descriptors of sartans and varied instrumental conditions. The optimized model can be further used for prediction of an external congener of sartans and analysis of the influence of the analyte structure, represented through molecular descriptors, on retention behaviour. Molecular descriptors included in modelling were electrostatic, geometrical and quantum-chemical descriptors: connolly solvent excluded volume non-1,4 van der Waals energy, octanol/water distribution coefficient, polarizability, number of proton-donor sites and number of proton-acceptor sites. Varied instrumental conditions were gradient time, buffer pH and buffer molarity. High prediction ability of the optimized network enabled complete separation of the analytes within the run time of 15.5 min under following conditions: gradient time of 12.5 min, buffer pH of 3.95 and buffer molarity of 25 mM. Applied methodology showed the potential to predict retention behaviour of an external analyte with the properties within the training space. Connolly solvent excluded volume, polarizability and number of proton-acceptor sites appeared to be most influential paramateres on retention behaviour of the sartans. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 36 条
  • [31] Towards a chromatographic similarity index to establish localised Quantitative Structure-Retention Relationships for retention prediction. III Combination of Tanimoto similarity index, logP, and retention factor ratio to identify optimal analyte training sets for ion chromatography
    Park, Soo Hyun
    Haddad, Paul R.
    Amos, Ruth I. J.
    Talebi, Mohammad
    Szucs, Roman
    Pohl, Christopher A.
    Dolan, John W.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1520 : 107 - 116
  • [32] Performance comparison of partial least squares-related variable selection methods for quantitative structure retention relationships modelling of retention times in reversed-phase liquid chromatography
    Talebi, Mohammad
    Schuster, Georg
    Shellie, Robert A.
    Szucs, Roman
    Haddad, Paul R.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1424 : 69 - 76
  • [33] Quantitative structure retention relationship (QSRR) approach for assessment of chromatographic behavior of antiviral drugs in the development of liquid chromatographic method
    Paritala, Jagadeesh
    Peraman, Ramalingam
    Kondreddy, Vinod Kumar
    Subrahmanyam, C. V. S.
    Ravichandiran, V
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2021, 44 (13-14) : 637 - 648
  • [34] Performance comparison of nonlinear and linear regression algorithms coupled with different attribute selection methods for quantitative structure - retention relationships modelling in micellar liquid chromatography
    Krmar, Jovana
    Vukicevic, Milan
    Kovacevic, Ana
    Protic, Ana
    Zecevic, Mira
    Otasevic, Biljana
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1623
  • [35] Multimode Gradient Elution in Reversed-Phase Liquid Chromatography: Application to Retention Prediction and Separation Optimization. of a Set of Amino Acids in Gradient Runs Involving Simultaneous Variations of Mobile-Phase Composition, Flow Rate, and Temperature
    Pappa-Louisi, A.
    Nikitas, P.
    Papachristos, K.
    Balkatzopoulou, P.
    ANALYTICAL CHEMISTRY, 2009, 81 (03) : 1217 - 1223
  • [36] Support Vector Models-Based Quantitative Structure-Retention Relationship (QSRR) in the Development and Validation of RP-HPLC Method for Multi-component Analysis of Anti-diabetic Drugs
    Rajput, Krishnapal
    Dhiman, Shubham
    Veni, N. Krishna
    Ravichandiran, V.
    Peraman, Ramalingam
    CHROMATOGRAPHIA, 2024, 87 (01) : 3 - 16