Quantitative structure-retention relationships applied to development of liquid chromatography gradient-elution method for the separation of sartans

被引:20
作者
Golubovic, Jelena [1 ]
Protic, Ana [1 ]
Otasevic, Biljana [1 ]
Zecevic, Mira [1 ]
机构
[1] Univ Belgrade, Fac Pharm, Dept Drug Anal, Vojvode Stepe 450,POB 146, Belgrade 11221, Serbia
关键词
II RECEPTOR ANTAGONISTS; SOLID-PHASE EXTRACTION; MASS-SPECTROMETRY; HUMAN PLASMA; HUMAN URINE; PREDICTION; HPLC; OPTIMIZATION; MODEL; DESCRIPTORS;
D O I
10.1016/j.talanta.2015.12.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
QSRR are mathematically derived relationships between the chromatographic parameters determined for a representative series of analytes in given separation systems and the molecular descriptors accounting for the structural differences among the investigated "analytes. Artificial neural network is a technique of data analysis, which sets out to emulate the human brain's way of working. The aim of the present work was to optimize separation of six angiotensin receptor antagonists, so-called sartans: losartan, valsartan, irbesartan, telmisartan, candesartan cilexetil and eprosartan in a gradient-elution HPLC method. For this purpose, ANN as a mathematical tool was used for establishing a QSRR model based on molecular descriptors of sartans and varied instrumental conditions. The optimized model can be further used for prediction of an external congener of sartans and analysis of the influence of the analyte structure, represented through molecular descriptors, on retention behaviour. Molecular descriptors included in modelling were electrostatic, geometrical and quantum-chemical descriptors: connolly solvent excluded volume non-1,4 van der Waals energy, octanol/water distribution coefficient, polarizability, number of proton-donor sites and number of proton-acceptor sites. Varied instrumental conditions were gradient time, buffer pH and buffer molarity. High prediction ability of the optimized network enabled complete separation of the analytes within the run time of 15.5 min under following conditions: gradient time of 12.5 min, buffer pH of 3.95 and buffer molarity of 25 mM. Applied methodology showed the potential to predict retention behaviour of an external analyte with the properties within the training space. Connolly solvent excluded volume, polarizability and number of proton-acceptor sites appeared to be most influential paramateres on retention behaviour of the sartans. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 36 条
  • [1] Quantitative structure-retention relationships applied to liquid chromatography gradient elution method for the determination of carbonyl-2,4-dinitrophenylhydrazone compounds
    Cirera-Domenech, Elisenda
    Estrada-Tejedor, Roger
    Broto-Puig, Francesc
    Teixido, Jordi
    Gassiot-Matas, Miquel
    Comellas, Lluis
    Lluis Lliberia, Josep
    Mendez, Alberto
    Paz-Estivill, Susanna
    Rosa Delgado-Ortiz, Maria
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1276 : 65 - 77
  • [2] Accurate modelling of the retention behaviour of peptides in gradient-elution hydrophilic interaction liquid chromatography
    Roca, Liana S.
    Schoemaker, Suzan E.
    Pirok, Bob W. J.
    Gargano, Andrea F. G.
    Schoenmakers, Peter J.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1614
  • [3] Investigation of supercritical fluid chromatography retention behaviors using quantitative structure-retention relationships
    Le Si-Hung
    Izumi, Yoshihiro
    Nakao, Motonao
    Takahashi, Masatomo
    Bamba, Takeshi
    ANALYTICA CHIMICA ACTA, 2022, 1197
  • [4] Gradient Retention Time Modeling in Ion Chromatography through Ensemble Machine Learning-Powered Quantitative Structure-Retention Relationships
    Lim, Zhen Jia
    Zuvela, Petar
    Ukic, Sime
    Stankov, Mirjana Novak
    Bolanca, Tomislav
    Lovric, Mario
    Wong, Ming Wah
    Buszewski, Boguslaw
    ACS OMEGA, 2025, 10 (06): : 5993 - 6002
  • [5] Method Optimisation in Hydrophilic-Interaction Liquid Chromatography by Design of Experiments Combined with Quantitative Structure-Retention Relationships
    Taraji, Maryam
    Haddad, Paul R.
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2021, 74 (11) : 778 - 786
  • [6] Rapid Method Development in Hydrophilic Interaction Liquid Chromatography for Pharmaceutical Analysis Using a Combination of Quantitative Structure-Retention Relationships and Design of Experiments
    Taraji, Maryam
    Haddad, Paul R.
    Amos, Ruth I. J.
    Talebi, Mohammad
    Szucs, Roman
    Dolan, John W.
    Pohl, Chris A.
    ANALYTICAL CHEMISTRY, 2017, 89 (03) : 1870 - 1878
  • [7] Strategy for reduced calibration sets to develop quantitative structure-retention relationships in high-performance liquid chromatography
    Andries, Jan P. M.
    Claessens, Henk A.
    Heyden, Yvan Vander
    Buydens, Lutgarde M. C.
    ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) : 180 - 188
  • [8] Localised quantitative structure-retention relationship modelling for rapid method development in reversed-phase high performance liquid chromatography
    Park, Soo Hyun
    De Pra, Mauro
    Haddad, Paul R.
    Grosse, Sylvia
    Pohl, Christopher A.
    Steiner, Frank
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1609
  • [9] Prediction of the retention of s-triazines in reversed-phase high-performance liquid chromatography under linear gradient-elution conditions
    D'Archivio, Angelo Antonio
    Maggi, Maria Anna
    Ruggieri, Fabrizio
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (15) : 1930 - 1936
  • [10] Perspectives and recent advances in quantitative structure-retention relationships for high performance liquid chromatography. How far are we?
    Sagandykova, Gulyaim
    Buszewski, Boguslaw
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 141