Morphological study of the proximal femur: a new method of geometrical assessment using 3-dimensional reverse engineering

被引:111
作者
Mahaisavariya, B [1 ]
Sitthiseripratip, K
Tongdee, T
Bohez, ELJ
Vander Sloten, J
Oris, P
机构
[1] Mahidol Univ, Fac Med, Dept Orthopaed Surg, Siriraj Hosp, Bangkok 10700, Thailand
[2] Asian Inst Technol, Pathum Thani, Thailand
[3] Mahidol Univ, Siriraj Hosp, Dept Radiol, Fac Med, Bangkok 10700, Thailand
[4] Katholieke Univ Leuven, Div Biomech & Engn Design, Louvain, Belgium
关键词
morphological study; proximal femur; reverse engineering technique;
D O I
10.1016/S1350-4533(02)00113-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study presents a new method of using computerized tomography images combined with the reverse engineering technique to obtain and analyse the three-dimensional inner and outer geometry of the proximal cadaveric femur. Three-dimensional models were reconstructed from the computerized tomography images and approximated with 2D and 3D fitting algorithms based on reverse engineering methods. The following parameters were calculated for each femur: femoral head diameter, femoral neck axis, femoral shaft axis, anteversion angle and neck-shaft angle, These data represent the geometry of the studied proximal femur, and can be used for the design of proper size and shape of femoral prostheses and trochanteric nail systems. (C) 2002 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:617 / 622
页数:6
相关论文
共 5 条
  • [1] Geometric mismatch of the gamma nail to the Chinese femur
    Leung, KS
    Procter, P
    Robioneck, B
    Behrens, K
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (323) : 42 - 48
  • [2] CRACKING OF THE FEMORAL-SHAFT BY THE GAMMA NAIL
    MAHAISAVARIYA, B
    LAUPATTARAKASEM, W
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1992, 23 (07): : 493 - 494
  • [3] NOBLE PC, 1988, CLIN ORTHOP RELAT R, P148
  • [4] SITTHISERIPRATI.K, 2001, P 18 C INT SOC BIOM
  • [5] Techanivete P, 1995, J THAI ORTHOP ASS, V20, P2