Protection of occupants from exhaled infectious agents and floor material emissions in rooms with personalized and underfloor ventilation

被引:84
作者
Cermak, Radim [1 ]
Melikov, Arsen K.
机构
[1] Ingersoll Rand Climat Control Technol, Ctr Res & Dev, Prague, Czech Republic
[2] Tech Univ Denmark, Dept Mech Engn, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
来源
HVAC&R RESEARCH | 2007年 / 13卷 / 01期
关键词
D O I
10.1080/10789669.2007.10390942
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of two personalized. ventilation systems supplying air at the breathing zone was tested in conjunction with underfloor ventilation generating two different airflow patterns in a full-scale test room. Two breathing thermal manikins were used to simulate occupants. The distribution of pollutants associated with exhaled air and floor material emissions was evaluated at various combinations of personalized and underfloor airflow rates. Compared to underfloor ventilation alone, personalized and underfloor ventilation provided excellent protection Of seated occupants from any pollution, while the concentration of exhaled air pollution increased in the room. The two types of personalized ventilation performed differently. Subsequent analyses of airborne infection transmission risk indicated that personalized ventilation could become a supplement to traditional methods of infection control.
引用
收藏
页码:23 / 38
页数:16
相关论文
共 35 条
[21]   Plastic wall materials in the home and respiratory health in young children [J].
Jaakkola, JJK ;
Verkasalo, PK ;
Jaakkola, N .
AMERICAN JOURNAL OF PUBLIC HEALTH, 2000, 90 (05) :797-799
[22]   Human response to personalized ventilation and mixing ventilation [J].
Kaczmarczyk, J ;
Melikov, A ;
Fanger, PO .
INDOOR AIR, 2004, 14 :17-29
[23]   Multi-zone modeling of probable SARS virus transmission by airflow between flats in Block E, Amoy Gardens [J].
Li, Y ;
Duan, S ;
Yu, ITS ;
Wong, TW .
INDOOR AIR, 2005, 15 (02) :96-111
[24]   Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong [J].
Li, Y ;
Huang, X ;
Yu, ITS ;
Wong, TW ;
Qian, H .
INDOOR AIR, 2005, 15 (02) :83-95
[25]  
LI Y, 2006, IN PRESS INDOOR AIR
[26]   Personalized ventilation [J].
Melikov, AK .
INDOOR AIR, 2004, 14 :157-167
[27]   Personalized ventilation: evaluation of different air terminal devices [J].
Melikov, AK ;
Cermak, R ;
Majer, M .
ENERGY AND BUILDINGS, 2002, 34 (08) :829-836
[28]  
MELIKOV AK, 2004, P ROOMV 200J SEPT 5
[29]  
MELIKOV AK, P HLTH BUILD 2003 SI
[30]  
MELIKOV AK, 2000, P ROOMV 2000, V1, P101