Therapeutic analysis of high-dose-rate 192Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

被引:7
作者
Zhang, Hualin [1 ]
Donnelly, Eric D. [1 ]
Strauss, Jonathan B. [1 ]
Qi, Yujin [2 ]
机构
[1] Northwestern Univ, NW Mem Hosp, Robert H Lurie Comprehens Canc Ctr, Dept Radiat Oncol,Feinberg Sch Med, Chicago, IL 60611 USA
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
关键词
high-dose-rate Ir-192 source; brachytherapy; Monte Carlo; endometrial cancer; linear quadratic model; RADIATION-THERAPY; AAPM; FRACTIONATION; RADIOTHERAPY; GUIDELINES; DOSIMETRY; CARCINOMA; OUTCOMES;
D O I
10.1118/1.4939064
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gyx4 fractions) or at the vaginal mucosal surface (8.8 Gyx4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gyx4 and 7.8 Gyx4, the TRs were in the range from (5.0) 4 to (13.4) 4 for the radiosensitive normal tissue depending on the cylinder size, treatment lengths, prescription depth, and dose as well. However, for a uniform cancer cell distribution, the EUDs were between 6.3 Gyx4 and 7.1 Gyx4, and the TRs were found to be between (1.4) 4 and (1.7) 4. For the uniformly interspersed cancer and radio-resistant normal cells, the TRs were less than 1. The two VCBT prescription regimens were found to be equivalent in terms of EUDs and TRs. Conclusions: HDR VCBT strongly favors cylindrical target volume with the cancer cell distribution following its dosimetric trend. Assuming a half-Gaussian distribution of cancer cells, the HDR VCBT provides a considerable radiobiological advantage over the external beam radiotherapy (EBRT) in terms of sparing more normal tissues while maintaining the same level of cancer cell killing. But for the uniform cancer cell distribution and radio-resistant normal tissue, the radiobiology outcome of the HDR VCBT does not show an advantage over the EBRT. This study strongly suggests that radiation therapy design should consider the cancer cell distribution inside the target volume in addition to the shape of target. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:483 / 494
页数:12
相关论文
共 50 条
  • [1] A comparison of the biological effective dose of 50-kV electronic brachytherapy with 192Ir high-dose-rate brachytherapy for vaginal cuff irradiation
    Rava, Paul
    Dvorak, Tomas
    Markelewicz, Robert J., Jr.
    Hiatt, Jessica R.
    Sternick, Edward S.
    MacAusland, Stephanie G.
    Huber, Kathryn
    Wazer, David E.
    Hepel, Jaroslaw T.
    BRACHYTHERAPY, 2012, 11 (05) : 402 - 407
  • [2] Salvage high-dose-rate brachytherapy for isolated vaginal recurrence of endometrial cancer
    Baek, Sungjae
    Isohashi, Fumiaki
    Yamaguchi, Hiroko
    Mabuchi, Seiji
    Yoshida, Ken
    Kotsuma, Tadayuki
    Yamazaki, Hideya
    Tanaka, Eiichi
    Sumida, Iori
    Tamari, Keisuke
    Otani, Keisuke
    Seo, Yuji
    Suzuki, Osamu
    Yoshioka, Yasuo
    Kimura, Tadashi
    Ogawa, Kazuhiko
    BRACHYTHERAPY, 2016, 15 (06) : 812 - 816
  • [3] Lack of the Dose-Rate Effect of 192Ir Source Activity on Pelvic Control and Late Complications After High-Dose-Rate Brachytherapy for Cervical Cancer
    Chen, Shang-Wen
    Liang, Ji-An
    Shiau, An-Chang
    Yu, Chun-Yen
    Hung, Yao-Ching
    Yeh, Lian-Shung
    Chang, Wei-Chun
    Lin, Wu-Chou
    Yang, Shih-Neng
    Lin, Fang-Jen
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (02) : 173 - 179
  • [4] Dosimetric impact of cylinder size in high-dose rate vaginal cuff brachytherapy (VCBT) for primary endometrial cancer
    Zhang, Hualin
    Gopalakrishnan, Mahesh
    Lee, Plato
    Kang, Zhuang
    Sathiaseelan, Vythialingam
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 262 - 272
  • [5] The dosimetric impact of heterogeneity corrections in high-dose-rate 192Ir brachytherapy for cervical cancer: Investigation of both conventional Point-A and volume-optimized plans
    Hyer, Daniel E.
    Sheybani, Arshin
    Jacobson, Geraldine M.
    Kim, Yusung
    BRACHYTHERAPY, 2012, 11 (06) : 515 - 520
  • [6] High-dose-rate interstitial brachytherapy for vaginal endometrial cancer recurrence after prior surgery and radiotherapy
    Chapman, Christopher H.
    Cunha, Adam J.
    Littell, Ramey D.
    Chen, Lee-May
    Hsu, I-Chow
    BRACHYTHERAPY, 2021, 20 (03) : 536 - 542
  • [7] MR- versus CT-based high-dose-rate interstitial brachytherapy for vaginal recurrence of endometrial cancer
    Kamran, Sophia C.
    Manuel, Matthias M.
    Catalano, Paul
    Cho, Linda
    Damato, Antonio L.
    Lee, Larissa J.
    Schmidt, Ehud J.
    Viswanathan, Akila N.
    BRACHYTHERAPY, 2017, 16 (06) : 1159 - 1168
  • [8] Assessment of air pockets in high-dose-rate vaginal cuff brachytherapy using cylindrical applicators
    Hassouna, Ashraf
    Bahadur, Yasir Abdulaziz
    Constantinescu, Camelia
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (03) : 271 - 275
  • [9] Comparative Analysis of 60Co and 192Ir Sources in High Dose Rate Brachytherapy for Cervical Cancer
    Wen, Aiping
    Wang, Xianliang
    Wang, Bingjie
    Yan, Chuanjun
    Luo, Jingyue
    Wang, Pei
    Li, Jie
    CANCERS, 2022, 14 (19)
  • [10] Salvage treatment with high-dose-rate brachytherapy for isolated vaginal endometrial cancer recurrence
    Petignat, Patrick
    Jolicoeur, Marjory
    Alobaid, Abdulaziz
    Drouin, Pierre
    Gauthier, Philippe
    Provencher, Diane
    Donath, David
    Nguyen, Thu Van
    GYNECOLOGIC ONCOLOGY, 2006, 101 (03) : 445 - 449