A spiral implant as nucleus prosthesis in the lumbar spine

被引:31
作者
Korge, A
Nydegger, T
Polard, JL
Mayer, HM
Husson, JL
机构
[1] Orthoped Clin Munich Harlaching, Spine Ctr, D-81547 Munich, Germany
[2] Sulzer Orthoped, Winterthur, Switzerland
[3] CHU Hotel Dieu, Serv Orthoped Traumatol A, Rennes, France
关键词
nucleus prosthesis; artificial disc; non-fusion treatment; spine arthroplasty; discogenic pain;
D O I
10.1007/s00586-002-0444-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Microdiscectomy represents the gold standard in disc surgery on the lumbar spine. The remaining defect in the intervertebral disc space can be filled with a newly developed nucleus prosthesis presented in this paper. This prosthesis consists of polycarbonate urethane (Sulene(TM) PCU), and takes the form of a memory coiling spiral. It can be easily implanted using the standard microdiscectomy approach with no further tissue damage. Biomechanical tests have shown that anatomical distances can be restored by the spiral for both the facet joints and the endplates. Endplate deformations are not statistically different when compared to intact conditions. Inclusion and exclusion criteria of an in vivo pilot study are presented. The paper describes the insertion setup for the spiral and the technique of implantation. Five patients have been supplied with the implant to date. The first results on postoperative magnetic resonance images are presented.
引用
收藏
页码:S149 / S153
页数:5
相关论文
共 13 条
[1]   ABNORMAL MAGNETIC-RESONANCE SCANS OF THE LUMBAR SPINE IN ASYMPTOMATIC SUBJECTS - A PROSPECTIVE INVESTIGATION [J].
BODEN, SD ;
DAVIS, DO ;
DINA, TS ;
PATRONAS, NJ ;
WIESEL, SW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :403-408
[2]   CHANGE OF DISK HEIGHT, RADIAL DISK BULGE, AND INTRADISCAL PRESSURE FROM DISCECTOMY - AN INVITRO INVESTIGATION ON HUMAN LUMBAR DISKS [J].
BRINCKMANN, P ;
GROOTENBOER, H .
SPINE, 1991, 16 (06) :641-646
[3]   DISK SPACE NARROWING AND THE LUMBAR FACET JOINTS [J].
DUNLOP, RB ;
ADAMS, MA ;
HUTTON, WC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (05) :706-710
[4]  
EDELAND HG, 1981, BIOMATER ARTIF CELL, V9, P65, DOI 10.3109/10731198109117602
[5]  
EDELAND HG, 1989, J BIOMED MAT RESOURC, V23, P189
[6]  
FREI HP, 1999, EUR SPINE J, V8, pS36
[7]  
FRONING EC, 1975, Patent No. 3875595
[8]   FACET JOINT CHANGES AFTER CHEMONUCLEOLYSIS-INDUCED DISK SPACE NARROWING [J].
GOTFRIED, Y ;
BRADFORD, DS ;
OEGEMA, TR .
SPINE, 1986, 11 (09) :944-950
[9]  
HUSSON JL, 1996, RESTABILISATION INTE, P311
[10]  
Husson JL, 1997, RACHIS, V9, P145