De novo peptide sequencing by tandem MS using complementary CID and electron transfer dissociation

被引:40
作者
Bertsch, Andreas [1 ]
Leinenbach, Andreas [3 ]
Pervukhin, Anton [4 ]
Lubeck, Markus [5 ]
Hartmer, Ralf [5 ]
Baessmann, Carsten [5 ]
Elnakady, Yasser Abbas [2 ]
Mueller, Rolf [2 ]
Boecker, Sebastian [4 ]
Huber, Christian G. [3 ]
Kohlbacher, Oliver
机构
[1] Univ Tubingen, Wilhelm Schickard Inst, Ctr Bioinformat Tubingen, D-72076 Tubingen, Germany
[2] Univ Saarland, Dept Pharmaceut Biotechnol, D-6600 Saarbrucken, Germany
[3] Salzburg Univ, Dept Mol Biol, Div Chem & Bioanalyt, A-5020 Salzburg, Austria
[4] Univ Jena, Lehrstuhl Bioinformat, Jena, Germany
[5] Bruker Daltonik GmbH, Bremen, Germany
关键词
CID; De novo; ETD; OpenMS; Sorangium cellulosum; COLLISION-INDUCED DISSOCIATION; MASS-SPECTROMETRY; PROTEIN IDENTIFICATION; ION/ION REACTIONS; ION-TRAP; SPECTRA; SEPARATION; ALGORITHM; SINGLE; AID;
D O I
10.1002/elps.200900332
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
De novo sequencing of peptides using tandem MS is difficult due to missing fragment ions in the spectra commonly obtained after CID of peptide precursor ions. Complementing CID spectra with spectra obtained in an ion-trap mass spectrometer upon electron transfer dissociation (ETD) significantly increases the sequence coverage with diagnostic ions. in the de novo sequencing algorithm CompNovo presented here, a divide-and-conquer approach was combined with an efficient mass decomposition algorithm to exploit the complementary information contained in CID and ETD spectra. After optimizing the parameters for the algorithm on a well-defined training data set obtained for peptides from nine known proteins, the CompNovo algorithm was applied to the de novo sequencing of peptides derived from a whole protein extract of Sorangium cellulosum bacteria. To 2406 pairs of CID and ETD spectra contained in this data set, 675 fully correct sequences were assigned, which represent a success rate of 28.1%. It is shown that the CompNovo algorithm yields significantly improved sequencing accuracy as compared with published approaches using only CID spectra or combined CID and ETD spectra
引用
收藏
页码:3736 / 3747
页数:12
相关论文
共 55 条
  • [1] Bafna V, 2001, Bioinformatics, V17 Suppl 1, pS13
  • [2] FAST ALGORITHM FOR PEPTIDE SEQUENCING BY MASS-SPECTROSCOPY
    BARTELS, C
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (06): : 363 - 368
  • [3] De novo analysis of peptide tandem mass spectra by spectral graph partitioning
    Bern, M
    Goldberg, D
    [J]. JOURNAL OF COMPUTATIONAL BIOLOGY, 2006, 13 (02) : 364 - 378
  • [4] CONTRIBUTIONS OF MASS-SPECTROMETRY TO PEPTIDE AND PROTEIN-STRUCTURE
    BIEMANN, K
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12): : 99 - 111
  • [5] DECOMP -: from interpreting mass spectrometry peaks to solving the money changing problem
    Boecker, Sebastian
    Liptak, Zsuzsanna
    Martin, Marcel
    Pervukhin, Anton
    Sudek, Henner
    [J]. BIOINFORMATICS, 2008, 24 (04) : 591 - 593
  • [6] A fast and simple algorithm for the money changing problem
    Boecker, Sebastian
    Liptak, Zsuzsanna
    [J]. ALGORITHMICA, 2007, 48 (04) : 413 - 432
  • [7] SIRIUS: decomposing isotope patterns for metabolite identification
    Boecker, Sebastian
    Letzel, Matthias C.
    Liptak, Zsuzsanna
    Pervukhin, Anton
    [J]. BIOINFORMATICS, 2009, 25 (02) : 218 - 224
  • [8] CHEN KC, 2003, P 5 INT C ASIC, V1, P12
  • [9] A dynamic programming approach to de novo peptide sequencing via tandem mass spectrometry
    Chen, T
    Kao, MY
    Tepel, M
    Rush, J
    Church, GM
    [J]. JOURNAL OF COMPUTATIONAL BIOLOGY, 2001, 8 (03) : 325 - 337
  • [10] TANDEM: matching proteins with tandem mass spectra
    Craig, R
    Beavis, RC
    [J]. BIOINFORMATICS, 2004, 20 (09) : 1466 - 1467