Influence of controlled immediate loading and implant design on peri-implant bone formation

被引:54
|
作者
Vandamme, Katleen
Naert, Ignace
Geris, Liesbet
Vander Sloten, Jozef
Puers, Robert
Duyck, Joke
机构
[1] Katholieke Univ Leuven, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Prosthet Dent,BIOMAT Res Grp, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Div Biomech & Engn Design, Louvain, Belgium
[3] Katholieke Univ Leuven, Dept Elect Engn, ESAT, MICAS, Louvain, Belgium
关键词
animal; bone chamber; immediate loading; implant macro-design; peri-implant healing;
D O I
10.1111/j.1600-051X.2006.01014.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. Material and Methods: A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. Results: A significantly higher bone area fraction was observed for SL compared with SU (p < 0.0001). The mineralized bone fraction was the highest for SL and significantly different from SU (p < 0.0001). The chance that osteoid- and bone-to-implant contact occurred was the highest for SL and significantly different from SU (p < 0.0001), but not from CL. When bone-to-implant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Conclusions: Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.
引用
收藏
页码:172 / 181
页数:10
相关论文
共 50 条
  • [41] Peri-implant Tissue Response Following Connective Tissue and Bone Grafting in Conjunction with Immediate Single-Tooth Replacement in the Esthetic Zone: A Case Series
    Tsuda, Hirotaka
    Rungcharassaeng, Kitichai
    Kan, Joseph Y. K.
    Roe, Phillip
    Lozada, Jaime L.
    Zimmerman, Grenith
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (02) : 427 - 436
  • [42] Immediate Loading of Unsplinted Implant Retained Mandibular Overdenture: A Randomized Controlled Clinical Study
    Kutkut, Ahmad
    Rezk, Mohamed
    Zephyr, Dominique
    Dawson, Dolphus
    Frazer, Robert
    Al-Sabbagh, Mohanad
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (05) : 378 - 389
  • [43] Clinical evaluation of the implant survival rate in patients subjected to immediate implant loading protocols
    Silva, Antonio Sergio
    Martins, Diva
    de Sa, Juliana
    Mendes, Jose Manuel
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (01) : 61 - 68
  • [44] Immediate implant placement and immediate loading in the esthetic area A literature review
    Kallab, Sandra
    Obreja, Karina
    Schwarz, Frank
    Parvini, Puria
    IMPLANTOLOGIE, 2024, 32 (04): : 433 - 446
  • [45] Immediate placement, immediate loading of single implant in fresh extraction socket
    Gupta, Gaurav
    Gupta, D. K.
    Gupta, Neelja
    Gupta, Priyanka
    Rana, Kuldeep Singh
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (02) : 389 - 393
  • [46] Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level
    Scepanovic, Miodrag
    Todorovic, Aleksandar
    Markovic, Aleksa
    Patrnogic, Vesna
    Milicic, Biljana
    Moufti, Adel M.
    Misic, Tijana
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2015, 199 : 85 - 91
  • [47] Histologic and histomorphometric evaluation of peri-implant bone of immediate or delayed occlusal-loaded non-splinted implants in the posterior mandible - an experimental study in monkeys
    Stokholm, Rie
    Isidor, Flemming
    Nyengaard, Jens R.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (11) : 1311 - 1318
  • [48] Do repeated changes of abutments have any influence on the stability of peri-implant tissues? One-year post-loading results from a multicentre randomised controlled trial
    Esposito, Marco
    Bressan, Eriberto
    Grusovin, Maria Gabriella
    D'Avenia, Ferdinando
    Neumann, Konrad
    Sbricoli, Luca
    Luongo, Giuseppe
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (01) : 57 - 72
  • [49] Immediate loading of an implant following implant site development using forced eruption: A case report
    Park, YS
    Yi, KY
    Moon, SC
    Jung, YC
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (04) : 621 - 626
  • [50] Immediate Loading as a Vehicle for Interdisciplinary Training in Implant Placement and Restoration
    Kim, Eun-Suk
    Park, Eun-Jin
    Schrott, Alexander
    Schnitman, Paul A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 759 - 762