Influence of controlled immediate loading and implant design on peri-implant bone formation

被引:54
|
作者
Vandamme, Katleen
Naert, Ignace
Geris, Liesbet
Vander Sloten, Jozef
Puers, Robert
Duyck, Joke
机构
[1] Katholieke Univ Leuven, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Prosthet Dent,BIOMAT Res Grp, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Div Biomech & Engn Design, Louvain, Belgium
[3] Katholieke Univ Leuven, Dept Elect Engn, ESAT, MICAS, Louvain, Belgium
关键词
animal; bone chamber; immediate loading; implant macro-design; peri-implant healing;
D O I
10.1111/j.1600-051X.2006.01014.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. Material and Methods: A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. Results: A significantly higher bone area fraction was observed for SL compared with SU (p < 0.0001). The mineralized bone fraction was the highest for SL and significantly different from SU (p < 0.0001). The chance that osteoid- and bone-to-implant contact occurred was the highest for SL and significantly different from SU (p < 0.0001), but not from CL. When bone-to-implant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Conclusions: Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.
引用
收藏
页码:172 / 181
页数:10
相关论文
共 50 条
  • [31] Clinical aspects of immediate implant placement and immediate loading
    Schnutenhaus, Sigmar
    Buschbeck, Eric
    Luthardt, Ralph G.
    Edelmann, Cornelia
    IMPLANTOLOGIE, 2020, 28 (01): : 25 - 36
  • [32] Study on Angle of Immediate Loading of Immediate Implant Placement
    Luo, Sheng-Lei
    Yuan, Kui-feng
    Lai, Qing-guo
    Yang, Zhong-jun
    Tang, Xiao-peng
    Xu, Xin
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (03) : 700 - 705
  • [33] The influence of repeated abutment changes on peri-implant tissue stability: 3-year post-loading results from a multicentre randomised controlled trial
    Bressan, Eriberto
    Grusovin, Maria Gabriella
    D'Avenia, Ferdinando
    Neumann, Konrad
    Sbricoli, Luca
    Luongo, Giuseppe
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (04) : 373 - 390
  • [34] The behavior of new hydrophilic composite bone cements for immediate loading of dental implant
    Yihui Ma
    Ruoli Wang
    Xiangrong Cheng
    Zhilan Liu
    Yufeng Zhang
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2013, 28 : 627 - 633
  • [35] The behavior of new hydrophilic composite bone cements for immediate loading of dental implant
    Ma Yihui
    Wang Ruoli
    Cheng Xiangrong
    Liu Zhilan
    Zhang Yufeng
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2013, 28 (03): : 627 - 633
  • [36] PUTATIVE EARLY RISK FACTORS AT BONE-IMPLANT INTERFACE IN IMMEDIATE LOADING
    Iliescu, Alexandru-Andrei
    Iliescu, Radita
    Rusu, Darian
    Didilescu, Andreea Cristiana
    Tanase, Gabriela
    Iliescu, Andrei
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2009, 1 (01): : 25 - 33
  • [37] The Behavior of New Hydrophilic Composite Bone Cements for Immediate Loading of Dental Implant
    马毅慧
    WANG Ruoli
    程祥荣
    LIU Zhilan
    ZHANG Yufeng
    Journal of Wuhan University of Technology(Materials Science), 2013, (03) : 627 - 633
  • [38] Indications for immediate loading of implants and implant success
    Nkenke, Emeka
    Fenner, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 : 19 - 34
  • [39] Prosthetic Requirements for Immediate Implant Loading: A Review
    El Ghoul, Wiam
    Chidiac, Jose Johann
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (02): : 141 - 154
  • [40] Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial
    Torroella-Saura, Gerard
    Mareque-Bueno, Javier
    Cabratosa-Termes, Josep
    Hernandez-Alfaro, Federico
    Ferres-Padro, Eduard
    Luis Calvo-Guirado, Jose
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (03) : 240 - 244