Influence of controlled immediate loading and implant design on peri-implant bone formation

被引:54
|
作者
Vandamme, Katleen
Naert, Ignace
Geris, Liesbet
Vander Sloten, Jozef
Puers, Robert
Duyck, Joke
机构
[1] Katholieke Univ Leuven, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Prosthet Dent,BIOMAT Res Grp, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Div Biomech & Engn Design, Louvain, Belgium
[3] Katholieke Univ Leuven, Dept Elect Engn, ESAT, MICAS, Louvain, Belgium
关键词
animal; bone chamber; immediate loading; implant macro-design; peri-implant healing;
D O I
10.1111/j.1600-051X.2006.01014.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. Material and Methods: A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. Results: A significantly higher bone area fraction was observed for SL compared with SU (p < 0.0001). The mineralized bone fraction was the highest for SL and significantly different from SU (p < 0.0001). The chance that osteoid- and bone-to-implant contact occurred was the highest for SL and significantly different from SU (p < 0.0001), but not from CL. When bone-to-implant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Conclusions: Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.
引用
收藏
页码:172 / 181
页数:10
相关论文
共 50 条
  • [21] Peri-implant bone response following immediate implants placed in the esthetic zone and with immediate provisionalization—a case series study
    Martin C.
    Thomé G.
    Melo A.C.M.
    Fontão F.N.G.K.
    Oral and Maxillofacial Surgery, 2015, 19 (2) : 157 - 163
  • [22] Peri-implant tissue reactions to immediate nonocclusal loaded implants with different collar design: an experimental study in dogs
    Negri, Bruno
    Calvo Guirado, Jose L.
    Sanchez de Val, Jose E. Mate
    Delgado Ruiz, Rafael A.
    Ramirez Fernandez, Maria P.
    Barona Dorado, Cristina
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : E54 - E63
  • [23] A retrospective analysis of peri-implant tissue responses at immediate load/provisionalized microthreaded implants
    De Kok, Ingeborg J.
    Chang, Sandra S.
    Moriarty, John D.
    Cooper, Lyndon F.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (03) : 405 - 412
  • [24] Effects of different loading protocols on the secondary stability and peri-implant bone density of the single implants in the posterior maxilla
    Akoglan, Mucahide
    Tatli, Ufuk
    Kurtoglu, Cem
    Salimov, Fariz
    Kurkcu, Mehmet
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (04) : 624 - 631
  • [25] Simulation of pen-implant bone healing due to immediate loading in dental implant treatments
    Chou, Hsuan-Yu
    Mueftue, Sinan
    JOURNAL OF BIOMECHANICS, 2013, 46 (05) : 871 - 878
  • [26] Effect of Platelet Rich Fibrin (PRF) on Peri-implant Soft Tissue and Crestal Bone in One-Stage Implant Placement: A Randomized Controlled Trial
    Boora, Priyanka
    Rathee, Manu
    Bhoria, Mohaneesh
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (04) : ZC18 - ZC21
  • [27] Comparison of radiographic and histological assessment of peri-implant bone around oral implants
    Stokholm, Rie
    Spin-Neto, Rubens
    Nyengaard, Jens R.
    Isidor, Flemming
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (07) : 782 - 786
  • [28] The influence of thread geometry on implant osseointegration under immediate loading: a literature review
    Ryu, Hyo-Sook
    Namgung, Cheol
    Lee, Jong-Ho
    Lim, Young-Jun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (06) : 547 - 554
  • [29] Experimental models for peri-implant diseases: a narrative review
    Yin, Derong
    Zhan, Suying
    Liu, Yanbo
    Yan, Lichao
    Shi, Binmian
    Wang, Xiayi
    Zhang, Shiwen
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (07)
  • [30] Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys
    Romanos, G
    Toh, CG
    Siar, CH
    Swaminathan, D
    Ong, AH
    Donath, K
    Yaacob, H
    Nentwig, GH
    JOURNAL OF PERIODONTOLOGY, 2001, 72 (04) : 506 - 511