Influence of controlled immediate loading and implant design on peri-implant bone formation

被引:54
|
作者
Vandamme, Katleen
Naert, Ignace
Geris, Liesbet
Vander Sloten, Jozef
Puers, Robert
Duyck, Joke
机构
[1] Katholieke Univ Leuven, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Prosthet Dent,BIOMAT Res Grp, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Div Biomech & Engn Design, Louvain, Belgium
[3] Katholieke Univ Leuven, Dept Elect Engn, ESAT, MICAS, Louvain, Belgium
关键词
animal; bone chamber; immediate loading; implant macro-design; peri-implant healing;
D O I
10.1111/j.1600-051X.2006.01014.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. Material and Methods: A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. Results: A significantly higher bone area fraction was observed for SL compared with SU (p < 0.0001). The mineralized bone fraction was the highest for SL and significantly different from SU (p < 0.0001). The chance that osteoid- and bone-to-implant contact occurred was the highest for SL and significantly different from SU (p < 0.0001), but not from CL. When bone-to-implant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Conclusions: Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.
引用
收藏
页码:172 / 181
页数:10
相关论文
共 50 条
  • [1] Influence of immediate implant loading on peri-implant soft tissue morphology in the edentulous maxilla
    Gallucci, German O.
    Mavropoulos, Anestis
    Bernard, Jean-Pierre
    Belser, Urs C.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (04) : 595 - 602
  • [2] The influence of immediate occlusal loading on micro/nano-structure of peri-implant jaw bone in rats
    Yorioka, Hiroaki
    Otsu, Yuto
    Suzuki, Ryu
    Matsunaga, Satoru
    Nakano, Takayoshi
    Abe, Shinichi
    Sasaki, Hodaka
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [3] Effect of intermittent loading and surface roughness on peri-implant bone formation in a bone chamber model
    Duyck, Joke
    Slaets, Elke
    Sasaguri, Kenichi
    Vandamme, Katleen
    Naert, Ignace
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (11) : 998 - 1006
  • [4] The effect of loading on peri-implant bone: a critical review of the literature
    Duyck, J.
    Vandamme, K.
    JOURNAL OF ORAL REHABILITATION, 2014, 41 (10) : 783 - 794
  • [5] Relationship of Three-Dimensional Bone-to-Implant Contact to Primary Implant Stability and Peri-implant Bone Strain in Immediate Loading: Microcomputed Tomographic and In Vitro Analyses
    Hsu, Jui-Ting
    Huang, Heng-Li
    Chang, Chih-Han
    Tsai, Ming-Tzu
    Hung, Wei-Ching
    Fuh, Lih-Jyh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 367 - 374
  • [6] Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla
    Barbier, Lieven
    Abeloos, Johan
    De Clercq, Calix
    Jacobs, Reinhilde
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (04) : 1061 - 1070
  • [7] Na18F accumulates on the compressive side of peri-implant bone under immediate loading
    Miou Yamamoto
    Toru Ogawa
    Masayoshi Yokoyama
    Yoshihito Funaki
    Kenta Shobara
    Aya Shibamoto
    Juan Ramón Vanegas Sáenz
    Keiichi Sasaki
    Odontology, 2018, 106 : 232 - 237
  • [8] Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla
    Lieven Barbier
    Johan Abeloos
    Calix De Clercq
    Reinhilde Jacobs
    Clinical Oral Investigations, 2012, 16 : 1061 - 1070
  • [9] Na18F accumulates on the compressive side of peri-implant bone under immediate loading
    Yamamoto, Miou
    Ogawa, Toru
    Yokoyama, Masayoshi
    Funaki, Yoshihito
    Shobara, Kenta
    Shibamoto, Aya
    Saenz, Juan Ramon Vanegas
    Sasaki, Keiichi
    ODONTOLOGY, 2018, 106 (03) : 232 - 237
  • [10] Histologic and histomorphometric evaluation of peri-implant bone subjected to immediate loading:: An experimental study with Macaca fascicularis
    Romanos, GE
    Toh, CG
    Siar, CH
    Swaminathan, D
    Ong, AH
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2002, 17 (01) : 44 - 51