Direct neutron spectrum measurement to validate natZr(n,2n) reaction cross-section at 14 MeV

被引:0
作者
Murata, Isao [1 ]
Shiken, Kimiaki [1 ]
Kondo, Keitaro [2 ]
Matsunaka, Masayuki [1 ]
Ohta, Masayuki [1 ]
Miyamaru, Hiroyuki [1 ]
Ochiai, Kentaro [2 ]
Konno, Chikara [2 ]
Nishitani, Takeo [2 ]
机构
[1] Osaka Univ, Grad Sch Engn, Div Elect Elect & Informat Engn, Suita, Osaka 5650871, Japan
[2] Japan Atom Energy Agcy, Fus Res & Dev Directorate, Tokai, Ibaraki 3191195, Japan
关键词
Coincidence detection; DT neutron; (n; 2n); Cross-section; NE213; Zirconium;
D O I
10.1016/j.fusengdes.2009.02.053
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Lithium zirconate, Li2ZrO3, is known as a candidate blanket material in a fusion reactor. Various neutronics benchmark experiments for zirconium have thus been carried out so far. According to the independent benchmark studies by two parties, the neutron spectrum calculations show fairly large overestimation for most evaluated nuclear data libraries. However, the reason has not yet been made clear up to now. The author's group expects it would be due to a problem of evaluation for the Zr-nat(n,2n) reaction cross-section, because the cross-section measurement is basically not possible with the foil activation method for zirconium isotopes except for Zr-90. In the present study, two neutrons emitted from Zr-nat(n,2n) reaction have been measured directly to investigate the reason for the above overestimation. The measurement was done with our own special technique of detecting angle-correlated neutrons by the coincidence detection technique and the pencil-beam DT neutron source of FNS, JAEA. Angle-correlated energy differential cross-sections for Zr-nat(n,2n) reaction were successfully measured. The obtained total cross-section above the emitted neutron energy of 800 keV was fairly larger than the one evaluated in JENDL-3.3. The total cross-section of Zr-nat(n,2n) reaction was estimated by extrapolating the spectrum down to zero energy taking into account the nuclear temperature. The estimated cross-section value with the nuclear temperature of 1 MeV, which is larger than the one adopted in JENDL-3.3, was in acceptable agreement with JENDL-3.3. It is suggested from the result that the disagreement pointed out in the previous benchmark studies may be due to inappropriate nuclear temperature used in the evaluation. Further investigation of the nuclear temperature employed in the nuclear data evaluation should thus be carried out once again. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1376 / 1379
页数:4
相关论文
共 9 条
  • [1] BRIESMEISTER J. F., 2000, MCNP GEN MONTE CARLO
  • [2] Dickens J.K., 1988, SCINFUL: A Monte carlo based computer program to determine a scintillator full energy response to neutron detection for # between 0.1 and 80 MeV: User's Manual and FORTRAN Program Listing
  • [3] FREHAUT W, 1976, P 5 INT S INT FAST N, P17
  • [4] Measurement of leakage neutron spectra from a spherical pile of zirconium irradiated with 14 MeV neutrons and validation of its nuclear data
    Ichihara, C
    Kimura, I
    Hayashi, SA
    Yamamoto, J
    Takahashi, A
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2003, 40 (06) : 417 - 422
  • [5] JOHNSON RH, 1975, PSR92 ORNLRSIC
  • [6] MAEKAWA F, 2008, COMMUNICATION
  • [7] Angle-correlated spectrum measurement for two neutrons emitted from (n, 2n) reaction with the coincidence detection technique using a pencil-beam DT neutron source
    Murata, I.
    Takagi, S.
    Kondo, K.
    Shiken, K.
    Miyamaru, H.
    Mitsuda, M.
    Maekawa, F.
    Ochiai, K.
    Nishitani, T.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 595 (02) : 439 - 446
  • [8] Benchmark experiment on LiAlO2, Li2TiO3 and Li2ZrO3 assemblies with D-T neutrons-leakage neutron spectrum measurement
    Murata, I
    Nishio, T
    Kokooo
    Kondo, T
    Takagi, H
    Nakano, D
    Takahashi, A
    Maekawa, F
    Ikeda, Y
    Takeuchi, H
    [J]. FUSION ENGINEERING AND DESIGN, 2000, 51-52 : 821 - 827
  • [9] MURATA I, 2002, J NUCL SCI TECHNOL S, V2, P433