A study of CO2 storage integrity with rate allocation in multi-layered aquifer

被引:12
|
作者
Kim, Joohyung [1 ,2 ]
Song, Youngsoo [1 ]
Shinn, Youngjae [3 ]
Kwon, Yikyun [4 ]
Jung, Woodong [1 ]
Sung, Wonmo [1 ]
机构
[1] Hanyang Univ, Dept Nat Resources & Environm Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[2] KNOC, 305 Jongga Ro, Ulsan 44538, South Korea
[3] Korea Inst Geosci & Mineral Resources KIGAM, 124 Gwahak Ro, Daejeon 34132, South Korea
[4] Kongju Natl Univ, Dept Geoenvironm Sci, 56 Gongjudaehak Ro, Gongju Si 32588, Chungcheongnam, South Korea
关键词
CO2; injection; CO2 migration distance; leakage; deep saline aquifer; fault reactivating pressure; multi-layer; POHANG BASIN; FAULT; SITE;
D O I
10.1007/s12303-019-0004-0
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Most deep saline aquifers consist of multiple layers, and CO2 is generally injected through the injection well in a commingled form with one tubing string. Layer thicknesses and physical properties such as permeability and porosity vary from layer to layer because of differences in lithology and mineral compositions. When a heterogeneity such as a fault exists, if CO2 is rapidly introduced first into a certain layer, this CO2 reaches fault faster than other layers. Therefore, it is necessary to consider the characteristics of each layer in multi-layered aquifer, particularly in commingled well. In this study, rate allocation by layer was calculated in the multi-layered Pohang Basin aquifer, Korea, and whether CO2 reaches the fault and the pore pressure at the fault exceeds the fault reactivation pressure were investigated to evaluate the stability of the aquifer. In addition, the maximum CO2 storage capacity of the aquifer was estimated and we observed changes in trapping mechanisms over a 1,000-year period after the cessation of injection. The results of the analysis indicate that when up to 50 ktonnes of CO2 was injected into the Pohang Basin multi-layered aquifer over a two-year period, the rate allocations of the upper and lower layers were 70% and 30%, respectively. CO2 did not reach to the closest EF1 fault, and the pore pressure at this fault did not exceed the fault reopening pressure. The maximum possible storage capacity was conservatively calculated under the conditions of fault reactivation pressure (11.7 MPa) and maximum compressor capacity (14 MPa), indicating that a total of 160 ktonnes can be stably injected over six years without reaching the fault. In order to evaluate the stability of the aquifer, the changes in trapping mechanisms over a 1,000-year period were observed. According to the results, structural trapping decreased drastically, from 64.7% to 4.5%, over 1000 years. Meanwhile, solubility and residual trapping increased significantly, from 35.3% to 95.5%. Therefore, the data analyzed to date indicate that the project injecting CO2 in a commingled form from single tubing in the multi-layered Pohang Basin aquifer, Korea, has no possibility of CO2 leakage due to fault reopening.
引用
收藏
页码:823 / 832
页数:10
相关论文
共 50 条
  • [1] A study of CO2 storage integrity with rate allocation in multi-layered aquifer
    Joohyung Kim
    Youngsoo Song
    Youngjae Shinn
    Yikyun Kwon
    Woodong Jung
    Wonmo Sung
    Geosciences Journal, 2019, 23 : 823 - 832
  • [2] Multi-Layered Systems for Permanent Geologic Storage of CO2 at the Gigatonne Scale
    Kivi, I. R.
    Makhnenko, R. Y.
    Oldenburg, C. M.
    Rutqvist, J.
    Vilarrasa, V.
    GEOPHYSICAL RESEARCH LETTERS, 2022, 49 (24)
  • [3] Multi-layered fractured aquifer characterization: a comparative study
    Poduri, Sarada
    Kambhammettu, B. V. N. P.
    HYDROGEOLOGY JOURNAL, 2022, 30 (01) : 121 - 131
  • [4] Injection of CO2 into an aquifer for storage
    Hogstol, H
    GAS CYCLING: A NEW APPROACH, 1999, : 89 - 102
  • [5] Flow Dynamics of CO2/brine at the Interface Between the Storage Formation and Sealing Units in a Multi-layered Model
    Kim, Kue-Young
    Han, Weon Shik
    Oh, Junho
    Park, Eungyu
    Lee, Pyeong-Koo
    TRANSPORT IN POROUS MEDIA, 2014, 105 (03) : 611 - 633
  • [6] Mathematical modelling of a multi-layered alluvial aquifer
    Rushton, K.R.
    Tiwari, S.C.
    Journal of the Institution of Engineers (India): Civil Engineering Division, 1989, 70 (pt 2): : 47 - 54
  • [7] Adaptive Rate Allocation for Multi-layered Video Transmission in Wireless Communication Systems
    Xu, Jun
    Shen, Xuemin
    Mark, Jon W.
    Cai, Jun
    2006 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS, VOLS 1-12, 2006, : 5295 - 5300
  • [8] RADIOTRACER EVALUATION OF GROUNDWATER DISPERSION IN A MULTI-LAYERED AQUIFER
    MEYER, BR
    BAIN, CAR
    DEJESUS, ASM
    STEPHENSON, D
    JOURNAL OF HYDROLOGY, 1981, 50 (1-3) : 259 - 271
  • [9] CO2 storage in heterogeneous aquifer: A study on the effect of injection rate and CaCO3 concentration
    Raza, A.
    Rezaee, R.
    Bing, C. H.
    Gholami, R.
    Nagarajan, R.
    Hamid, M. A.
    10TH CURTIN UNIVERSITY TECHNOLOGY SCIENCE AND ENGINEERING INTERNATIONAL CONFERENCE (CUTSE2015), 2016, 121
  • [10] Experimental study of wellbore integrity for CO2 geological storage
    Recasens, M.
    Garcia, S.
    Mackay, E.
    Delgado, J.
    Maroto-Valer, M. M.
    13TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-13, 2017, 114 : 5249 - 5255