The impact of peak-kilovoltage settings on heterogeneity-corrected photon-beam treatment plans

被引:5
作者
Kendall, Robin L. [1 ]
Gifford, Kent A. [1 ]
Kirsner, Steven M. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Unit 94, Houston, TX 77030 USA
关键词
CT tube potential; hounsfield unit; electron density; photon-beam treatment planning; heterogeneity corrections;
D O I
10.1016/j.radonc.2006.10.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Differences were evaluated in external-beam treatment plan dose calculations that result from the use of different Hounsfield-unit to electron-density conversion curves with CT images acquired with various tube potentials. These differences were found to be clinically insignificant and it was concluded that the impact of CT tube potential on treatment planning is negligible. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:206 / 208
页数:3
相关论文
共 16 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]   Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients [J].
Cody, DD ;
Moxley, DM ;
Krugh, KT ;
O'Daniel, JC ;
Wagner, LK ;
Eftekhari, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) :849-859
[3]   AN ELECTRON-DENSITY CALIBRATION PHANTOM FOR CT-BASED TREATMENT PLANNING COMPUTERS [J].
CONSTANTINOU, C ;
HARRINGTON, JC ;
DEWERD, LA .
MEDICAL PHYSICS, 1992, 19 (02) :325-327
[4]   Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy [J].
Cozzi, L ;
Fogliata, A ;
Buffa, F ;
Bieri, S .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) :335-338
[5]   The indirect use of CT numbers to establish material properties needed for Monte Carlo calculation of dose distributions in patients [J].
du Plessis, FCP ;
Willemse, CA ;
Lotter, MG ;
Goedhals, L .
MEDICAL PHYSICS, 1998, 25 (07) :1195-1201
[6]   USE OF CT SCANNERS IN MEGAVOLTAGE PHOTON-BEAM THERAPY PLANNING [J].
GEISE, RA ;
MCCULLOUGH, EC .
RADIOLOGY, 1977, 124 (01) :133-141
[7]   Accuracy of inhomogeneity correction in photon radiotherapy from CT scans with different settings [J].
Guan, HQ ;
Yin, FF ;
Kim, JH .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (17) :N223-N231
[8]   Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[9]   Dose and image quality. How does the choice of kilovoltage affect patient dose, scattered radiation, and image quality in CT examinations? Submitted by Glen Thomson, Middlemore Hospital, New Zealand [J].
Huda, W .
PEDIATRIC RADIOLOGY, 2004, 34 (02) :185-185
[10]  
ICRU, 24 ICRU