Large-Cohort Comparison Between Three-Dimensional Time-of-Flight Magnetic Resonance and Rotational Digital Subtraction Angiographies in Intracranial Aneurysm Detection

被引:62
作者
Li, Ming-Hua [1 ]
Cheng, Ying-Sheng [1 ]
Li, Yong-Dong [1 ]
Fang, Chun [1 ]
Chen, Shi-Wen [1 ]
Wang, Wu [1 ]
Hu, Ding-Jun [1 ]
Xu, Hao-Wen [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Diagnost & Intervent Radiol, Affiliated Peoples Hosp 6, Shanghai 200030, Peoples R China
关键词
digital subtraction angiography; intracranial aneurysm; magnetic resonance angiography; volume rendering; MR-ANGIOGRAPHY;
D O I
10.1161/STROKEAHA.109.553800
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-The value of MR angiography varies in diagnosis of intracranial aneurysms due to the difference of equipment and imaging technique. This study was to compare the effectiveness of 3-dimensional time-of-flight MR angiography at 3 T and rotational digital subtraction angiography, both with volume rendering (VR), in detecting intracranial aneurysms. Methods-One hundred thirty-eight patients with suspected or known aneurysms and other cerebral vascular diseases detected by MR angiography underwent digital subtraction angiography examinations. Postprocessing techniques, including VR and the single artery highlighting method, were performed by a 3-dimensional specialist. The VR-digital subtraction angiography was obtained as the gold standard. Results-The rotational digital subtraction angiography and VR-digital subtraction angiography revealed 146 aneurysms in 122 patients and no aneurysms in 16 patients. Of the 276 vessels examined, 136 vessels had 146 aneurysms and 140 vessels had none. Per vessel and per aneurysm sensitivities were 100%, whereas the per vessel accuracy ranged from 97.5% to 98.6% and the per aneurysm accuracy ranged from 95.1% to 97.0%. Conclusions-VR 3-dimensional time-of-flight MR angiography at 3 T has excellent sensitivity, accuracy, and correlation with VR-digital subtraction angiography and is comparable to catheter cerebral angiography for the evaluation of patients with intracranial aneurysms who tolerate MR angiography well. (Stroke. 2009; 40: 3127-3129.)
引用
收藏
页码:3127 / 3129
页数:3
相关论文
共 7 条
[1]   Intracranial aneurysms: Detection and characterization with MR angiography with use of an advanced postprocessing technique in a blinded-reader study [J].
Atlas, SW ;
Sheppard, L ;
Goldberg, HI ;
Hurst, RW ;
Listerud, J ;
Flamm, E .
RADIOLOGY, 1997, 203 (03) :807-814
[2]   Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation - A meta-analysis [J].
Cloft, HJ ;
Joseph, GJ ;
Dion, JE .
STROKE, 1999, 30 (02) :317-320
[3]   Diagnostic accuracy of magnetic resonance angiography for cerebral aneurysms in correlation with 3D-digital subtraction angiographic images - A study of 133 aneurysms [J].
Okahara, M ;
Kiyosue, H ;
Yamashita, M ;
Nagatomi, H ;
Hata, H ;
Saginoya, T ;
Sagara, Y ;
Mori, H .
STROKE, 2002, 33 (07) :1803-1808
[4]  
Sim J, 2005, PHYS THER, V85, P257
[5]  
Sugahara T, 2002, AM J NEURORADIOL, V23, P1545
[6]   3D rotational angiography: The new gold standard in the detection of additional intracranial aneurysms [J].
van Rooij, W. J. ;
Sprengers, M. E. ;
de Gast, A. N. ;
Peluso, J. P. P. ;
Sluzewski, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (05) :976-979
[7]   Intracranial aneurysms: CT angiography and MR angiography for detection - Prospective blinded comparison in a large patient cohort [J].
White, PM ;
Teasdale, EM ;
Wardlaw, JM ;
Easton, V .
RADIOLOGY, 2001, 219 (03) :739-749