Can real-time RGBD enhance intraoperative Cone-Beam CT?

被引:13
|
作者
Fotouhi, Javad [1 ]
Fuerst, Bernhard [1 ]
Wein, Wolfgang [2 ]
Navab, Nassir [1 ,3 ]
机构
[1] Johns Hopkins Univ, Comp Aided Med Procedures, Baltimore, MD 21218 USA
[2] ImFusion GmbH, Munich, Germany
[3] Tech Univ Munich, Comp Aided Med Procedures, Munich, Germany
基金
美国国家卫生研究院;
关键词
Cone-Beam CT; RGBD; Intraoperative; Tomographic reconstruction; MLEM; Algebraic reconstruction; ALGEBRAIC RECONSTRUCTION; IMAGE-RECONSTRUCTION; CAMERA; CALIBRATION; MOTION;
D O I
10.1007/s11548-017-1572-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Cone-Beam Computed Tomography (CBCT) is an important 3D imaging technology for orthopedic, trauma, radiotherapy guidance, angiography, and dental applications. The major limitation of CBCT is the poor image quality due to scattered radiation, truncation, and patient movement. In this work, we propose to incorporate information from a co-registered Red-Green-Blue-Depth (RGBD) sensor attached near the detector plane of the C-arm to improve the reconstruction quality, as well as correcting for undesired rigid patient movement. Methods Calibration of the RGBD and C-arm imaging devices is performed in two steps: (i) calibration of the RGBD sensor and the X-ray source using a multimodal checkerboard pattern, and (ii) calibration of the RGBD surface reconstruction to the CBCT volume. The patient surface is acquired during the CBCT scan and then used as prior information for the reconstruction using Maximum-Likelihood Expectation-Maximization. An RGBD-based simultaneous localization and mapping method is utilized to estimate the rigid patient movement during scanning. Results Performance is quantified and demonstrated using artificial data and bone phantoms with and without metal implants. Finally, we present movement-corrected CBCT reconstructions based on RGBD data on an animal specimen, where the average voxel intensity difference reduces from 0.157 without correction to 0.022 with correction. Conclusion This work investigated the advantages of a C-arm X-ray imaging system used with an attached RGBD sensor. The experiments show the benefits of the opto/X-ray imaging system in: (i) improving the quality of reconstruction by incorporating the surface information of the patient, reducing the streak artifacts as well as the number of required projections, and (ii) recovering the scanning trajectory for the reconstruction in the presence of undesired patient rigid movement.
引用
收藏
页码:1211 / 1219
页数:9
相关论文
共 50 条
  • [41] Comparison of intraoperative cone-beam CT versus preoperative fan-beam CT for navigated spine surgery: a prospective randomized study
    Tu, Tsung-Hsi
    Kuo, Yi-Hsuan
    Chang, Chih-Chang
    Kuo, Chao -Hung
    Chang, Hsuan-Kan
    Fay, Li-Yu
    Yeh, Mei-Yin
    Ko, Chin -Chu
    Huang, Wen-Cheng
    Wu, Jau-Ching
    JOURNAL OF NEUROSURGERY-SPINE, 2024, 40 (02) : 240 - 247
  • [42] Intraoperative cone-beam CT for correction of periaxial malrotation of the femoral shaft: A surface-matching approach
    Khoury, Amal
    Whyne, Cari M.
    Daly, Michael
    Moseley, Douglas
    Bootsma, Greg
    Skrinskas, Tomas
    Siewerdsen, Jeffrey
    Jaffray, David
    MEDICAL PHYSICS, 2007, 34 (04) : 1380 - 1387
  • [43] Truncation effect reduction for fast iterative reconstruction in cone-beam CT
    Aootaphao, Sorapong
    Thongvigitmanee, Saowapak S.
    Puttawibul, Puttisak
    Thajchayapong, Pairash
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [44] Dual-energy approach to reduce cone-beam artefacts in a circular orbit cone-beam CT system
    Han, C.
    Baek, J.
    ELECTRONICS LETTERS, 2020, 56 (13) : 648 - 650
  • [45] Quantitative cone-beam CT reconstruction with polyenergetic scatter model fusion
    Mason, Jonathan H.
    Perelli, Alessandro
    Nailon, William H.
    Davies, Mike E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (22)
  • [46] Feasibility of Cone-beam CT based treatment planning
    Yoo, S.
    Yin, F.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1831 - 1834
  • [47] Spatial resolution of iterative cone-beam CT reconstruction
    Nielsen, T
    Köhler, T
    Proksa, R
    van Stevendaal, U
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3253 - 3256
  • [48] Advanced cone-beam CT venous angiographic imaging
    Srinivasan, Visish M.
    Chintalapani, Gouthami
    Duckworth, Edward A. M.
    Kan, Peter
    JOURNAL OF NEUROSURGERY, 2018, 129 (01) : 114 - 120
  • [49] Evaluation of Dose Calculation Based On Cone-Beam CT
    Abe, T.
    Tateoka, K.
    Fujimoto, K.
    Nakazawa, T.
    Saitou, Y.
    Nakata, A.
    Yano, M.
    Sakata, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 259 - 259
  • [50] Image quality of flat panel cone-beam CT
    Rose, G
    Wiegert, J
    Schäfer, D
    Fiedler, K
    Conrads, N
    Timmer, J
    Rasche, V
    Noordhoek, N
    Klotz, E
    Koppe, R
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 677 - 683