Can real-time RGBD enhance intraoperative Cone-Beam CT?

被引:13
|
作者
Fotouhi, Javad [1 ]
Fuerst, Bernhard [1 ]
Wein, Wolfgang [2 ]
Navab, Nassir [1 ,3 ]
机构
[1] Johns Hopkins Univ, Comp Aided Med Procedures, Baltimore, MD 21218 USA
[2] ImFusion GmbH, Munich, Germany
[3] Tech Univ Munich, Comp Aided Med Procedures, Munich, Germany
基金
美国国家卫生研究院;
关键词
Cone-Beam CT; RGBD; Intraoperative; Tomographic reconstruction; MLEM; Algebraic reconstruction; ALGEBRAIC RECONSTRUCTION; IMAGE-RECONSTRUCTION; CAMERA; CALIBRATION; MOTION;
D O I
10.1007/s11548-017-1572-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Cone-Beam Computed Tomography (CBCT) is an important 3D imaging technology for orthopedic, trauma, radiotherapy guidance, angiography, and dental applications. The major limitation of CBCT is the poor image quality due to scattered radiation, truncation, and patient movement. In this work, we propose to incorporate information from a co-registered Red-Green-Blue-Depth (RGBD) sensor attached near the detector plane of the C-arm to improve the reconstruction quality, as well as correcting for undesired rigid patient movement. Methods Calibration of the RGBD and C-arm imaging devices is performed in two steps: (i) calibration of the RGBD sensor and the X-ray source using a multimodal checkerboard pattern, and (ii) calibration of the RGBD surface reconstruction to the CBCT volume. The patient surface is acquired during the CBCT scan and then used as prior information for the reconstruction using Maximum-Likelihood Expectation-Maximization. An RGBD-based simultaneous localization and mapping method is utilized to estimate the rigid patient movement during scanning. Results Performance is quantified and demonstrated using artificial data and bone phantoms with and without metal implants. Finally, we present movement-corrected CBCT reconstructions based on RGBD data on an animal specimen, where the average voxel intensity difference reduces from 0.157 without correction to 0.022 with correction. Conclusion This work investigated the advantages of a C-arm X-ray imaging system used with an attached RGBD sensor. The experiments show the benefits of the opto/X-ray imaging system in: (i) improving the quality of reconstruction by incorporating the surface information of the patient, reducing the streak artifacts as well as the number of required projections, and (ii) recovering the scanning trajectory for the reconstruction in the presence of undesired patient rigid movement.
引用
收藏
页码:1211 / 1219
页数:9
相关论文
共 50 条
  • [31] Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization
    Sing Chun Lee
    Bernhard Fuerst
    Javad Fotouhi
    Marius Fischer
    Greg Osgood
    Nassir Navab
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 967 - 975
  • [32] A Novel CT to Cone-Beam CT Registration Method Enables Immediate Real-Time Intraprocedural Three-Dimensional Assessment of Ablative Treatments of Liver Malignancies
    Solbiati, Marco
    Passera, Katia M.
    Goldberg, S. Nahum
    Rotilio, Alessandro
    Ierace, Tiziana
    Pedicini, Vittorio
    Poretti, Dario
    Solbiati, Luigi
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (07) : 1049 - 1057
  • [33] Automated ultrafast kilovoltage-megavoltage cone-beam CT for image guided radiotherapy of lung cancer: System description and real-time results
    Blessing, Manuel
    Arns, Anna
    Wertz, Hansjoerg
    Stsepankou, Dzmitry
    Boda-Heggemann, Judit
    Hesser, Juergen
    Wenz, Frederik
    Lohr, Frank
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 110 - 120
  • [34] Physical performance and image optimization of megavoltage cone-beam CT
    Morin, Olivier
    Aubry, Jean-Francois
    Aubin, MichSle
    Chen, Josephine
    Descovich, Martina
    Hashemi, Ali-Bani
    Pouliot, Jean
    MEDICAL PHYSICS, 2009, 36 (04) : 1421 - 1432
  • [35] OR-EM Method for Image Reconstruction in Cone-beam CT
    Dong, Baoyu
    PROCEEDINGS OF THE FIRST INTERNATIONAL WORKSHOP ON EDUCATION TECHNOLOGY AND COMPUTER SCIENCE, VOL I, 2009, : 635 - 639
  • [36] Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization
    Lee, Sing Chun
    Fuerst, Bernhard
    Fotouhi, Javad
    Fischer, Marius
    Osgood, Greg
    Navab, Nassir
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (06) : 967 - 975
  • [37] Improvement of Time-Ordered Four Dimensional Cone-Beam CT; Image Mosaicing with Real and Virtual Projections
    Nakano, M.
    Kida, S.
    Masutani, Y.
    Shiraki, T.
    Yamamoto, K.
    Shiraishi, K.
    Nakagawa, K.
    Haga, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 195 - +
  • [38] Orthogonal-rotating tetrahedral scanning for cone-beam CT
    Ye, Ivan B.
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [39] Cone-beam CT reconstruction for planar object
    Liu, Tong
    NDT & E INTERNATIONAL, 2012, 45 (01) : 9 - 15
  • [40] A motion-compensated cone-beam CT using electrical impedance tomography imaging
    Pengpan, T.
    Smith, N. D.
    Qiu, W.
    Yao, A.
    Mitchell, C. N.
    Soleimani, M.