Fetal-maternal hemorrhage detection in Ontario

被引:14
作者
Lafferty, JD
Raby, A
Crawford, L
Linkins, LA
Richardson, H
Crowther, M
机构
[1] Qual Management Program Lab Serv, Toronto, ON M4W 1E6, Canada
[2] Hamilton Reg Lab Med Program, Hamilton, ON, Canada
[3] McMaster Univ, Dept Med, Hamilton, ON, Canada
关键词
hemolytic disease of the newborn; fetal-maternal hemorrhage detection; Rh-o(D) immune globulin; Kleihauer-Betke stain; rosette technique; Nierhaus stain;
D O I
10.1309/3U97V7327JBDPAYN
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The results from fetal-maternal hemorrhage (FMH) detection and quantitation external quality assessment surveys conducted in Ontario indicate that the rosette test had a sensitivity and specificity for an FMH of more than 10 mL of 1.0 and 0.75, respectively, compared with 0.96 and 0.92, respectively, for acid elution. With FMH quantitation, the percentage error of the mean from the target FMH was 20% or more in 7 of 8 surveys, and coefficients of variation ranged from 39.5% to 71.8%. Inadequate Rho(D) immune globulin prophylaxis could have occurred in 19.4% of the challenges with an FMH of more than 10 mL. The rosette and acid elution techniques are both effective for the detection or exclusion of FMH, but acid elution lacks adequate accuracy and precision for reliable FMH quantitation. Furthermore, a strategy of prescribing an extra 1,500-IU Rh-o(D) immune globulin dose, in addition to the dose required to treat the volume offetal blood detected, is an effective strategy to overcome the limitations of FMH quantitation by acid elution.
引用
收藏
页码:72 / 77
页数:6
相关论文
共 17 条
  • [1] Detection of fetal red cells in fetomaternal hemorrhage using a fetal hemoglobin monoclonal antibody by flow cytometry
    Davis, BH
    Olsen, S
    Bigelow, NC
    Chen, JC
    [J]. TRANSFUSION, 1998, 38 (08) : 749 - 756
  • [2] Davis BH, 2001, CLIN LAB MED, V21, P829
  • [3] The Kleihauer technique: An accurate method of quantifying fetomaternal haemorrhage?
    Duckett, JRA
    Constantine, G
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (07): : 845 - 846
  • [4] Duguid JKM, 1999, TRANSFUS MED REV, V13, P43
  • [5] Detection of massive transplacental haemorrhage by flow cytometry
    Fong, EA
    Davies, JI
    Grey, DE
    Reid, PJ
    Erber, WN
    [J]. CLINICAL AND LABORATORY HAEMATOLOGY, 2000, 22 (06): : 325 - 327
  • [6] Use of Rh immune globulin - ASCP practice parameter
    Hartwell, EA
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 110 (03) : 281 - 292
  • [7] DEMONSTRATION VON FETALEM HAMOGLOBIN IN DEN ERYTHROCYTEN EINES BLUTAUSSTRICHS
    KLEIHAUER, E
    BRAUN, H
    BETKE, K
    [J]. KLINISCHE WOCHENSCHRIFT, 1957, 35 (12): : 637 - 638
  • [8] Labeling D+ RBCs for flow cytometric quantification of fetomaternal hemorrhage after the RBCs have been coated with anti-D
    Kumpel, BM
    [J]. TRANSFUSION, 2001, 41 (08) : 1059 - 1063
  • [9] Nelson M, 1994, Immunohematology, V10, P55
  • [10] NESS PM, 1981, RH HEMOLYTIC DIS NEW, P135