Dosimetric assessment of a single-energy metal artifact reduction algorithm for computed tomography images in radiation therapy

被引:7
作者
Murazaki, Hiroo [1 ]
Fukunaga, Junichi [1 ]
Hirose, Taka-aki [1 ]
Funatsu, Naomi [1 ]
Matsumoto, Ryoji [1 ]
Hidaka, Kyohei [1 ]
Nagamine, Shuji [1 ]
Nakanishi, Daiki [1 ]
Kato, Toyoyuki [1 ]
机构
[1] Kyushu Univ Hosp, Dept Med Technol, Div Radiol, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
关键词
Metal artifact reduction; Single-energy metal artifact reduction; Radiation treatment planning; Dose distribution; ANISOTROPIC ANALYTICAL ALGORITHM; ACUROS XB; DOSE CALCULATION; CT; QUALITY; IMPACT; SIMULATION; AAA;
D O I
10.1007/s12194-019-00517-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed to evaluate the performance of a single-energy metal artifact reduction (SEMAR) algorithm for radiation therapy treatment using phantom cases with metal inserts, assess improvements in computed tomography (CT) number accuracy, and investigate its effects on treatment planning dosimetry. A standard electron density phantom was scanned with and without metal inserts. The numbers of tissue-equivalent materials on both uncorrected and SEMAR-corrected CT images were compared. Treatment planning accuracy was evaluated by comparing dose distributions computed using true density images (without metal inserts), uncorrected images (with metal inserts), and SEMAR-corrected images (with metal inserts) using three-dimensional gamma analysis. The numbers of the true density and uncorrected and SEMAR-corrected CT images in a muscle plug with unilateral inserts were 25.9 HU, - 281.8 HU, and 26.1 HU, respectively. A similar tendency was obtained for other tissue-equivalent materials, and the numbers on CT images were improved with the SEMAR algorithm. In cases involving 1 portal irradiation, 10-MV X-ray, and the Acuros XB algorithm, the pass ratio between the true density and uncorrected images was 89.89%, while that between the true density and SEMAR-corrected images was 95.03%. Improvements in dose distribution were evident using the SEMAR algorithm. Similar trends were found for different irradiation methods and dose calculation algorithms. The SEMAR algorithm can significantly reduce metal artifacts on CT images used for radiation treatment planning. This aspect influenced dosimetry in the region of the artifact and dose distribution was significantly improved with use of the SEMAR-corrected images.
引用
收藏
页码:268 / 276
页数:9
相关论文
共 50 条
  • [41] Quality improvement of images with metal artifact reduction using a noise recovery technique in computed tomography
    Morioka, Yusuke
    Ichikawa, Katsuhiro
    Kawashima, Hiroki
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (01) : 169 - 180
  • [42] Quality improvement of images with metal artifact reduction using a noise recovery technique in computed tomography
    Yusuke Morioka
    Katsuhiro Ichikawa
    Hiroki Kawashima
    [J]. Physical and Engineering Sciences in Medicine, 2024, 47 : 169 - 180
  • [43] Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm
    Fang-ling Zhang
    Ruo-cheng Li
    Xiao-ling Zhang
    Zhao-hui Zhang
    Ling Ma
    Lei Ding
    [J]. BMC Cancer, 21
  • [44] Quantifying near metal visibility using dual energy computed tomography and iterative metal artifact reduction in a fracture phantom
    Hakvoort, E. T.
    Wellenberg, R. H. H.
    Streekstra, G. J.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 9 - 18
  • [45] Comprehensive assessments of the open mouth dynamic maneuver and metal artifact reduction algorithm on computed tomography images of the oral cavity and oropharynx
    Bae, Yun Jung
    Kim, Tae Eun
    Choi, Byung Se
    Jeong, Woo-Jin
    Cho, Se Jin
    Baik, Sung Hyun
    Sunwoo, Leonard
    Kim, Jae Hyoung
    [J]. PLOS ONE, 2021, 16 (03):
  • [46] Normalized Metal Artifact Reduction in Head and Neck Computed Tomography
    Lell, Michael M.
    Meyer, Esther
    Kuefner, Michael A.
    May, Matthias S.
    Raupach, Rainer
    Uder, Michael
    Kachelriess, Marc
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (07) : 415 - 421
  • [47] Adaptive Normalized Metal Artifact Reduction (ANMAR) in Computed Tomography
    Meyer, Esther
    Raupach, Rainer
    Schmidt, Bernhard
    Mahnken, Andreas H.
    Kachelriess, Marc
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2560 - 2565
  • [48] Metal Artifact Reduction: Standard and Advanced Magnetic Resonance and Computed Tomography Techniques
    Gupta, Amit
    Subhas, Naveen
    Primak, Andrew N.
    Nittka, Mathias
    Liu, Kecheng
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2015, 53 (03) : 531 - +
  • [49] A fully 3D approach for metal artifact reduction in computed tomography
    Kratz, Baerbel
    Weyers, Imke
    Buzug, Thorsten M.
    [J]. MEDICAL PHYSICS, 2012, 39 (11) : 7042 - 7054
  • [50] A Normalized Metal Artifact Reduction Method Using an Artifact-Reduced Prior for Dental Computed Tomography
    Park, Chulkyu
    Lee, Dongyeon
    Lim, Younghwan
    Kim, Guna
    Kim, Kyuseok
    Cho, Hyosung
    Seo, Changwoo
    Lim, Hyunwoo
    Lee, Hunwoo
    Park, Soyoung
    Kang, Seokyoon
    Park, Jeongeun
    Jeon, Duhee
    Kim, Woosung
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (03) : 298 - 304