Use of automated home blood pressure monitoring in pregnancy: Is it safe?

被引:35
|
作者
Lo, C
Taylor, RS
Gamble, G
McCowan, L
North, RA
机构
[1] Univ Auckland, Dept Obstet & Gynecol, Auckland 1, New Zealand
[2] Univ Auckland, Dept Med, Auckland 1, New Zealand
关键词
blood pressure monitoring; oscillometric monitor; pregnancy; preeclampsia;
D O I
10.1067/mob.2002.126847
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: The purpose of this study was to investigate the relationship between blood pressure that is measured with the automated blood pressure monitor, Omron HEM-705CP (Omron Corporation, Tokyo, Japan), and mercury sphygmomanometry in normotensive and preeclamptic pregnant women. STUDY DESIGN: Healthy pregnant women (n = 101 women) underwent mercury and home Omron HEM-705CP monitor blood pressure measurements at 10 to 14, 19 to 22, 27 to 30, and 35 to 37 weeks of gestation and 5 to 9 weeks after delivery. After routine mercury blood pressure recordings that were taken by midwives, women with preeclampsia (n = 45 women) measured their own blood pressure using an Omron HEM-705CP monitor (n = 212 recordings). In the longitudinal cohort, mean +/- 2 SD were calculated for blood pressure levels throughout pregnancy. Individual variation in home Omron minus office mercury throughout pregnancy was determined. In preeclampsia, back-to-back blood pressure measurements by the two methods were correlated and quantified as being within 5, 10, and 15 mm Hg. Bland-Altman plots were calculated, and the sensitivity of the Omron HEM-705CP monitor to detect hypertension that was identified by mercury sphygmomanometry was evaluated. RESULTS: At 10 to 14, 19 to 22, 27 to 30, and 35 to 37 weeks of gestation, the upper limits for normal systolic blood pressure levels with the use of home Omron HEM-705CP monitor measurements were 132, 130, 133, and 138 mm Hg and for diastolic blood pressure levels were 82, 79, 81, and 88 mm Hg, respectively. For women who were normotensive and had preeclampsia (although group mean blood pressure values by mercury sphygmomanometry and Omron HEM-705CP monitor were similar), there were marked individual differences (! 40 mm Hg) between the devices. In preeclampsia, paired Omron monitor and mercury systolic and diastolic blood pressure levels were within 5, 10, and 15 mm Hg in 47%, 73%, and 82%, and 56%, 78%, and 92%, respectively. The Omron monitor identified > 90% of mild hypertension (140/90 mm Hg) but missed one third of hypertension with a blood pressure level of > 160/100 mm Hg by mercury sphygmomanometry. CONCLUSION: Clinicians should be aware of the potential differences between blood pressure measurements with mercury sphygmomanometers and Omron HEM-705CP monitors in pregnancy. The Omron HEM-705CP monitor should not be used to monitor hypertension in preeclampsia.
引用
收藏
页码:1321 / 1328
页数:8
相关论文
共 50 条
  • [21] Tele-monitoring of home blood pressure
    Mengden, T
    Vetter, H
    Tislér, A
    Illyés, M
    BLOOD PRESSURE MONITORING, 2001, 6 (04) : 185 - 189
  • [22] Implementation of a home blood pressure monitoring program for the management of hypertensive disorders of pregnancy, an observational study in British Columbia, Canada
    Tran, Karen C.
    Freiman, Sabina
    Chaworth-Musters, Tessa
    Purkiss, Susan
    Foster, Colleen
    Khan, Nadia A.
    Chan, Wee Shian
    OBSTETRIC MEDICINE, 2024, 17 (01) : 22 - 27
  • [23] SAFE@HOME - Feasibility study of a telemonitoring platform combining blood pressure and preeclampsia symptoms in pregnancy care
    van den Heuvel, Josephus F. M.
    Kariman, Shariva S.
    van Solinge, Wouter W.
    Franx, Arie
    Lely, A. Titia
    Bekker, Mireille N.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2019, 240 : 226 - 231
  • [24] Provisional criteria for the diagnosis of hypertension in pregnancy using home blood pressure measurements
    Mikami, Yukiko
    Takai, Yasushi
    Era, Sumiko
    Ono, Yoshihisa
    Saitoh, Masahiro
    Baba, Kazunori
    Suzuki, Hiromichi
    Seki, Hiroyuki
    HYPERTENSION RESEARCH, 2017, 40 (07) : 679 - 684
  • [25] Assessment of Resistant Hypertension with Home Blood Pressure Monitoring
    Marui, Fabiane Rosa Rezende H.
    Nogueira Bombig, Maria Teresa
    Francisco, Yona Afonso
    Thalenberg, Jose Marcos
    Helfenstein Fonseca, Francisco Antonio
    de Souza, Dima
    Costa, Francisco de Assis
    Izar, Maria Cristina
    de Camargo Carvalho, Antonio Carlos
    Povoa, Rui
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2010, 95 (04) : 536 - 540
  • [26] Multiple clinic and home blood pressure measurements versus ambulatory blood pressure monitoring
    Jula, A
    Puukka, P
    Karanko, H
    HYPERTENSION, 1999, 34 (02) : 261 - 266
  • [27] Postpartum Home Blood Pressure Monitoring A Systematic Review
    Steele, Dale W.
    Adam, Gaelen P.
    Saldanha, Ian J.
    Kanaan, Ghid
    Zahradnik, Michael L.
    Danilack-Fekete, Valery A.
    Stuebe, Alison M.
    Peahl, Alex F.
    Chen, Kenneth K.
    Balk, Ethan M.
    OBSTETRICS AND GYNECOLOGY, 2023, 142 (02) : 285 - 295
  • [28] Home Blood Pressure Monitoring in Clinical Practice: A Review
    Mallick, Salman
    Kanthety, Radhika
    Rahman, Mahboob
    AMERICAN JOURNAL OF MEDICINE, 2009, 122 (09) : 803 - 810
  • [29] Defining Thresholds for Home Blood Pressure Monitoring in Octogenarians
    Aparicio, Lucas S.
    Thijs, Lutgarde
    Boggia, Jose
    Jacobs, Lotte
    Barochiner, Jessica
    Odili, Augustine N.
    Alfie, Jose
    Asayama, Kei
    Cuffaro, Paula E.
    Nomura, Kyoko
    Ohkubo, Takayoshi
    Tsuji, Ichiro
    Stergiou, George S.
    Kikuya, Masahiro
    Imai, Yutaka
    Waisman, Gabriel D.
    Staessen, Jan A.
    HYPERTENSION, 2015, 66 (04) : 865 - 873
  • [30] AUTOMATED 24-HOUR AMBULATORY BLOOD-PRESSURE MONITORING IN PREECLAMPSIA
    MONTAN, S
    CHOOLANI, M
    ARULKUMARAN, S
    RATNAM, SS
    JOURNAL OF PERINATAL MEDICINE, 1995, 23 (05) : 353 - 358