A PCM/heat pipe cooling system for reducing air conditioning in buildings: review of options and report on field tests

被引:22
|
作者
Etheridge, D. [1 ]
Murphy, K. [1 ]
Reay, D. [1 ]
机构
[1] Univ Nottingham, Sch Built Environm, Nottingham NG7 2RD, England
关键词
D O I
10.1191/0143624406bt142oa
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air conditioning is now seen as a new and major contributor to CO2 emissions in the UK. This is partly due to global warming and partly to the increased use of IT systems. A novel system for reducing or eliminating the need for air conditioning was developed to the proof-of-concept stage under an earlier project at the University of Nottingham. The system makes use of heat pipes to transfer heat into and out of a phase change material which is 'frozen' during the night and 'melted' during the day. This paper describes a number of concepts for 'free cooling', and the background to the current concept, before detailing field tests on the system that have recently been completed and which demonstrate its effectiveness under real operating conditions. Systems were installed in two offices and detailed monitoring of their performance was carried out during the summer months. On the basis of the results obtained it is concluded that the system functions very well and is practically and technically the most attractive of the available alternatives to air conditioning. The fact that it is suited to retrofitting in existing buildings means that both the potential market and the CO2 reductions are large. Practical application: The paper describes a novel system that is intended to provide passive cooling in naturally ventilated buildings. The novelty lies in the use of heat pipes and a fan to enhance the heat transfer to and from the phase change material (PCM) and the air. That this has been successful is shown by the ability of the system to exercise a degree of control over the room air temperature that is comparable to that of a conventional airconclitioning system. The review provided in the paper may also be of use to other workers on PCMs and night cooling of naturally ventilated buildings.
引用
收藏
页码:27 / 39
页数:13
相关论文
共 50 条
  • [1] The Review of the Application of the Heat Pipe on Enhancing Performance of the Air-Conditioning System in Buildings
    Yuan, Tianhao
    Liu, Zeyu
    Zhang, Linlin
    Dong, Suiju
    Zhang, Jilong
    PROCESSES, 2023, 11 (11)
  • [2] Review of heat pipe heat exchangers for enhanced dehumidification and cooling in air conditioning systems
    Ong, K. S.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2016, 11 (03) : 416 - 423
  • [3] Secondary heat recovery heat pipe air conditioning system
    Zhou Z.
    Wu Q.
    Wei Z.
    Li C.
    Huagong Xuebao/CIESC Journal, 2017, 68 (05): : 1823 - 1832
  • [4] A review on the air-PCM-TES application for free cooling and heating in the buildings
    Iten, Muriel
    Liu, Shuli
    Shukla, Ashish
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 61 : 175 - 186
  • [5] Novel ventilation cooling system for reducing air conditioning in buildings. Part I: testing and theoretical modelling
    Turnpenny, JR
    Etheridge, DW
    Reay, DA
    APPLIED THERMAL ENGINEERING, 2000, 20 (11) : 1019 - 1037
  • [6] Energy efficient PCM-based variable air volume air conditioning system for modern buildings
    Parameshwaran, R.
    Harikrishnan, S.
    Kalaiselvam, S.
    ENERGY AND BUILDINGS, 2010, 42 (08) : 1353 - 1360
  • [7] System options for cooling of buildings making use of district heating heat
    Chorowski, M.
    Rogala, Z.
    Pyrka, P.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 70 : 183 - 195
  • [8] Impact of PCM type on photocell performance using heat pipe-PCM cooling system: A numerical study
    Gad R.
    Mahmoud H.
    Ookawara S.
    Hassan H.
    Journal of Energy Systems, 2023, 7 (01): : 67 - 88
  • [9] A review on the application of horizontal heat pipe heat exchangers in air conditioning systems in the tropics
    Yau, Y. H.
    Ahmadzadehtalatapeh, M.
    APPLIED THERMAL ENGINEERING, 2010, 30 (2-3) : 77 - 84
  • [10] A study of secondary heat recovery efficiency of a heat pipe heat exchanger air conditioning system
    Wang, Haitao
    Zhou, Shunbao
    Wei, Zhongshi
    Wang, Ren
    ENERGY AND BUILDINGS, 2016, 133 : 206 - 216