Monitoring of Heart and Breathing Rates Using Dual Cameras on a Smartphone

被引:103
|
作者
Nam, Yunyoung [1 ]
Kong, Youngsun [1 ]
Reyes, Bersain [2 ]
Reljin, Natasa [2 ]
Chon, Ki H. [2 ]
机构
[1] Soonchunhyang Univ, Dept Dept Comp Sci & Engn, Asan, South Korea
[2] Univ Connecticut, Dept Biomed Engn, Storrs, CT USA
来源
PLOS ONE | 2016年 / 11卷 / 03期
关键词
RESPIRATORY RATE; PULMONARY-FUNCTION; CARDIAC-SURGERY; MOVEMENTS; PHOTOPLETHYSMOGRAPHY; NONCONTACT; MOTION; WOMEN;
D O I
10.1371/journal.pone.0151013
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Some smartphones have the capability to process video streams from both the front-and rear-facing cameras simultaneously. This paper proposes a new monitoring method for simultaneous estimation of heart and breathing rates using dual cameras of a smartphone. The proposed approach estimates heart rates using a rear-facing camera, while at the same time breathing rates are estimated using a non-contact front-facing camera. For heart rate estimation, a simple application protocol is used to analyze the varying color signals of a fingertip placed in contact with the rear camera. The breathing rate is estimated from non-contact video recordings from both chest and abdominal motions. Reference breathing rates were measured by a respiration belt placed around the chest and abdomen of a subject; reference heart rates (HR) were determined using the standard electrocardiogram. An automated selection of either the chest or abdominal video signal was determined by choosing the signal with a greater autocorrelation value. The breathing rate was then determined by selecting the dominant peak in the power spectrum. To evaluate the performance of the proposed methods, data were collected from 11 healthy subjects. The breathing ranges spanned both low and high frequencies (6-60 breaths/min), and the results show that the average median errors from the reflectance imaging on the chest and the abdominal walls based on choosing the maximum spectral peak were 1.43% and 1.62%, respectively. Similarly, HR estimates were also found to be accurate.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Simplified 3D Hologram Heart Activity Monitoring using a Smartphone
    Thap, Tharoeun
    Nam, Yunyoung
    Chung, Hee-won
    Lee, Jinseok
    2015 9TH INTERNATIONAL CONFERENCE ON INNOVATIVE MOBILE AND INTERNET SERVICES IN UBIQUITOUS COMPUTING IMIS 2015, 2015, : 447 - 451
  • [22] Monitoring of heart rate, blood oxygen saturation, and blood pressure using a smartphone
    Nemcova, Andrea
    Jordanova, Ivana
    Varecka, Martin
    Smisek, Radovan
    Marsanova, Lucie
    Smital, Lukas
    Vitek, Martin
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 59
  • [23] Real-time heart activity monitoring with optical illusion using a smartphone
    Thap, Tharoeun
    Chung, Heewon
    Jeong, Changwon
    Ryu, Jonghyun
    Nam, Yunyoung
    Yoon, Kwon-Ha
    Lee, Jinseok
    MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (05) : 6209 - 6224
  • [24] Real-time heart activity monitoring with optical illusion using a smartphone
    Tharoeun Thap
    Heewon Chung
    Changwon Jeong
    Jonghyun Ryu
    Yunyoung Nam
    Kwon-Ha Yoon
    Jinseok Lee
    Multimedia Tools and Applications, 2018, 77 : 6209 - 6224
  • [25] Application of mobile photography with smartphone cameras for monitoring of orthodontic correction with dental BRACKETS
    Godlevsky LS
    Bidnyuk EA
    Bayazitov NR
    Kresyun NV
    中国现代医学杂志, 2014, 24 (15) : 10 - 14
  • [26] Non-invasive Heart Rate Measuring Smartphone Applications using On-board Cameras: A Short Survey
    Papon, Md Tarikul Islam
    Ahmad, Ishtiyaque
    Saquib, Nazmus
    Rahman, Ashikur
    2015 INTERNATIONAL CONFERENCE ON NETWORKING SYSTEMS AND SECURITY (NSYSS), 2015, : 199 - 204
  • [27] At-Home Pupillometry using Smartphone Facial Identification Cameras
    Barry, Colin
    De Souza, Jessica
    Xuan, Yinan
    Holden, Jason
    Granholm, Eric
    Wang, Edward Jay
    PROCEEDINGS OF THE 2022 CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS (CHI' 22), 2022,
  • [28] MONITORING OF RESPIRATORY AND HEART-RATES USING A FIBEROPTIC SENSOR
    LINDBERG, LG
    UGNELL, H
    OBERG, PA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (05) : 533 - 537
  • [29] Simultaneous Estimation of Instantaneous Heart and Respiratory Rates using Image Photoplethysmography on a Single Smartphone
    Hernandez-de la Cruz, Eduardo
    Charleston-Villalobos, Sonia
    Aljama-Corrales, Tomas
    Reyes, Bersain
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 311 - 314
  • [30] HemaApp: Noninvasive Blood Screening of Hemoglobin using Smartphone Cameras
    Wang, Edward Jay
    Li, William
    Hawkins, Doug
    Gernsheimer, Terry
    Norby-Slycord, Colette
    Patel, Shwetak N.
    UBICOMP'16: PROCEEDINGS OF THE 2016 ACM INTERNATIONAL JOINT CONFERENCE ON PERVASIVE AND UBIQUITOUS COMPUTING, 2016, : 593 - 604