Monitoring of Heart and Breathing Rates Using Dual Cameras on a Smartphone

被引:104
作者
Nam, Yunyoung [1 ]
Kong, Youngsun [1 ]
Reyes, Bersain [2 ]
Reljin, Natasa [2 ]
Chon, Ki H. [2 ]
机构
[1] Soonchunhyang Univ, Dept Dept Comp Sci & Engn, Asan, South Korea
[2] Univ Connecticut, Dept Biomed Engn, Storrs, CT USA
来源
PLOS ONE | 2016年 / 11卷 / 03期
关键词
RESPIRATORY RATE; PULMONARY-FUNCTION; CARDIAC-SURGERY; MOVEMENTS; PHOTOPLETHYSMOGRAPHY; NONCONTACT; MOTION; WOMEN;
D O I
10.1371/journal.pone.0151013
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Some smartphones have the capability to process video streams from both the front-and rear-facing cameras simultaneously. This paper proposes a new monitoring method for simultaneous estimation of heart and breathing rates using dual cameras of a smartphone. The proposed approach estimates heart rates using a rear-facing camera, while at the same time breathing rates are estimated using a non-contact front-facing camera. For heart rate estimation, a simple application protocol is used to analyze the varying color signals of a fingertip placed in contact with the rear camera. The breathing rate is estimated from non-contact video recordings from both chest and abdominal motions. Reference breathing rates were measured by a respiration belt placed around the chest and abdomen of a subject; reference heart rates (HR) were determined using the standard electrocardiogram. An automated selection of either the chest or abdominal video signal was determined by choosing the signal with a greater autocorrelation value. The breathing rate was then determined by selecting the dominant peak in the power spectrum. To evaluate the performance of the proposed methods, data were collected from 11 healthy subjects. The breathing ranges spanned both low and high frequencies (6-60 breaths/min), and the results show that the average median errors from the reflectance imaging on the chest and the abdominal walls based on choosing the maximum spectral peak were 1.43% and 1.62%, respectively. Similarly, HR estimates were also found to be accurate.
引用
收藏
页数:15
相关论文
共 37 条
  • [1] [Anonymous], DR DOBBS J SOFTW TOO
  • [2] Bolkhovsky JB, 2012, IEEE ENG MED BIO, P1610, DOI 10.1109/EMBC.2012.6346253
  • [3] THORACIC KYPHOSIS, RIB MOBILITY, AND LUNG-VOLUMES IN NORMAL WOMEN AND WOMEN WITH OSTEOPOROSIS
    CULHAM, EG
    JIMENEZ, HAI
    KING, CE
    [J]. SPINE, 1994, 19 (11) : 1250 - 1255
  • [4] 3-DIMENSIONAL OPTICAL ANALYSIS OF CHEST-WALL MOTION
    FERRIGNO, G
    CARNEVALI, P
    ALIVERTI, A
    MOLTENI, F
    BEULCKE, G
    PEDOTTI, A
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (03) : 1224 - 1231
  • [5] RESPIRATORY RATE PREDICTS CARDIOPULMONARY ARREST FOR INTERNAL-MEDICINE INPATIENTS
    FIESELMANN, JF
    HENDRYX, MS
    HELMS, CM
    WAKEFIELD, DS
    [J]. JOURNAL OF GENERAL INTERNAL MEDICINE, 1993, 8 (07) : 354 - 360
  • [6] Development and Validation of a Smartphone Heart Rate Acquisition Application for Health Promotion and Wellness Telehealth Applications
    Gregoski, Mathew J.
    Mueller, Martina
    Vertegel, Alexey
    Shaporev, Aleksey
    Jackson, Brenda B.
    Frenzel, Ronja M.
    Sprehn, Sara M.
    Treiber, Frank A.
    [J]. INTERNATIONAL JOURNAL OF TELEMEDICINE AND APPLICATIONS, 2012, 2012
  • [7] Hillman K, 2005, LANCET, V365, P2091
  • [8] Investigating a smartphone imaging unit for photoplethysmography
    Jonathan, E.
    Leahy, Martin
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (11) : N79 - N83
  • [9] Cellular phone-based photoplethysmographic imaging
    Jonathan, Enock
    Leahy, Martin J.
    [J]. JOURNAL OF BIOPHOTONICS, 2011, 4 (05) : 293 - 296
  • [10] Chest wall motion and pulmonary function are more diminished following cardiac surgery when the internal mammary artery retractor is used
    Kristjánsdóttir, A
    Ragnarsdóttir, M
    Hannesson, P
    Beck, HJ
    Torfason, B
    [J]. SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2004, 38 (06) : 369 - 374