Monitoring of Heart and Breathing Rates Using Dual Cameras on a Smartphone

被引:103
|
作者
Nam, Yunyoung [1 ]
Kong, Youngsun [1 ]
Reyes, Bersain [2 ]
Reljin, Natasa [2 ]
Chon, Ki H. [2 ]
机构
[1] Soonchunhyang Univ, Dept Dept Comp Sci & Engn, Asan, South Korea
[2] Univ Connecticut, Dept Biomed Engn, Storrs, CT USA
来源
PLOS ONE | 2016年 / 11卷 / 03期
关键词
RESPIRATORY RATE; PULMONARY-FUNCTION; CARDIAC-SURGERY; MOVEMENTS; PHOTOPLETHYSMOGRAPHY; NONCONTACT; MOTION; WOMEN;
D O I
10.1371/journal.pone.0151013
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Some smartphones have the capability to process video streams from both the front-and rear-facing cameras simultaneously. This paper proposes a new monitoring method for simultaneous estimation of heart and breathing rates using dual cameras of a smartphone. The proposed approach estimates heart rates using a rear-facing camera, while at the same time breathing rates are estimated using a non-contact front-facing camera. For heart rate estimation, a simple application protocol is used to analyze the varying color signals of a fingertip placed in contact with the rear camera. The breathing rate is estimated from non-contact video recordings from both chest and abdominal motions. Reference breathing rates were measured by a respiration belt placed around the chest and abdomen of a subject; reference heart rates (HR) were determined using the standard electrocardiogram. An automated selection of either the chest or abdominal video signal was determined by choosing the signal with a greater autocorrelation value. The breathing rate was then determined by selecting the dominant peak in the power spectrum. To evaluate the performance of the proposed methods, data were collected from 11 healthy subjects. The breathing ranges spanned both low and high frequencies (6-60 breaths/min), and the results show that the average median errors from the reflectance imaging on the chest and the abdominal walls based on choosing the maximum spectral peak were 1.43% and 1.62%, respectively. Similarly, HR estimates were also found to be accurate.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A highly efficient and reliable heart rate monitoring system using smartphone cameras
    Jean-Pierre Lomaliza
    Hanhoon Park
    Multimedia Tools and Applications, 2017, 76 : 21051 - 21071
  • [2] A highly efficient and reliable heart rate monitoring system using smartphone cameras
    Lomaliza, Jean-Pierre
    Park, Hanhoon
    MULTIMEDIA TOOLS AND APPLICATIONS, 2017, 76 (20) : 21051 - 21071
  • [3] Accuracy of the Instantaneous Breathing and Heart Rates Estimated by Smartphone Inertial Units
    Cinotti, Eliana
    Centracchio, Jessica
    Parlato, Salvatore
    Esposito, Daniele
    Fratini, Antonio
    Bifulco, Paolo
    Andreozzi, Emilio
    SENSORS, 2025, 25 (04)
  • [4] Using Rear Smartphone Cameras as Sensors for Measuring Heart Rate Variability
    Zhang, Genxuan
    Zhang, Sai
    Dai, Yiming
    Shi, Bo
    IEEE ACCESS, 2021, 9 (09): : 20460 - 20468
  • [5] Continuous Heart Rate Monitoring using Smartphone
    Turner, Justin
    Zellner, Chase
    Khan, Tareq
    Yelamarthi, Kumar
    2017 IEEE INTERNATIONAL CONFERENCE ON ELECTRO INFORMATION TECHNOLOGY (EIT), 2017, : 324 - 326
  • [6] A Novel Heart Rate Monitoring Method Using a Smartphone
    Zaman, Rifat
    Cho, Chae Ho
    Kim, Yeesock
    Chong, Jo Woon
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 5 - 8
  • [7] Development of Heart Rate Monitoring for Mobile Telemedicine using Smartphone
    Shim, Hun
    Lee, Jung Hoon
    Hwang, Sung Oh
    Yoon, Hyung Ro
    Yoon, Young Ro
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1116 - +
  • [8] Practical use of smartphone cameras in rip current monitoring studies
    Arun Kumar Surisetty, V. V.
    Venkateswarlu, Ch
    Ramesh, M.
    Gireesh, B.
    Naidu, C., V
    Sheela Nair, L.
    Sharma, Rashmi
    OCEAN & COASTAL MANAGEMENT, 2023, 243
  • [9] Measuring Saccade Latency Using Smartphone Cameras
    Lai, Hsin-Yu
    Saavedra-Pena, Gladynel
    Sodini, Charles G.
    Sze, Vivienne
    Heldt, Thomas
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (03) : 885 - 897
  • [10] Smartphone System for Heart Rate and Breathing Rate Estimation
    Nayak, Amit
    Bolic, Miodrag
    IEEE OPEN JOURNAL OF INSTRUMENTATION AND MEASUREMENT, 2024, 3