摘要
Conditions for the formation of a stable and reproducible thin-film mercury microdrop cover on electrodes from carbon glass ceramics, carbon glass, and graphite are proposed. The influence of various factors on the parameters of signals from cadmium (II), lead (II), and copper (II) is studied by stripping voltammetry with linear, differential-pulse, sinusoidal, and square-wave potential sweep. The parameters of the stripping voltammetric experiment are optimized. The value of RSD in determining the specified modeling trace components did not exceed 15%. Approaches to the multicomponent stripping voltammetric analysis of waters are proposed.
引用
收藏
页码:1141 / 1147
页数:7
相关论文
共 50 条
  • [41] Copper film electrode for anodic stripping voltammetric determination of trace mercury and lead
    Jovanovski, V.
    Hrastnik, N. I.
    Hocevar, S. B.
    ELECTROCHEMISTRY COMMUNICATIONS, 2015, 57 : 1 - 4
  • [42] Voltammetric determination of riboflavin based on electrocatalytic oxidation at zeolite-modified carbon paste electrodes
    Nezamzadeh-Ejhieh, Alireza
    Pouladsaz, Pouya
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2014, 20 (04) : 2146 - 2152
  • [43] Simultaneous cathodic stripping voltammetric determination of mercury, cobalt, nickel and palladium by mixed binder carbon paste electrode containing dimethylglyoxime
    Zhang, ZQ
    Liu, H
    Zhang, H
    Li, YF
    ANALYTICA CHIMICA ACTA, 1996, 333 (1-2) : 119 - 124
  • [44] Screen printed electrodes for improvised voltammetric determination of mercury(II) ions
    Kaur K.
    Mittal S.K.
    Ashok Kumar S.K.
    Kumar A.
    Kumar S.
    Metters J.P.
    Banks C.E.
    Mittal, Susheel K. (smittal@thapar.edu), 1600, American Scientific Publishers (14): : 515 - 521
  • [45] Mercury nucleation on glassy carbon electrodes
    Sahlin, E
    Jagner, D
    RatanaOhpas, R
    ANALYTICA CHIMICA ACTA, 1997, 346 (02) : 157 - 164
  • [46] Stripping coulometry determination of lead and mercury at screen-printed electrodes
    Timofeeva, Daria V.
    Tsapko, Yuriy V.
    Ermakov, Sergey S.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) : 195 - 199
  • [47] Copper-mercury film electrode for cathodic stripping voltammetric determination of Se(IV)
    Sladkov, V
    David, F
    Fourest, B
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (02) : 300 - 305
  • [48] A comparative study on carbon paste electrodes modified with hybrid mesoporous materials for voltammetric analysis of lead (II)
    Sanchez, Alfredo
    Morante-Zarcero, Sonia
    Perez-Quintanilla, Damian
    del Hierro, Isabel
    Sierra, Isabel
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 689 : 76 - 82
  • [49] Anodic stripping voltammetric determination of cadmium using a "mercury free" indium film electrode
    Anandhakumar, Sukeri
    Mathiyarasu, Jayaraman
    Phani, Kanala Lakshimi Narasimha
    ANALYST, 2013, 138 (19) : 5674 - 5678
  • [50] Voltammetric analysis of nitroxoline in tablets and human serum using modified carbon paste electrodes incorporating mesoporous carbon or multiwalled carbon nanotubes
    Ghoneim, Mohamed M.
    El-Desoky, Hanaa S.
    Matsuda, Atsunori
    Hattori, Toshiaki
    Abdel-Galeil, Mohamed M.
    RSC ADVANCES, 2015, 5 (69) : 56086 - 56097