Electrochemical cell lysis on a miniaturized flow-through device

被引:16
|
作者
Jha, Sandeep Kumar [1 ]
Ra, Gyu-Sik [1 ]
Joo, Gi-Sung [1 ]
Kim, Yong-Sang [1 ,2 ]
机构
[1] Myongji Univ, Dept Nano Sci & Engn, Gyeonggi 449728, South Korea
[2] Myongji Univ, Dept Elect Engn, Gyeonggi 449728, South Korea
关键词
Cell lysis; Microfluidics; Lab-on-a-chip; PCR;
D O I
10.1016/j.cap.2009.06.035
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A low-cost miniaturized flow-through device was fabricated using conventional photolithographic technique for lysis of whole cells using electrochemically generated hydroxyl groups. The device used low impedance Au-interdigitatedelectrode (IDE) fabricated on glass substrate to input DC potential to the overlaid PDMS based microchannel. The lysis of human cell line MCF-10A could be achieved between 2 and 5 V of DC input with optimum release of genomic DNA at 5 V for 5 min, which is the lowest potential range reported in any such study. The lysate was extracted to confirm release of genomic DNA and was successfully tested for PCR grade purity of DNA by amplifying a known tumor suppressor gene SM Lambda D4. The proposed method was non-destructive for biocomponents due to absence of Joule heating and shall find use in miniaturized PCR analysis as well as where native protein extraction is required under aseptic conditions. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:E301 / E303
页数:3
相关论文
共 50 条
  • [21] Characterization of cell lysis events on a microfluidic device for high-throughput single cell analysis
    Hargis, Amy D.
    Alarie, Jean Pierre
    Ramsey, John Michael
    ELECTROPHORESIS, 2011, 32 (22) : 3172 - 3179
  • [22] Continuous cell cross over and lysis in a microfluidic device
    Byung Phil Mun
    Seung Mo Jung
    Sang Youl Yoon
    So Hee Kim
    Jong Hyun Lee
    Sung Yang
    Microfluidics and Nanofluidics, 2010, 8 : 695 - 701
  • [23] Continuous cell cross over and lysis in a microfluidic device
    Mun, Byung Phil
    Jung, Seung Mo
    Yoon, Sang Youl
    Kim, So Hee
    Lee, Jong Hyun
    Yang, Sung
    MICROFLUIDICS AND NANOFLUIDICS, 2010, 8 (05) : 695 - 701
  • [24] Bioconjugation of peptides using advanced nanomaterials to examine their interactions in 3D printed flow-through device
    Michalek, Petr
    Richtera, Lukas
    Krejcova, Ludmila
    Nejdl, Lukas
    Kensova, Renata
    Zitka, Jan
    Kopel, Pavel
    Heger, Zbynek
    Adam, Vojtech
    Kizek, Rene
    ELECTROPHORESIS, 2016, 37 (03) : 444 - 454
  • [25] Rapid cell stimulus and lysis in segmented flow
    El-Ali, J
    Gaudet, S
    Jensen, KF
    MICRO TOTAL ANALYSIS SYSTEMS 2004, VOL 2, 2005, (297): : 276 - 278
  • [26] Performance Comparison of Flow-Through Optofluidic Biosensor Designs
    Wright, Joel G.
    Amin, Md Nafiz
    Schmidt, Holger
    Hawkins, Aaron R.
    BIOSENSORS-BASEL, 2021, 11 (07):
  • [27] A flow-through potentiometric sensor for an integrated microdialysis system
    Pijanowska, DG
    Sprenkels, A
    van der Linden, H
    Olthuis, W
    Bergveld, P
    van den Berg, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 103 (1-2): : 350 - 355
  • [28] Rapid PCR in flow-through Si chip thermocyclers
    Poser, S
    Ehricht, R
    Schulz, T
    Uebel, S
    Dillner, U
    Köhler, JM
    MICROREACTION TECHNOLOGY: INDUSTRIAL PROSPECTS, 2000, : 410 - 419
  • [29] Comparison of Illumination Methods for Flow-Through Optofluidic Biosensors
    Hamblin, Matthew
    Wright, Joel
    Schmidt, Holger
    Hawkins, Aaron R.
    MICROMACHINES, 2023, 14 (04)
  • [30] Lateral porous silicon interferometric transducer for on-chip flow-through sensing applications
    He, Yingning
    Vasconcellos, Douglas Silva de
    Bourrier, David
    Hajdu, Kata
    Durand, Jean-Olivier
    Cunin, Frederique
    Bardinal, Veronique
    Leichle, Thierry
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 332