Development and validation of a LC-MS/MS method for the enantioseparation and determination of clopidogrel bisulfate in beagle plasma and its application to a stereoselective pharmacokinetic study

被引:0
|
作者
He, Jian [1 ,2 ]
Liu, Wenxia [1 ,2 ]
Zhang, Yu [1 ,2 ]
Zhang, Zunjian [1 ,2 ,3 ]
Tian, Yuan [1 ,2 ]
机构
[1] China Pharmaceut Univ, Key Lab Drug Qual Control & Pharmacovigilance, Minist Educ, 24 Tongjia Lane, Nanjing 210009, Peoples R China
[2] China Pharmaceut Univ, Key Lab Drug Consistency Evaluat, Nanjing 210009, Peoples R China
[3] China Pharmaceut Univ, State Key Lab Nat Med, Nanjing 210009, Peoples R China
关键词
Clopidogrel bisulfate; Enantiomers; LC-MS/MS; Pharmacokinetics; Chiral inversion;
D O I
10.1016/j.jpha.2021.113901
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive chiral liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the enantioseparation and determination of clopidogrel bisulfate enantiomers in beagle plasma was established and successfully applied to a stereoselective pharmacokinetic study. The chromatographic separation was achieved on an Ultron ES-OVM column (150 x 2.0 mm, 5 mu m) with acetonitrileammonium acetate (10 mM, pH 4.5) (22:78, v/v) at a flow rate of 0.3 mL/min. The mass detection was conducted using multiple reaction monitoring mode with the transition of the m/z 322.00 -> 212.00 for clopidogrel and m/z 285.00 -> 193.00 for diazepam (IS), respectively. The calibration curve was linear at the range of 1-800 ng/mL (r(2)>0.997) for each enantiomer. The intra- and inter-day precision (CV%) was within 10.9 % and the accuracy was at the range of 88.5 %-101.3 % for both enantiomers. The extraction recovery was >90.2 % and no obvious matrix effect was observed. The pharmacokinetic results showed that the R-CB have higher Cmax and AUC than that of S-CB. It is first time to find the chiral inversion between S-CB and R-CB in beagle. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Development and validation of an LC-MS/MS method for the determination of mesalazine in beagle dog plasma and its application to a pharmacokinetic study
    Qin, Juan
    Di, Xin
    Wang, Xin
    Liu, Youping
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (02) : 261 - 267
  • [2] Development and validation of an LC-MS/MS method for the determination of tolvaptan in human plasma and its application to a pharmacokinetic study
    Pei, Qi
    Zhang, Bikui
    Tan, Hongyi
    Liu, Lihua
    Peng, Xiangdong
    Li, Zuojun
    Huang, Panhao
    Luo, Mi
    Zuo, Xiaocong
    Guo, Chengxian
    Yang, Guoping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 913 : 84 - 89
  • [3] Validated LC-MS/MS method for the determination of amlodipine enantiomers in rat plasma and its application to a stereoselective pharmacokinetic study
    Wang, Lijuan
    Liu, Wenxia
    Zhang, Zunjian
    Tian, Yuan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 158 : 74 - 81
  • [4] Development and validation of an LC-MS/ MS method for the determination of hinokiflavone in rat plasma and its application to a pharmacokinetic study
    Yin, Ruofeng
    Xiong, Kun
    Wen, Simin
    Wang, Yuanyi
    Xu, Feng
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (03)
  • [5] Development and validation of an LC-MS/MS method for the determination of tofogliflozin in plasma and its application to a pharmacokinetic study in rats
    Kobuchi, Shinji
    Matsuno, Megumi
    Fukuda, Etsuko
    Ito, Yukako
    Sakaeda, Toshiyuki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1027 : 227 - 233
  • [6] Development and validation of an LC-MS/MS method for the determination of bullatine A in rat plasma: application to a pharmacokinetic study
    Teng, Shi-Yong
    Zhang, Si-Xi
    Niu, Kai
    Zhai, Li-Jie
    Wang, Shi-Ji
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (12) : 1798 - 1804
  • [7] Development and Validation of an LC-MS/MS Method for Determination of Tigecycline and Its Epimer in Human Plasma and Its Application in a Pharmacokinetic Study
    Wang, Longyuan
    Hu, Xiaoxiao
    Zhu, Hong
    Zhang, Xiaotian
    Wang, Chuan
    Han, Zhiwu
    ACTA CHROMATOGRAPHICA, 2016, 28 (02) : 239 - 253
  • [8] Development and validation of an LC-MS/MS method for the determination of DPHB in rat plasma and its application in pharmacokinetic studies
    Wen, Qi
    Li, Hai-Long
    Chen, Feng
    Gong, Jing-Wen
    Guan, Wei-Wei
    Fu, Nai-Guang
    Tan, Yin-Feng
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (12)
  • [9] Development and validation of a rapid LC-MS/MS method for simultaneous determination of netupitant and palonosetron in human plasma and its application to a pharmacokinetic study
    Xu, Mingzhen
    Ni, Yang
    Li, Shihong
    Du, Juan
    Li, Huqun
    Zhou, Ying
    Li, Weiyong
    Chen, Hui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1027 : 187 - 193
  • [10] Development and validation of an LC-MS/MS method for the determination of AZD7648 in rat plasma: Application to a pharmacokinetic study
    Fang, Xun
    Lu, Qi
    Han, Jichun
    BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (01)