Comparing test requirements for low-voltage circuit breakers

被引:2
|
作者
Kimblin, CW [1 ]
Long, RW [1 ]
机构
[1] Cutler Hammer, Pittsburgh, PA USA
关键词
Electric switchgear - Equipment testing - Industrial applications - Overcurrent protection - Short circuit currents - Standards;
D O I
10.1109/2943.811078
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The standards dealing with low-voltage power circuit breakers and molded case circuit breakers, have many common elements. As a consequence, either type of circuit breaker could be used for some applications. However, there are several significant performance differences that relate to the application of these circuit breakers, specifically, the low-voltage power circuit breaker is normally applied upstream of the molded case circuit breakers. That location frequently requires higher continuous currents, higher interruption ratings and a short-time current duty cycle capability for selective coordination.
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [21] TRANSIENT RECOVERY VOLTAGE IN SHORT-CIRCUIT TESTS ON LOW-VOLTAGE CIRCUIT-BREAKERS
    BOTTAUSCIO, O
    CROTTI, G
    FARINA, G
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER ENGINEERING, 1991, 1 (05): : 267 - 270
  • [22] Service-life evaluations of low-voltage power circuit breakers and molded-case circuit breakers
    Sprague, MJ
    TAPPI 99 PROCEEDINGS - PREPARING FOR THE NEXT MILLENNIUM, VOLS 1-3: 1999 TAPPI PAPERMAKERS CONFERENCE: SESSIONS 1-8; 1999 TAPPI RECYCLING SYMPOSIUM: SESSIONS 1-6; 1999 TAPPI PROCESS CONTROL, ELECTRICAL AND INFORMATION CONFERENCE 1-9, 1999, : 1405 - 1423
  • [23] Service-life evaluations of low-voltage power circuit breakers and molded-case circuit breakers
    Sprague, MJ
    CONFERENCE RECORD OF 2000 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 2000, : 156 - 164
  • [24] BEHAVIOR OF SWITCHING ARC IN LOW-VOLTAGE LIMITER-CIRCUIT BREAKERS
    BELBEL, EM
    LAURAIRE, M
    IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1985, 8 (01): : 3 - 12
  • [25] Arc flash calculations in systems protected by low-voltage circuit breakers
    Gregory, GD
    Lyttle, I
    Wellman, CM
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (04) : 1193 - 1199
  • [26] Experimental and numerical studies of arc restrikes in low-voltage circuit breakers
    Fievet, C
    Barrault, M
    Chevrier, P
    Petit, P
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1997, 25 (05) : 954 - 960
  • [27] APPLICATION OF NUMERICAL FIELD SIMULATIONS FOR LOW-VOLTAGE CIRCUIT-BREAKERS
    LINDMAYER, M
    STAMMBERGER, H
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART A, 1995, 18 (03): : 708 - 717
  • [28] PROTECTION OF LOW-VOLTAGE NETWORKS, USING AUTOMATIC CIRCUIT-BREAKERS
    ANELLI, R
    CAMPARADA, B
    ELETTROTECNICA, 1988, 75 (04): : 343 - 351
  • [29] Arc flash energy limitations using low-voltage circuit breakers
    Gregory, GD
    Lyttle, I
    Wellman, CM
    INDUSTRY APPLICATIONS SOCIETY 49TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2002, : 291 - 299
  • [30] Review of technologies for current-limiting low-voltage circuit breakers
    Brice, CW
    Dougal, RA
    Hudgins, JL
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (05) : 1005 - 1010