3D/4D spatiotemporal image correlation (STIC) fetal echocardiography provides incremental benefit over 2D fetal echocardiography in predicting postnatal surgical approach in double-outlet right ventricle

被引:16
作者
Karmegaraj, B. [1 ]
Kumar, S. [1 ]
Srimurugan, B. [2 ]
Sudhakar, A. [1 ]
Simpson, J. M. [3 ]
Vaidyanathan, B. [1 ]
机构
[1] Amrita Inst Med Sci & Res Ctr, Dept Paediat Cardiol, Fetal Cardiol Div, Kochi, Kerala, India
[2] Amrita Inst Med Sci & Res Ctr, Dept Cardiovasc Surg, Kochi, Kerala, India
[3] Guys & St Thomas NHS Fdn Trust, Dept Congenital Heart Dis, Evelina London Childrens Hosp, London, England
关键词
3D/4D fetal echocardiography; DORV; double-outlet right ventricle; STIC;
D O I
10.1002/uog.21988
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To analyze the incremental benefit of 3D/4D spatiotemporal image correlation (STIC) fetal echocardiography over 2D fetal echocardiography with respect to the accuracy of identification of anatomic details crucial for surgical decision-making and in predicting surgical approach in fetuses with double-outlet right ventricle (DORV). Methods This was a retrospective study of fetuses with DORV which had undergone both 2D echocardiography and 3D/4D STIC echocardiography andwhich underwent surgery postnatally in a tertiary pediatric cardiac center in Kerala between October 2015 and March 2019. All such cases with normal atrial arrangement, concordant atrioventricular connections and balanced ventricles were included. 2D and 3D/4D STIC fetal echocardiographic data were analyzed by two experienced observers blinded to the other dataset. Anatomic variables crucial for surgical decision-making, i.e. location and routability of the ventricular septal defect, relationship of the great arteries and presence of outflow obstruction, were compared between the two modalities with respect to agreement with postnatal echocardiography. The accuracy of prenatal prediction of the surgical pathway was compared between 2D and 3D/4D modalities with respect to the procedure undertaken. Results Included in the study were 22 fetuses with DORV which had undergone both 2D and 3D/4D imaging as well as postnatal surgery. Accuracy of prenatal interpretation of all four anatomic variables was significantly higher using 3D/4D STIC than using 2D fetal echocardiography (19/22 (86.4%) vs 8/22 (36.4%), P<0.001). Surgical procedures included single-stage repair in 14 (63.5%) patients and amultistage approach in eight (36.4%). Prenatal prediction of the surgical pathway was significantly more accurate on 3D/4D STIC than on 2D echocardiography (20/22 (90.9%) vs 12/22 (54.5%), P=0.021). Prenatal predictive accuracy of single-stage biventricular repair was significantly better for 3D/4D STIC than for 2D echocardiography (14/14 (100%) vs 8/14 (57.1%), P=0.04). Conclusion Addition of 3D/4D STIC to conventional 2D fetal echocardiography confers incremental benefit on the accuracy of identification of anatomic details crucial for surgical decision-making and the prediction of postnatal surgical approach in fetuses with DORV, thereby potentially aiding prenatal counseling. (C) 2020 International Society of Ultrasound in Obstetrics and Gynecology.
引用
收藏
页码:423 / 430
页数:8
相关论文
共 27 条
  • [11] ISUOG consensus statement: what constitutes a fetal echocardiogram?
    Lee, W.
    Allan, L.
    Carvalho, J. S.
    Chaoui, R.
    Copel, J.
    Devore, G.
    Hecher, K.
    Munoz, H.
    Nelson, T.
    Paladini, D.
    Yagel, S.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (02) : 239 - 242
  • [12] Biventricular repair for double outlet right ventricle with non-committed ventricular septal defect
    Li, Shoujun
    Ma, Kai
    Hu, Shengshou
    Hua, Zhongdong
    Yan, Jun
    Pang, Kunjing
    Wang, Xu
    Yan, Fuxia
    Liu, Jinping
    Zhang, Sen
    Chen, Qiuming
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 48 (04) : 580 - 587
  • [13] Losay J, 2001, CIRCULATION, V104, pI121
  • [14] Anatomy, echocardiography, and surgical approach to double outlet right ventricle
    Mahle, William T.
    Martinez, Richard
    Silverman, Norman
    Cohen, Meryl S.
    Anderson, Robert H.
    [J]. CARDIOLOGY IN THE YOUNG, 2008, 18 : 39 - 51
  • [15] CONGENITAL HEART DISEASE IN 56,109 BIRTHS - INCIDENCE AND NATURAL HISTORY
    MITCHELL, SC
    KORONES, SB
    BERENDES, HW
    [J]. CIRCULATION, 1971, 43 (03) : 323 - &
  • [16] The role of spatio-temporal image correlation (STIC) with tomographic ultrasound imaging (TUI) in the sequential analysis of fetal congenital heart disease
    Paladini, D.
    Vassallo, M.
    Sglavo, G.
    Lapadula, C.
    Martinelli, P.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (05) : 555 - 561
  • [17] A Systematic Three-Dimensional Echocardiographic Approach to Assist Surgical Planning in Double Outlet Right Ventricle
    Pushparajah, Kuberan
    Barlow, Anna
    Vi-Hue Tran
    Miller, Owen I.
    Zidere, Vita
    Vaidyanathan, Balu
    Simpson, John M.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (02): : 234 - 238
  • [18] Impact of fetal echocardiography
    Simpson, John M.
    [J]. ANNALS OF PEDIATRIC CARDIOLOGY, 2009, 2 (01) : 41 - 50
  • [19] Prenatal screening for congenital heart disease using real-time three-dimensional echocardiography and a novel "sweep volume' acquisition technique
    Sklansky, M
    Miller, D
    Devore, G
    Kung, G
    Pretorius, D
    Wong, P
    Chang, RK
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (05) : 435 - 443
  • [20] A systematic analysis of the feasibility of four-dimensional ultrasound imaging using spatiotemporal image correlation in routine fetal echocardiography
    Uittenbogaard, L. B.
    Haak, M. C.
    Spreeuwenberg, M. D.
    Van Vugt, J. M. G.