Study on the Imaging Resolution of a Multiply-stacked Compton Camera

被引:1
作者
Kim, N. Y. [1 ]
Lee, J. H. [1 ]
Lee, C. S. [1 ]
机构
[1] Chung Ang Univ, Dept Phys, Seoul 156756, South Korea
关键词
Compton camera; Double-sided silicon strip detector; GEANT4; Compton scattering; Image resolution; GAMMA-CAMERA; PERFORMANCE; TELESCOPE;
D O I
10.3938/jkps.55.1409
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We have investigated the effect of detector parameters, such as the energy and the position resolution, on the imaging resolution and sensitivity of a multiply-stacked Compton camera by using the proof-of-principle system and the GEANT4 simulation toolkit, including Doppler broadening. The multiply-stacked Compton camera consisted of three double-sided silicon strip detectors. The proof-of-principle system shows that the three-Compton method can reconstruct the incident gamma-ray energy distributions and that it helps to illustrate the usefulness of the three-Compton method when gamma rays don't stop completely. Reconstructed images and spectra from a Cs-137 gamma-ray source have been obtained by using an event reconstruction algorithm. The reconstructed gamma-ray energy shows a photopeak of 661.7 keV for Cs-137 at 607.5 keV and has a 149.8-keV FWHM. GEANT4 simulation results show the feasibility of using the proof-of-principle system in the energy range from 661.7 keV to 1400.0 keV. The image resolution was significantly affected by the position resolution of the multiply-stacked Compton camera rather than by the energy resolution of the detector.
引用
收藏
页码:1409 / 1415
页数:7
相关论文
共 50 条
  • [21] Design Study of a Compton Camera for Prompt γ Imaging During Ion Beam Therapy
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4172 - +
  • [22] Bin mode estimation methods for Compton camera imaging
    Ikeda, S.
    Odaka, H.
    Uemura, M.
    Takahashi, T.
    Watanabe, S.
    Takeda, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 760 : 46 - 56
  • [23] Compton camera imaging and the cone transform: a brief overview
    Terzioglu, Fatma
    Kuchment, Peter
    Kunyansky, Leonid
    INVERSE PROBLEMS, 2018, 34 (05)
  • [24] CCMod: a GATE module for Compton camera imaging simulation
    Etxebeste, A.
    Dauvergne, D.
    Fontana, M.
    Letang, J. M.
    Llosa, G.
    Munoz, E.
    Oliver, J. F.
    Testa, E.
    Sarrut, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05)
  • [25] Silicon detector for a Compton camera in nuclear medical imaging
    Meier, D
    Czermak, A
    Jalocha, P
    Sowicki, B
    Kowal, M
    Dulinski, W
    Mæhlum, G
    Nygård, E
    Yoshioka, K
    Fuster, J
    Lacasta, C
    Mikuz, M
    Roe, S
    Weilhammer, P
    Hua, CH
    Park, SJ
    Wildermann, SJ
    Zhang, L
    Clinthorne, NH
    Rogers, WL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 812 - 816
  • [26] Monte-Carlo Study on the Characterization of CsI Scintillator for a CsI Based Compton Camera
    Malik, Azhar H.
    2015 13TH INTERNATIONAL CONFERENCE ON FRONTIERS OF INFORMATION TECHNOLOGY (FIT), 2015, : 109 - 113
  • [27] Noise evaluation of Compton camera imaging for proton therapy
    Ortega, P. G.
    Torres-Espallardo, I.
    Cerutti, F.
    Ferrari, A.
    Gillam, J. E.
    Lacasta, C.
    Llosa, G.
    Oliver, J. F.
    Sala, P. R.
    Solevi, P.
    Rafecas, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05) : 1845 - 1863
  • [28] Uncertainty analysis of a Compton camera imaging system for radiation therapy dose reconstruction
    Mundy, Daniel W.
    Herman, Michael G.
    MEDICAL PHYSICS, 2010, 37 (05) : 2341 - 2350
  • [29] Monte Carlo study on the Imaging resolution and sensitivity of a Comoton camera
    Lee, J. H.
    Lee, C. S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2006, 49 (01) : 97 - 102
  • [30] An Electron-Tracking Compton imaging Camera based on a gaseous TPC and a scintillation camera
    Ueno, K.
    Hattori, K.
    Kabuki, S.
    Kubo, H.
    Kurosawa, S.
    Miuchi, K.
    Nagayoshi, T.
    Nishimura, H.
    Okada, Y.
    Orito, R.
    Takada, A.
    Tanimori, T.
    Tsuchiya, K.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1960 - +