Comparison of shape-matching and docking as virtual screening tools

被引:744
作者
Hawkins, Paul C. D. [1 ]
Skillman, A. Geoffrey [1 ]
Nicholls, Anthony [1 ]
机构
[1] OpenEye Sci Software, Santa Fe, NM 87507 USA
关键词
D O I
10.1021/jm0603365
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Ligand docking is a widely used approach in virtual screening. In recent years a large number of publications have appeared in which docking tools are compared and evaluated for their effectiveness in virtual screening against a wide variety of protein targets. These studies have shown that the effectiveness of docking in virtual screening is highly variable due to a large number of possible confounding factors. Another class of method that has shown promise in virtual screening is the shape-based, ligand-centric approach. Several direct comparisons of docking with the shape-based tool ROCS have been conducted using data sets from some of these recent docking publications. The results show that a shape-based, ligand-centric approach is more consistent than, and often superior to, the protein-centric approach taken by docking.
引用
收藏
页码:74 / 82
页数:9
相关论文
共 44 条
  • [1] Efficient generation, storage, and manipulation of fully flexible pharmacophore multiplets and their use in 3-D similarity searching
    Abrahamian, E
    Fox, PC
    Nærum, L
    Christensen, IT
    Thogersen, H
    Clark, RD
    [J]. JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 2003, 43 (02): : 458 - 468
  • [2] Virtual screening and scaffold hopping based on GRID molecular interaction fields
    Ahlström, MM
    Ridderström, M
    Luthman, K
    Zamora, I
    [J]. JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2005, 45 (05) : 1313 - 1323
  • [3] Assessing the accuracy of prediction algorithms for classification: an overview
    Baldi, P
    Brunak, S
    Chauvin, Y
    Andersen, CAF
    Nielsen, H
    [J]. BIOINFORMATICS, 2000, 16 (05) : 412 - 424
  • [4] BERMAN HM, 2000, NUCLEIC ACIDS RES, V28, P325
  • [5] Protein-based virtual screening of chemical databases. 1. Evaluation of different docking/scoring combinations
    Bissantz, C
    Folkers, G
    Rognan, D
    [J]. JOURNAL OF MEDICINAL CHEMISTRY, 2000, 43 (25) : 4759 - 4767
  • [6] Assessing the performance of OMEGA with respect to retrieving bioactive conformations
    Boström, J
    Greenwood, JR
    Gottfries, J
    [J]. JOURNAL OF MOLECULAR GRAPHICS & MODELLING, 2003, 21 (05) : 449 - 462
  • [7] Comparing protein-ligand docking programs is difficult
    Cole, JC
    Murray, CW
    Nissink, JWM
    Taylor, RD
    Taylor, R
    [J]. PROTEINS-STRUCTURE FUNCTION AND BIOINFORMATICS, 2005, 60 (03) : 325 - 332
  • [8] Comparison of automated docking programs as virtual screening tools
    Cummings, MD
    DesJarlais, RL
    Gibbs, AC
    Mohan, V
    Jaeger, EP
    [J]. JOURNAL OF MEDICINAL CHEMISTRY, 2005, 48 (04) : 962 - 976
  • [9] Molecular docking and high-throughput screening for novel inhibitors of protein tyrosine phosphatase-1B
    Doman, TN
    McGovern, SL
    Witherbee, BJ
    Kasten, TP
    Kurumbail, R
    Stallings, WC
    Connolly, DT
    Shoichet, BK
    [J]. JOURNAL OF MEDICINAL CHEMISTRY, 2002, 45 (11) : 2213 - 2221
  • [10] Lessons in molecular recognition: The effects of ligand and protein flexibility on molecular docking accuracy
    Erickson, JA
    Jalaie, M
    Robertson, DH
    Lewis, RA
    Vieth, M
    [J]. JOURNAL OF MEDICINAL CHEMISTRY, 2004, 47 (01) : 45 - 55