Cross calibration of IRS-P4 OCM satellite sensor

被引:2
|
作者
Suresh, T. [1 ]
Desa, Elgar [1 ]
Mascarenhas, Antonio [1 ]
Matondkar, S. G. Prabhu [1 ]
Naik, Puneeta [1 ]
Nayak, S. R. [2 ]
机构
[1] Natl Inst Oceanog, Panaji 403004, Goa, India
[2] Ctr Space Applicat, Ahmadabad, Gujarat, India
来源
REMOTE SENSING AND MODELING OF THE ATMOSPHERE, OCEANS, AND INTERACTIONS | 2006年 / 6404卷
关键词
OCM; IRS-P4; cross-calibration; vicarious calibration; 6S; SeaWiFS;
D O I
10.1117/12.694019
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
We present here the cross calibration of ocean color satellite sensor, IRS-P4 OCM using the radiative transfer code, with SeaWiFS as a reference. Since the bands of IRS-P4 OCM are identical to those of SeaWiFS and SeaWiFS has been continuously and rigorously calibrated, SeaWiFS is used as a reference for the cross calibration of IRS-P4 OCM. Calibrations coefficients for each band of IRS-P4 OCM are derived by comparing the actual radiances detected by the satellites at top of the atmosphere and those obtained from the radiative transfer simulations of IRS-P4 OCM and SeaWiFS. The chlorophyll a values derived using the calibrated IRS-P4 OCM are found to be comparable with those derived from SeaWiFS and in close agreement with the measured values. The relative root mean square error (RRMSE) between measured chlorophyll a and those derived from the satellites are found to be 0.28 and 0.26 for SeaWiFS and IRS-P4 OCM respectively.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Online resource for Earth-observing satellite sensor calibration
    McCorkel, J.
    Czapla-Myers, J.
    Thome, K.
    Wenny, B.
    EARTH OBSERVING SYSTEMS XX, 2015, 9607
  • [23] Simulation of TOA Visible Radiance for the Ocean Target and its Possible use for Satellite Sensor Calibration
    Kim, Jungun
    Sohn, Byung-Ju
    Chung, Eui-Seok
    Chun, Hyoung-Wook
    Suh, Ae-Sook
    Kim, Kum-Lan
    Oh, Milim
    KOREAN JOURNAL OF REMOTE SENSING, 2008, 24 (06) : 535 - 549
  • [24] Extended Pseudo Invariant Calibration Site-Based Trend-to-Trend Cross-Calibration of Optical Satellite Sensors
    Khakurel, Prathana
    Leigh, Larry
    Kaewmanee, Morakot
    Pinto, Cibele Teixeira
    REMOTE SENSING, 2021, 13 (08)
  • [25] Extended Pseudo Invariant Calibration Sites (EPICS) for the Cross-Calibration of Optical Satellite Sensors
    Shrestha, Mahesh
    Hasan, Md. Nahid
    Leigh, Larry
    Helder, Dennis
    REMOTE SENSING, 2019, 11 (14)
  • [26] Concept of a Satellite Cross-Calibration Radiometer for In-Orbit Calibration of Commercial Optical Satellites
    Thankappan, Medhavy
    Christopherson, Jon
    Cantrell, Simon
    Ryan, Robert
    Pagnutti, Mary
    Bright, Courtney
    Naughton, Denis
    Ruslander, Kathryn
    Wang, Lan-Wei
    Hudson, David
    Shaw, Jerad
    Ramaseri Chandra, Shankar Nag
    Anderson, Cody
    REMOTE SENSING, 2024, 16 (08)
  • [27] Cross calibration of GF-4 visible and near-infrared sensor with CE-3 VNIS sensor based on lunar
    Tan, Wei
    Qi, Wenwen
    Wu, Yunzhao
    He, Hongyan
    Cao, Shixiang
    OPTIK, 2020, 210
  • [28] Cross calibration of GF-1 satellite wide field of view sensor with Landsat 8 OLI and HJ-1A HSI
    Liu, Li
    Gao, Hailiang
    Pan, Zhiqiang
    Gu, Xingfa
    Han, Qijin
    Zhang, Xuewen
    JOURNAL OF APPLIED REMOTE SENSING, 2018, 12
  • [29] Vicarious Cross-Calibration of the China Environment Satellite Using Nearly Simultaneously Observations of Landsat-7 ETM+ Sensor
    Wenting Quan
    Journal of the Indian Society of Remote Sensing, 2014, 42 : 539 - 548
  • [30] Vicarious Cross-Calibration of the China Environment Satellite Using Nearly Simultaneously Observations of Landsat-7 ETM+ Sensor
    Quan, Wenting
    JOURNAL OF THE INDIAN SOCIETY OF REMOTE SENSING, 2014, 42 (03) : 539 - 548