摘要
Background: The residual uraemic syndrome that is inadequately cleared by diffusion is thought to contribute to the poor outcome of maintenance dialysis patients. Haemodiafiltration combines diffusion and convection in a single therapy, conferring theoretical benefits over haemodialysis. However, only few randomised comparisons have been carried out. Methods: The prospective crossover clinical evaluation of high-flux ultrapure haemodialysis and online haemodiafiltration included 76 clinically stable patients on low-flux conventional bicarbonate buffered haemodialysis. They were randomized to high-flux haemodialysis or online haemodiafiltration (24 months) and switched to the alternative treatment (24 months). Results: Removal of urea (Kt/N and phosphate was signicantly greater for online haernodlafiltration than for haernodialysis. Both high-flux haemodiaINTSis and haemodiafiltration were associated with sustained reductions of pretreatment beta 2 microglobulin levels, however, the decrease was greater with haemodiafiltration. Both modes of renal replacement therapy significantly improved nutritional status and the haematopoietic response to rHu EPO. Under unmatched conditions (sodium and energy balance) haemodiafiltration was associated with a lower number of hypotensive episodes and partial improvement of quality of life. The incidence of death was low in both groups and did not differ among the two modes of renal replacement therapy. Conclusion: Online haernodiafiltration is a safe, effective and well tolerated therapy for end-stage renal disease patients even in the long run. Whether the dismal mortality rates of unsclccted end-stage renal disease patients can be changed bv online haemodiafiltration remains to be shown in large scale long-term trials.
引用
收藏
页码:26 / 33
页数:8
相关论文
共 22 条
[1]   USING ULTRAPURE WATER IN HEMODIALYSIS DELAYS CARPAL-TUNNEL SYNDROME [J].
BAZ, M ;
DURAND, C ;
RAGON, A ;
JABER, K ;
ANDRIEU, D ;
MERZOUK, T ;
PURGUS, R ;
OLMER, M ;
REYNIER, JP ;
BERLAND, Y .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (11) :681-685
[2]   Mortality risk for patients receiving hemodiafiltration versus hemodialysis: European results from the DOPPS [J].
Canaud, B. ;
Bragg-Gresham, J. L. ;
Marshall, M. R. ;
Desmeules, S. ;
Gillespie, B. W. ;
Depner, T. ;
Klassen, P. ;
Port, F. K. .
KIDNEY INTERNATIONAL, 2006, 69 (11) :2087-2093
[3]  
Canaud Bernard, 2006, Hemodial Int, V10 Suppl 1, pS5, DOI 10.1111/j.1542-4758.2006.01183.x
[4]   Serum β-2 microglobulin levels predict mortality in dialysis patients:: Results of the HEMO study [J].
Cheung, Alfred K. ;
Rocco, Michael V. ;
Yan, Guofen ;
Leypoldt, John K. ;
Levin, Nathan W. ;
Greene, Tom ;
Agodoa, Lawrence ;
Bailey, James ;
Beck, Gerald J. ;
Clark, William ;
Levey, Andrew S. ;
Ornt, Daniel B. ;
Schulman, Gerald ;
Schwab, Steven ;
Teehan, Brendan ;
Eknoyan, Garabed .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 17 (02) :546-555
[5]   Reduction of hypotensive side effects during online-haemodiafiltration and low temperature haemodialysis [J].
Donauer, J ;
Schweiger, C ;
Rumberger, B ;
Krumme, B ;
Böhler, J .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2003, 18 (08) :1616-1622
[6]   Effect of dialysis dose and membrane flux in maintenance hemodialysis. [J].
Eknoyan, G ;
Beck, GJ ;
Cheung, AK ;
Daugirdas, JT ;
Greene, T ;
Kusek, JW ;
Allon, M ;
Bailey, J ;
Delmez, JA ;
Depner, TA ;
Dwyer, JT ;
Levey, AS ;
Levin, NW ;
Milford, E ;
Ornt, DB ;
Rocco, MV ;
Schulman, G ;
Schwab, SJ ;
Teehan, BP ;
Toto, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (25) :2010-2019
[7]  
Hsu PY, 2004, J NEPHROL, V17, P693
[8]   High-flux hemodialysis postpones clinical manifestation of dialysis-related amyloidosis [J].
Kiichle, C ;
Fricke, H ;
Held, E ;
Schiffl, H .
AMERICAN JOURNAL OF NEPHROLOGY, 1996, 16 (06) :484-488
[9]   Switch from conventional to high-flux membrane reduces the risk of carpal tunnel syndrome and mortality of hemodialysis patients [J].
Koda, Y ;
Nishi, S ;
Miyazaki, S ;
Haginoshita, S ;
Sakurabayashi, T ;
Suzuki, M ;
Sakai, S ;
Yuasa, Y ;
Hirasawa, Y ;
Nishi, T .
KIDNEY INTERNATIONAL, 1997, 52 (04) :1096-1101
[10]   Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters [J].
Locatelli, F ;
Mastrangelo, F ;
Redaelli, B ;
Ronco, C ;
Marcelli, D ;
LaGreca, G ;
Orlandini, G ;
Corti, M ;
Pontoriero, G ;
DiFilippo, S ;
Rossi, R ;
Farma, R ;
Colantonio, P ;
Martinelli, D ;
Vasile, A ;
Allegra, V ;
Mengozzi, G ;
Martinbianco, L ;
Bonomini, V ;
Stefoni, C ;
Coli, L ;
Cianciolo, G ;
DeSanctis, L ;
DeBlasi, V ;
Alfonso, L ;
Rizzelli, S ;
Patruno, P ;
Brendolan, A ;
Crepaldi, C ;
Casu, MD ;
Mureddu, S ;
Maiorca, R ;
Cristinelli, L ;
Setti, G ;
Camerini, C ;
Salvadori, M ;
Bandini, S ;
Rosati, A ;
Mancini, G ;
Panzetta, G ;
Ianche, M ;
DelMastro, G ;
Cogoni, G ;
Accalai, GP ;
Sechi, MA ;
Alloatti, S ;
Paternoster, G ;
Gaiter, A ;
Manes, M ;
Schena, FP .
KIDNEY INTERNATIONAL, 1996, 50 (04) :1293-1302