Comparative study of compressive and fatigue strength of dental implants made of nanocrystalline Ti Hard and microcrystalline Ti G4

被引:9
作者
Elias, C. N. [1 ]
Fernandes, D. J. [1 ]
de Biasi, R. S. [1 ]
机构
[1] Inst Mil Engn, Lab Biomat, BR-22290270 Rio De Janeiro, RJ, Brazil
关键词
dental implants; ECAP titanium; fatigue implant; implant failure; nanocrystalline titanium; ABUTMENT CONNECTIONS; TITANIUM; BEHAVIOR;
D O I
10.1111/ffe.12538
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Over the last decades, much research has been done to improve the surface quality of dental implants, but there was no change in the materials used to manufacture the implants. The purpose of the present work is to compare the compressive strength and fatigue failure of dental implants made with a new material, nanocrystalline Ti grade 4 fabricated by Equal Channel Angular Pressing (ECAP) (Ti Hard) with a traditional material, microcrystalline Ti grade 4 (Ti G4). Machined screw-shaped implants with three different designs (Easy, Torq and Flash) made with the two materials were subjected to static and dynamic compressive loads. Implants made with Ti Hard showed higher static compressive strength (Easy: 889.9 +/- 79.4 N, Flash: 588.9 +/- 74.7 N, Torq: 498.3 +/- 54.6 N) than implants made with TiG4 (Easy: 776.4 +/- 74.5 N, Flash: 308.8 +/- 15.2 N, Torq: 410.3 +/- 25.2 N) and higher fatigue strength for 5 10(6) cycles (Easy: 400 N, Flash: 280 N, Torq: 260 N) than implants made with TiG4 (Easy: 300 N, Flash: 200 N, Torq: 200 N). The higher fatigue strength of nanocrystalline Ti G4 is attributed to a delay in crack initiation.
引用
收藏
页码:696 / 705
页数:10
相关论文
共 25 条
  • [11] Garbacz H, 2012, TI-2011: PROCEEDINGS OF THE 12TH WORLD CONFERENCE ON TITANIUM, VOL II, P1137
  • [12] Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants
    Gil, F. J.
    Herrero-Climent, M.
    Lazaro, P.
    Rios, J. V.
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (07) : 1825 - 1830
  • [13] International Organization for Standardization ISO 14801:2007, 2007, 148012007 ISO
  • [14] Microstructure-based modeling of the impact response of a biomedical niobium-zirconium alloy
    Onal, Orkun
    Bal, Burak
    Toker, S. Mine
    Mirzajanzadeh, Morad
    Canadinc, Demircan
    Maier, Hans J.
    [J]. JOURNAL OF MATERIALS RESEARCH, 2014, 29 (10) : 1123 - 1134
  • [15] Fatigue characteristics of five types of implant-abutment joint designs
    Park, Il Song
    Won, Sang Yong
    Bae, Tae Sung
    Song, Kwang Yeob
    Park, Charn Woon
    Eom, Tae Gwan
    Jeong, Chang Mo
    [J]. METALS AND MATERIALS INTERNATIONAL, 2008, 14 (02) : 133 - 138
  • [16] Richter E J, 1995, Int J Oral Maxillofac Implants, V10, P99
  • [17] Russo M. A., 1972, THESIS
  • [18] Scanning Electron Microscopy Fractography Analysis of Fractured Hollow Implants
    Sbordone, Ludovico
    Traini, Tonino
    Caputi, Sergio
    Scarano, Antonio
    Bortolaia, Claudia
    Piattelli, Adriano
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (02) : 105 - 112
  • [19] Sequential bone healing of immediately loaded mini-implants: histomorphometric and fluorescence analysis
    Serra, Glaucio
    Morais, Liliane S.
    Elias, Carlos Nelson
    Meyers, Marc A.
    Andrade, Leonardo
    Mueller, Carlos A.
    Mueller, Marcelo
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (01) : 80 - 90
  • [20] On the mechanical integrity of retrieved dental implants
    Shemtov-Yona, K.
    Rittel, D.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2015, 49 : 290 - 299