WOLD decomposition of the backscatter echo in ultrasound images of soft tissue organs

被引:42
作者
Cohen, FS [1 ]
Georgiou, G [1 ]
Halpern, EJ [1 ]
机构
[1] THOMAS JEFFERSON UNIV HOSP,DEPT RADIOL,PHILADELPHIA,PA 19107
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.585131
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper deals with a method of detecting and estimating the scatterer spacing between the regularly spaced resolvable coherent scatterers in tissue. Scatterer spacing has been successfully used in classifying tissue structure, in differentiating between normal and cirrhotic liver, and in detecting diffuse liver disease. This paper presents a WOLD decomposition of the radio frequency (RF) field into its diffused and coherent components from which maximum likelihood estimates (MLE) or minimum mean square error (MMSE) estimates of the scattering spacing are easily computed. The MLE are efficient and for relatively long record are unbiased. They result in accurate estimates in low signal-to-noise (SNR) ratios. Unfortunately, they require nonlinear minimization and knowledge of the probability density associated with the RF backscatter echo. The MMSE estimates, on the other hand, are computationally simple, yield unique closed form solutions, do not require a-priori knowledge of the probability distribution function of the backscatter echo, and result in accurate estimates in low SNR ratios. This paper also presents an unbiased decision rule to detect whether or not an RF echo exhibits any specular scattering relative to the wavelength of the interrogating ultrasonic pulse. The approach has been tried on simulations as well as on in-vivo scans of liver data, and appears to perform well.
引用
收藏
页码:460 / 472
页数:13
相关论文
共 22 条
[1]  
ABEYRATNE UR, 1996, IEEE T MED IMAGING, V14, P479
[2]  
AKAIKE H, 1974, IEEE T AUTOMAT CONTR, V6
[3]  
BOX GEP, 1994, TIME SERIES ANAL
[4]   SPECTRAL CORRELATION IN ULTRASONIC PULSE-ECHO SIGNAL-PROCESSING [J].
DONOHUE, KD ;
BRESSLER, JM ;
VARGHESE, T ;
BILGUTAY, NM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (04) :330-337
[5]  
FELLINGHAM LL, 1984, IEEE T ULTRASON FERR, V13, P418
[6]   QUANTITATIVE ULTRASONIC-DETECTION AND CLASSIFICATION OF DIFFUSE LIVER-DISEASE - COMPARISON WITH HUMAN OBSERVER PERFORMANCE [J].
GARRA, BS ;
INSANA, MF ;
SHAWKER, TH ;
WAGNER, RF ;
BRADFORD, M ;
RUSSELL, M .
INVESTIGATIVE RADIOLOGY, 1989, 24 (03) :196-203
[7]   ANALYSIS OF ULTRASOUND IMAGE TEXTURE VIA GENERALIZED RICIAN STATISTICS [J].
INSANA, MF ;
WAGNER, RF ;
GARRA, BS ;
BROWN, DG ;
SHAWKER, TH .
OPTICAL ENGINEERING, 1986, 25 (06) :743-748
[8]  
Jain AK., 1989, FUNDAMENTALS DIGITAL
[10]  
Kay SM., 1988, Modern spectral estimation: theory and application