North American single-center experience with a sutureless aortic bioprosthesis

被引:7
作者
de Varennes, Benoit [1 ]
Lachapelle, Kevin [1 ]
Cecere, Renzo [1 ]
Szczepkowski, Isabel [1 ]
Buithieu, Jean [2 ]
机构
[1] McGill Univ, Ctr Hlth, Div Cardiac Surg, Montreal, PQ H3A 1A1, Canada
[2] McGill Univ, Ctr Hlth, Div Cardiol, Montreal, PQ H3A 1A1, Canada
关键词
aortic valve; surgery; sutureless; VALVE-REPLACEMENT; CLINICAL-EXPERIENCE; TRANSCATHETER; REGURGITATION; MULTICENTER; OUTCOMES; STENOSIS; IMPACT;
D O I
10.1016/j.jtcvs.2015.10.064
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Surgical sutureless aortic valves have the potential for shorter procedural times and could benefit patients with increased risk. The Enable (Medtronic Inc, Minneapolis, Minn) valve is a bioprosthesis housed in a Nitinol cage allowing folding and deployment once implanted. We aimed to evaluate the early clinical and echocardiographic results with the Enable valve. Methods: Patients with aortic stenosis, Society of Thoracic Surgeons score greater than 5.0%, the need for combined procedures, and frailty were considered for Enable implantation. Results: Between August 2012 and October 2014, 63 patients underwent implantation of the Enable valve (Medtronic Inc, Minneapolis, Minn). Thirty patients underwent isolated aortic valve replacement. Combined procedures were aortic valve replacement/coronary artery bypass grafting (26), aortic valve replacement/mitral valve repair (2), aortic valve replacement/mitral valve repair/coronary artery bypass grafting (2), and aortic valve replacement/ascending aortic graft (3). Predicted Society of Thoracic Surgeons score was 8.06 +/- 7.73 (0.94-41.30). Implant success was 100%. Mean crossclamp time for isolated aortic valve replacement was 44 +/- 14 minutes (30-91). Thirty-day mortality was 1.6% (1/63), and late mortality was 3.2% (2/62). No mortality was valve related. Intraoperative need for revision was 6.3% (4/63). Early migration requiring reoperation occurred in 1.6% of patients (1/63). Postoperative indexed aortic valve area was 1.08 +/- 0.22 cm(2)/m(2), and peak and mean gradients were 17 +/- 7 mm Hg and 9 +/- 4 mm Hg, respectively. The rate of complications was as follows: pacemaker 3.1% (2/63), transient ischemic attack 1.6% (1/63), other thromboembolic events 0%, bleeding 0%, and endocarditis 0%. Mean follow-up was 10 +/- 8 months. At latest follow-up, 61 patients were in New York Heart Association class I. Moderate or severe aortic regurgitation did not develop in any patients in the follow-up period. Conclusions: The Enable bioprosthesis is an acceptable alternative to conventional aortic valve replacement in higher-risk patients. The early hemodynamic performance seems favorable.
引用
收藏
页码:735 / 742
页数:8
相关论文
共 16 条
[1]   Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry [J].
Abdel-Wahab, Mohamed ;
Zahn, Ralf ;
Horack, Martin ;
Gerckens, Ulrich ;
Schuler, Gerhard ;
Sievert, Horst ;
Eggebrecht, Holger ;
Senges, Jochen ;
Richardt, Gert .
HEART, 2011, 97 (11) :899-906
[2]   Clinical experience with the second-generation 3f Enable sutureless aortic valve prosthesis [J].
Aymard, Thierry ;
Kadner, Alexander ;
Walpoth, Nazan ;
Goeber, Volkhart ;
Englberger, Lars ;
Stalder, Mario ;
Eckstein, Friedrich ;
Zobrist, Claudia ;
Carrel, Thierry .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (02) :313-316
[3]   Early single-center experience in sutureless aortic valve implantation in 120 patients [J].
Eichstaedt, Harald C. ;
Easo, Jerry ;
Haerle, Tobias ;
Dapunt, Otto E. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (01) :370-375
[4]   Clinical performance of a sutureless aortic bioprosthesis: Five-year results of the 3f Enable long-term follow-up study [J].
Englberger, Lars ;
Carrel, Thierry P. ;
Doss, Mirko ;
Sadowski, Jerzy ;
Bartus, Krzysztof ;
Eckstein, Friedrich F. ;
Asch, Federico M. ;
Martens, Sven .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (04) :1681-1687
[5]   Paravalvular Leak After Transcatheter Aortic Valve Replacement The New Achilles' Heel? A Comprehensive Review of the Literature [J].
Genereux, Philippe ;
Head, Stuart J. ;
Hahn, Rebecca ;
Daneault, Benoit ;
Kodali, Susheel ;
Williams, Mathew R. ;
van Mieghem, Nicolas M. ;
Alu, Maria C. ;
Serruys, Patrick W. ;
Kappetein, A. Pieter ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (11) :1125-1136
[6]   One-year outcomes of the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial: A prospective multicenter study of rapid-deployment aortic valve replacement with the EDWARDS INTUITY Valve System [J].
Kocher, Alfred A. ;
Laufer, Guenther ;
Haverich, Axel ;
Shrestha, Malakh ;
Walther, Thomas ;
Misfeld, Martin ;
Kempfert, Joerg ;
Gillam, Linda ;
Schmitz, Christoph ;
Wahlers, Thorsten C. ;
Wippermann, Jens ;
Mohr, Friedrich W. ;
Roth, Matthias ;
Skwara, Adalbert ;
Rahmanian, Parwis ;
Wiedemann, Dominik ;
Borger, Michael A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (01) :110-116
[7]   Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement [J].
Kodali, Susheel K. ;
Williams, Mathew R. ;
Smith, Craig R. ;
Svensson, Lars G. ;
Webb, John G. ;
Makkar, Raj R. ;
Fontana, Gregory P. ;
Dewey, Todd M. ;
Thourani, Vinod H. ;
Pichard, Augusto D. ;
Fischbein, Michael ;
Szeto, Wilson Y. ;
Lim, Scott ;
Greason, Kevin L. ;
Teirstein, Paul S. ;
Malaisrie, S. Chris ;
Douglas, Pamela S. ;
Hahn, Rebecca T. ;
Whisenant, Brian ;
Zajarias, Alan ;
Wang, Duolao ;
Akin, Jodi J. ;
Anderson, William N. ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) :1686-1695
[8]   A multi-centre additive and logistic risk model for in-hospital mortality following aortic valve replacement [J].
Kuduvalli, Manoj ;
Grayson, Antony D. ;
Au, John ;
Grotte, Geir ;
Bridgewater, Ben ;
Fabri, Brian M. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 31 (04) :607-613
[9]   Clinical experience with the ATS 3f Enable® Sutureless Bioprosthesis [J].
Martens, Sven ;
Sadowski, Jerzy ;
Eckstein, Friedrich S. ;
Bartus, Krzysztof ;
Kapelak, Boguslaw ;
Sievers, Hans-Hinrich ;
Schlensak, Christian ;
Carrel, Thierry ;
Suwalski, P. ;
Alfieri, O. ;
Myken, P. ;
Bogers, A. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (03) :749-755
[10]  
Sadowski J, 2009, KARDIOL POL, V67, P956