Simultaneous spectrophotometric determination of crystal violet and malachite green in water samples using partial least squares regression and central composite design after preconcentration by dispersive solid-phase extraction

被引:23
|
作者
Razi-Asrami, Mahboobeh [1 ]
Ghasemi, Jahan B. [2 ]
Amiri, Nayereh [3 ]
Sadeghi, Seyed Jamal [1 ]
机构
[1] KN Toosi Univ Technol, Fac Chem, Tehran, Iran
[2] Univ Tehran, Fac Chem, Tehran, Iran
[3] Kharazmi Univ, Fac Chem, Tehran, Iran
关键词
Crystal violet; Malachite green; Graphene oxide; Simultaneous determination; PLS; AQUEOUS-SOLUTION; DYE REMOVAL; MULTIVARIATE OPTIMIZATION; LIQUID-CHROMATOGRAPHY; BETA-CYCLODEXTRIN; ACTIVATED CARBON; METHYLENE-BLUE; GRAPHENE OXIDE; COLOR REMOVAL; CATIONIC DYES;
D O I
10.1007/s10661-017-5898-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, a simple, fast, and inexpensive method is introduced for the simultaneous spectrophotometric determination of crystal violet (CV) and malachite green (MG) contents in aquatic samples using partial least squares regression (PLS) as a multivariate calibration technique after preconcentration by graphene oxide (GO). The method was based on the sorption and desorption of analytes onto GO and direct determination by ultraviolet-visible spectrophotometric techniques. GO was synthesized according to Hummers method. To characterize the shape and structure of GO, FT-IR, SEM, and XRD were used. The effective factors on the extraction efficiency such as pH, extraction time, and the amount of adsorbent were optimized using central composite design. The optimum values of these factors were 6, 15 min, and 12 mg, respectively. The maximum capacity of GO for the adsorption of CV and MG was 63.17 and 77.02 mg g(-1), respectively. Preconcentration factors and extraction recoveries were obtained and were 19.6, 98% for CVand 20, 100% for MG, respectively. LOD and linear dynamic ranges for CVand MG were 0.009, 0.03-0.3, 0.015, and 0.05-0.5 (mu g mL(-1)), respectively. The intra-day and inter-day relative standard deviations were 1.99 and 0.58 for CV and 1.69 and 3.13 for MG at the concentration level of 50 ng mL(-1), respectively. Finally, the proposed DSPE/PLS method was successfully applied for the simultaneous determination of the trace amount of CV and MG in the real water samples.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Magnetic carbon nanotube composite for the preconcentration of parabens from water and urine samples using dispersive solid phase extraction
    Pastor-Belda, Marta
    Marin-Soler, Lidia
    Campillo, Natalia
    Vinas, Pilar
    Hernandez-Cordoba, Manuel
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1564 : 102 - 109
  • [32] Magnetic-Nanoparticle-Based Dispersive Micro-Solid Phase Extraction for the Determination of Crystal Violet in Environmental Water Samples
    Shojaei, Siroos
    Rahmani, Mashaallah
    Khajeh, Mostafa
    Abbasian, Ahmad Reza
    CHEMISTRYSELECT, 2021, 6 (19): : 4782 - 4790
  • [33] Solid-phase UV spectroscopic multisensor for the simultaneous determination of caffeine, dimenhydrinate and acetaminophen by using partial least squares multicalibration
    Cañada, MJA
    Reguera, MIP
    Díaz, AM
    Capitán-Vallvey, LF
    TALANTA, 1999, 49 (03) : 691 - 701
  • [34] Dispersive Solid-Phase Extraction Using Magnetic Carbon Nanotube Composite for the Determination of Emergent Mycotoxins in Urine Samples
    Arroyo-Manzanares, Natalia
    Penalver-Soler, Rosa
    Campillo, Natalia
    Vinas, Pilar
    TOXINS, 2020, 12 (01)
  • [35] Simultaneous spectrofluorimetric determination of paracetamol and caffeine in pharmaceutical preparations in solid-phase using partial least squares multivariate calibration
    Moreira, AB
    Dias, ILT
    Neto, GO
    Zagatto, EAG
    Kubota, LT
    ANALYTICAL LETTERS, 2006, 39 (02) : 349 - 360
  • [36] Optimization of solid phase dispersive field-assisted ultrasonication for the extraction of auramine O and crystal violet dyes using central composite design
    Pourebrahim, Faezeh
    Ghaedi, Mehrorang
    Dashtian, Kheibar
    Kheirandish, Shadi
    Goudarzi, Alireza
    APPLIED ORGANOMETALLIC CHEMISTRY, 2018, 32 (03)
  • [37] Cloud point extraction and simultaneous spectrophotometric determination of V(V), Co(II) and Cu(II) ions in water samples by 5-Br-PADAP using partial least squares regression
    Jian Deng
    Kaihui Huang
    Lin An
    Canhui Hu
    Saiqin Ju
    Ni Xiao
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 300 : 835 - 842
  • [38] Dispersive solid-phase extraction for determination of fast green and erythrosine dyes in environmental water samples using Zein bio-nanoparticles
    Hassan, Bayan
    Hadi, Hind
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024, 104 (17) : 5787 - 5802
  • [39] In situ preconcentration method for iron(II) in environmental water samples using solid phase extraction followed by spectrophotometric determination
    Okumura, M
    Seike, Y
    Fujinaga, K
    Hirao, K
    ANALYTICAL SCIENCES, 1997, 13 (02) : 231 - 235
  • [40] Cloud point extraction and simultaneous spectrophotometric determination of V(V), Co(II) and Cu(II) ions in water samples by 5-Br-PADAP using partial least squares regression
    Deng, Jian
    Huang, Kaihui
    An, Lin
    Hu, Canhui
    Ju, Saiqin
    Xiao, Ni
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (02) : 835 - 842