Effects of scanning parameters reduction in dental radiographs on image quality and diagnostic performance: A randomised controlled trial

被引:1
作者
Ghazali, Liyana [1 ]
Mohd Yusof, Mohd Yusmiaidil Putera [2 ]
Norman, Noraina Hafizan [1 ]
机构
[1] Univ Teknol MARA, Ctr Paediat Dent & Orthodont Studies, Fac Dent, Sungai Buloh 47000, Selangor, Malaysia
[2] Univ Teknol MARA, Ctr Oral & Maxillofacial Diagnost & Med Studies, Fac Dent, Sungai Buloh, Selangor, Malaysia
关键词
panoramic radiography; diagnostic imaging; radiation dosage; image quality; DOSE REDUCTION; ERRORS;
D O I
10.1177/1465312520971641
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate the effect of reducing scanning parameters of digital dental panoramic tomogram (DPT) and lateral cephalometric (LC) radiographs on quality and diagnostic performance of the images. Design: Single-centre prospective two-arm parallel randomised controlled trial. Setting: Orthodontic Clinic, Faculty of Dentistry, Universiti Teknologi MARA, Selangor, Malaysia. Participants: Adult orthodontic patients aged 18-35 years, indicated for DPT and LC, who were fit and healthy with a body mass index of 18.5-25.0, not contraindicated to radiographic examination, not pregnant, and did not have a history of facial or skeletal abnormalities or bone diseases were included. Methods: Thirty-eight adult orthodontic patients were randomised into control and intervention groups. DPT and LC radiographs in the control group were obtained using standard scanning parameters as prescribed by the manufacturer using Orthopantomograph (R) OP300 by Instrumentarium. Scanning parameters in the intervention group were reduced by 60% for DPT (60 kV, 3.2 mA) and 30% for LC (85 kV, 8 mA). A five-point rating scale was used for the assessment of image quality. Images were evaluated for diagnostic performance by detection of anatomical landmarks. Mann-Whitney test was performed to compare the quality and diagnostic performance of the images and the observer agreement was assessed using the intraclass correlation coefficient (ICC). Results: For image quality, the control group produced slightly lower median scores (DPT 2.0, LC 2.0) compared to the intervention group (DPT 2.0, LC 3.0). For diagnostic performance, both groups showed similar median scores (DPT 21.0, LC 32.0). The differences between control and intervention groups for both modalities were not statistically significant. The average scores for intra-observer agreement were excellent (ICC 0.917) and inter-observer agreement was good (ICC 0.822). Conclusion: Minimising radiation exposure by reducing scanning parameters on digital DPT by 60% and LC by 30% on Intsrumentarium 300 OP did not affect the quality and diagnostic performance of the images. Thus, scanning parameters on digital DPT and LC should be reduced when taking radiographs.
引用
收藏
页码:5 / 12
页数:8
相关论文
共 27 条
[1]  
Alkurt Meryem Toraman, 2008, J Contemp Dent Pract, V9, P34
[2]   Randomized controlled trial: the gold standard or an unobtainable fallacy? [J].
Bondemark, Lars ;
Ruf, Sabine .
EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (05) :457-461
[3]  
Celik I, 2003, J CONT DENT PRACTICE, V4, P19
[4]   Genotoxic effects of X-rays on keratinized mucosa cells during panoramic dental radiography [J].
Cerqueira, E. M. M. ;
Meireles, J. R. C. ;
Lopes, M. A. ;
Junqueira, V. C. ;
Gomes-Filho, Is ;
Trindade, S. ;
Machado-Santelli, G. M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (07) :398-403
[5]  
Cobourne M., 2016, HDB ORTHODONTICS, V2nd
[6]   Effect of dose reduction in digital dental panoramic radiography on image quality [J].
Dannewitz, B ;
Hassfeld, S ;
Eickholz, P ;
Mühling, J .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (01) :50-55
[7]   Positioning errors and quality assessment in panoramic radiography [J].
Dhillon, Manu ;
Raju, Srinivasa M. ;
Verma, Sankalp ;
Tomar, Divya ;
Mohan, Raviprakash S. ;
Lakhanpal, Manisha ;
Krishnamoorthy, Bhuvana .
IMAGING SCIENCE IN DENTISTRY, 2012, 42 (04) :207-212
[8]   Randomization and allocation concealment: a practical guide for researchers [J].
Doig, GS ;
Simpson, F .
JOURNAL OF CRITICAL CARE, 2005, 20 (02) :187-191
[9]   Effects of dose reduction on the detectability of standardized radiolucent lesions in digital panoramic radiography [J].
Dula, K ;
Sanderink, G ;
van der Stelt, PF ;
Mini, R ;
Buser, D .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 86 (02) :227-233
[10]   Organ doses and subjective image quality of indirect digital panoramic radiography [J].
Gijbels, F ;
Sanderink, G ;
Serhal, CB ;
Pauwels, H ;
Jacobs, R .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (06) :308-313