Purpose of review Cardiac output (GO) and other flow-based hemodynamic variables have become increasingly important to guide treatment of patients undergoing major surgery with expected fluid shifts in the operating room as well as critically ill ICU patients. Established techniques such as pulmonary artery thermodilution, however, might not be justified in all of these patients. As arterial access is commonly available, less-invasive arterial pressure waveform-based CO devices are becoming more and more popular. Recent findings Many studies dealing with arterial pressure waveform-based CO have emerged in recent years providing additional information with regard to accuracy of the different commercially available devices. Furthermore, methods of comparative GO studies have been recently brought into question. Summary Although there are differences in invasiveness and the need for external calibration, all available devices provide parameters for enhanced hemodynamic monitoring. Initial validation studies of the more established techniques such as the pulse contour cardiac output (PiCCO) or LiDCO were recently met with less enthusiasm, whereas the initially disappointing validation studies of the FloTrac/Vigileo device had encouraging results after software updates. The pressure recording analytical method (PRAM) technique has not so far been sufficiently evaluated to be able to come to a conclusion. Further investigation is required with regard to the ability of the arterial pressure waveform-based methods to guide goal-directed therapy.
引用
收藏
页码:804 / 808
页数:5
相关论文
共 47 条
[1]   Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model [J].
Bajorat, J ;
Hofmockel, R ;
Vagts, DA ;
Janda, M ;
Pohl, B ;
Beck, C ;
Noeldge-Schomburg, G .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (01) :23-30
[2]   The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration [J].
Bein, Berthold ;
Meybohm, Patrick ;
Cavus, Erol ;
Renner, Jochen ;
Tonner, Peter H. ;
Steinfath, Markus ;
Scholz, Jens ;
Doerges, Volker .
ANESTHESIA AND ANALGESIA, 2007, 105 (01) :107-113
[3]   When to recalibrate the PiCCO™? From a physiological point of view, the answer is simple [J].
Bendjelid, K. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (05) :689-690
[4]   Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient [J].
Bernstein, Donald P. .
OBESITY SURGERY, 2008, 18 (08) :1015-1021
[5]   Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery [J].
Biancofiore, G. ;
Critchley, L. A. H. ;
Lee, A. ;
Bindi, L. ;
Bisa, M. ;
Esposito, M. ;
Meacci, L. ;
Mozzo, R. ;
DeSimone, P. ;
Urbani, L. ;
Filipponi, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (01) :47-54
[6]   Perioperative management and monitoring in anaesthesia [J].
Buhre, W ;
Rossaint, R .
LANCET, 2003, 362 (9398) :1839-1846
[7]   Assessment of cardiac output in children: A comparison between the pressure recording analytical method and Doppler echocardiogyaphy [J].
Calamandrei, Marco ;
Mirabile, Lorenzo ;
Muschetta, Stefania ;
Gensini, Gian Franco ;
De Simone, Luciano ;
Romano, Salvatore M. .
PEDIATRIC CRITICAL CARE MEDICINE, 2008, 9 (03) :310-312
[8]   Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique [J].
Cecconi, M. ;
Dawson, D. ;
Grounds, R. M. ;
Rhodes, A. .
INTENSIVE CARE MEDICINE, 2009, 35 (03) :498-504
[9]   Methodologies for assessing agreement between two methods of clinical measurement: are we as good as we think we are? [J].
Cecconi, Maurizio ;
Grounds, Michael ;
Rhodes, Andrew .
CURRENT OPINION IN CRITICAL CARE, 2007, 13 (03) :294-296
[10]   Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output [J].
Cecconi, Maurizio ;
Rhodes, Andrew ;
Poloniecki, Jan ;
Della Rocca, Giorgio ;
Grounds, R. Michael .
CRITICAL CARE, 2009, 13 (01)