Device for online monitoring of insulation faults in high-voltage switchgears

被引:8
|
作者
Song, Jiajia [1 ,2 ]
Zhang, Jinbo [1 ,2 ]
Fan, Xinnan [1 ,2 ]
机构
[1] Hohai Univ, Coll IoT Engn, Changzhou 213022, Jiangsu, Peoples R China
[2] Jiangsu Key Lab Power Transmiss & Distribut Equip, Changzhou, Jiangsu, Peoples R China
关键词
Partial discharge; pulse current method; O-3; detection;
D O I
10.1177/1550147721999284
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Partial discharges are the major cause of deterioration in the insulation characteristics of switchgears. Therefore, timely detection of partial discharge in switchgear and potential insulation faults is an urgent problem that needs to be addressed in the power supervision industry. In this study, a device was proposed for online monitoring of high-voltage switchgears based on pulse current method and ozone (O-3) detection. The pulse current method obtains the PD signal by monitoring the phase holes on the switch indicator. Occurrence of a partial discharge in a certain phase leads to the production of a discharge pulse, which can be coupled out by a capacitive sensor. The current spectrum and the O-3 produced by partial discharge were processed via fast Fourier transform for accurate diagnosis of the occurrence of partial discharge and its severity in switchgears. The proposed method allows for convenient acquisition of the partial discharge signal, simple installation of the device, and realization with inexpensive sensors.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] DIAGNOSTIC TESTING OF HIGH-VOLTAGE MACHIEN INSULATION
    MILLER, R
    BLACK, IA
    HOGG, WK
    WOOD, JW
    MASON, JH
    SIMONS, JS
    IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1980, 127 (06): : 386 - 388
  • [42] CHARACTERIZATION OF HMWPE USED FOR HIGH-VOLTAGE INSULATION
    BARLOW, A
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1980, 15 (02): : 124 - 125
  • [43] Insulation monitoring on underground high-voltage lines using partial-discharge measurement
    Wittler, Michael
    Glueckauf-Forschungshefte, 2000, 61 (03): : 98 - 101
  • [44] Diagnosis and monitoring of high-voltage insulation using computerized analysis of partial discharge measurements
    Wahidabanu, RSD
    Panneerselvam, MA
    Udayakumar, K
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 1998, 23 (04): : 171 - 177
  • [45] Application of the method of monitoring partial discharges in insulation of high-voltage electrical machine stators
    Pavlenko, Sergey, V
    Kotov, Vladimir A.
    Golubev, Stanislav S.
    NAUKA I TEHNOLOGII TRUBOPROVODNOGO TRANSPORTA NEFTI I NEFTEPRODUKTOV-SCIENCE & TECHNOLOGIES-OIL AND OIL PRODUCTS PIPELINE TRANSPORTATION, 2019, 9 (05): : 568 - 575
  • [46] Experimental Study of High Energy Arcing Faults Using Medium Voltage Metalclad Switchgears
    Kabashima, Hajime
    Kasahara, Fumio
    NUCLEAR TECHNOLOGY, 2019, 205 (05) : 694 - 707
  • [47] An Adaptive Denoising Algorithm for Online Condition Monitoring of High-Voltage Power Equipment
    Hussain, Amjad
    Ahmed, Zeeshan
    Shafiq, Muhammad
    Zaher, Ashraf
    Rashid, Zeeshan
    Lehtonen, Matti
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2020, 48 (9-10) : 1036 - 1048
  • [48] High-voltage insulation of a high-power pulse transformer
    Ratakhin N.A.
    Fedushchak V.F.
    Russian Physics Journal, 1999, 42 (12) : 996 - 1000
  • [49] PROTECTIVE DEVICE FOR HIGH-VOLTAGE SOURCES OF ACCELERATING VOLTAGE
    BALABUKH, AI
    SHPAGIN, AV
    LIVSHITS, EG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1983, 26 (03) : 716 - 717
  • [50] MECHANICAL DEGRADATION OF HIGH-VOLTAGE ROTATING MACHINE INSULATION
    MITSUI, H
    YOSHIDA, K
    INOUE, Y
    KAWAHARA, K
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1981, 16 (04): : 351 - 359