Development of a Test System To Evaluate Procedures for Decontamination of Respirators Containing Viral Droplets

被引:51
作者
Vo, Evanly [1 ]
Rengasamy, Samy [1 ]
Shaffer, Ronald [1 ]
机构
[1] NIOSH, Natl Personal Protect Technol Lab, Pittsburgh, PA 15236 USA
关键词
TRANSMISSION; SARS; BACTERIOPHAGE-MS2; DISINFECTANTS; SIZE;
D O I
10.1128/AEM.00799-09
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The aim of this study was to develop a test system to evaluate the effectiveness of procedures for decontamination of respirators contaminated with viral droplets. MS2 coliphage was used as a surrogate for pathogenic viruses. A viral droplet test system was constructed, and the size distribution of viral droplets loaded directly onto respirators was characterized using an aerodynamic particle sizer. The sizes ranged from 0.5 to 15 mu m, and the sizes of the majority of the droplets were the range from 0.74 to 3.5 mu m. The results also showed that the droplet test system generated similar droplet concentrations (particle counts) at different respirator locations. The test system was validated by studying the relative efficiencies of decontamination of sodium hypochlorite (bleach) and UV irradiation with droplets containing MS2 virus on filtering facepiece respirators. It was hypothesized that more potent decontamination treatments would result in corresponding larger decreases in the number of viable viruses recovered from the respirators. Sodium hypochlorite doses of 2.75 to 5.50 mg/liter with a 10-min decontamination period resulted in approximately 3- to 4-log reductions in the level of MS2 coliphage. When higher sodium hypochlorite doses (>= 8.25 mg/liter) were used with the same contact time that was used for the dilute solutions containing 2.75 to 5.50 mg/liter, all MS2 was inactivated. For UV decontamination at a wavelength of 254 nm, an approximately 3-log reduction in the level of MS2 virus was achieved with dose of 4.32 J/cm(2) (3 h of contact time with a UV intensity of 0.4 mW/cm(2)), while with higher doses of UV irradiation (>= 7.20 J/cm(2); UV intensity, 0.4 mW/cm(2); contact times, >= 5 h), all MS2 was inactivated. These findings may lead to development of a standard method to test decontamination of respirators challenged by viral droplets.
引用
收藏
页码:7303 / 7309
页数:7
相关论文
共 32 条
[1]  
[Anonymous], INT REC FAC RESP US
[2]  
[Anonymous], 1998, STAND METH EX WAT WA, V20th
[3]  
*ASTM INT, 2002, E105397 ASTM INT
[4]  
*ASTM INT, 2002, E105296 ASTM INT
[5]  
Bailar JC., 2006, Reusability of Facemasks during an Influenza Pandemic
[6]  
*CDCP, 2007, GUID IS PREC HOSP
[7]  
Chin J., 2000, CONTROL COMMUNICABLE, V17th
[8]   Possible SARS coronavirus transmission during cardiopulmonary resuscitation [J].
Christian, MD ;
Loutfy, M ;
McDonald, C ;
Martinez, KF ;
Ofner, M ;
Wong, T ;
Wallington, T ;
Gold, WL ;
Mederski, B ;
Green, K ;
Low, DE .
EMERGING INFECTIOUS DISEASES, 2004, 10 (02) :287-293
[9]   THE SIZE AND THE DURATION OF AIR-CARRIAGE OF RESPIRATORY DROPLETS AND DROPLET-NUCLEI [J].
DUGUID, JP .
JOURNAL OF HYGIENE, 1946, 44 (06) :471-479
[10]  
Dwosh HA, 2003, CAN MED ASSOC J, V168, P1415